[墨西哥耐力运动员最大运动测试期间的心肺动力学]。

J Padilla, E Martínez, G Olvera, P Ojeda Cruz, D Caudillo Pérez
{"title":"[墨西哥耐力运动员最大运动测试期间的心肺动力学]。","authors":"J Padilla,&nbsp;E Martínez,&nbsp;G Olvera,&nbsp;P Ojeda Cruz,&nbsp;D Caudillo Pérez","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To search for cardiopulmonary (CP) kinetic and dynamic differences between Mexican resistance athletes (RES = 10) and non athletes (NON = 19).</p><p><strong>Method: </strong>From the expired volume (Ve), measured by an open circuit spirometry, we calculated both VO2 and VCO2 during stress test while the volunteer pedalled seated on an electronic cycloergometer that started at 50 W.2 min-1 followed by increments of 25 W.2 min-1 each, until VO2máx was reached. The exercise transient time course (min) response (VO2, VCO2, Ve and heart rate, HR; and also O2 pulse, PulO2) was transformed to seconds and modelled by computer using linear regression technique by the interactive minimum squares method, and the mean response time (MRT) was used as an overall kinetic CP parameter.</p><p><strong>Results: </strong>The transient MRTs for VO2, VCO2 and Ve were slow in RES compared to NON. While the transient CP dynamics in NON lasted MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve; the RES: both MRT_PulO2 and MRT_HR shifted to the right ((MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve). The relationships between the best sport profit mean velocity and both the MRT_VO2, MRT_VCO2 and MRT_PulO2 (GEK = gas exchange kinetics) showed fast_RES and slow_GEK, and slow_RES and fast_GEK.</p><p><strong>Conclusion: </strong>The transient CP kinetics was slow in RES compared NON. It is possible to distinguish cardiopulmonary kinetic differences among resistance athletes holding different sport profiles.</p>","PeriodicalId":75556,"journal":{"name":"Archivos del Instituto de Cardiologia de Mexico","volume":"70 3","pages":"268-84"},"PeriodicalIF":0.0000,"publicationDate":"2000-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Cardiopulmonary dynamics during a maximal exertion test in Mexican endurance athletes].\",\"authors\":\"J Padilla,&nbsp;E Martínez,&nbsp;G Olvera,&nbsp;P Ojeda Cruz,&nbsp;D Caudillo Pérez\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To search for cardiopulmonary (CP) kinetic and dynamic differences between Mexican resistance athletes (RES = 10) and non athletes (NON = 19).</p><p><strong>Method: </strong>From the expired volume (Ve), measured by an open circuit spirometry, we calculated both VO2 and VCO2 during stress test while the volunteer pedalled seated on an electronic cycloergometer that started at 50 W.2 min-1 followed by increments of 25 W.2 min-1 each, until VO2máx was reached. The exercise transient time course (min) response (VO2, VCO2, Ve and heart rate, HR; and also O2 pulse, PulO2) was transformed to seconds and modelled by computer using linear regression technique by the interactive minimum squares method, and the mean response time (MRT) was used as an overall kinetic CP parameter.</p><p><strong>Results: </strong>The transient MRTs for VO2, VCO2 and Ve were slow in RES compared to NON. While the transient CP dynamics in NON lasted MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve; the RES: both MRT_PulO2 and MRT_HR shifted to the right ((MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve). The relationships between the best sport profit mean velocity and both the MRT_VO2, MRT_VCO2 and MRT_PulO2 (GEK = gas exchange kinetics) showed fast_RES and slow_GEK, and slow_RES and fast_GEK.</p><p><strong>Conclusion: </strong>The transient CP kinetics was slow in RES compared NON. It is possible to distinguish cardiopulmonary kinetic differences among resistance athletes holding different sport profiles.</p>\",\"PeriodicalId\":75556,\"journal\":{\"name\":\"Archivos del Instituto de Cardiologia de Mexico\",\"volume\":\"70 3\",\"pages\":\"268-84\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos del Instituto de Cardiologia de Mexico\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos del Instituto de Cardiologia de Mexico","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨墨西哥抗阻运动员(RES = 10)与非运动员(non = 19)的心肺动力学和动力学差异。方法:通过开路肺活量计测量的到期体积(Ve),我们计算了志愿者在压力测试期间的VO2和VCO2,而志愿者坐在电子循环计量器上蹬车,从50w .2 min-1开始,然后每次增加25w .2 min-1,直到达到VO2máx。运动短暂时间过程(min)反应(VO2, VCO2, Ve和心率,HR;将O2脉冲PulO2转换为秒,采用交互最小二乘法线性回归技术进行计算机建模,并以平均响应时间(MRT)作为总体动力学CP参数。结果:RES组VO2、VCO2和Ve的瞬时mrt较NON组慢。而非瞬态CP动态持续MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve;(MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve)。最佳运动利润平均速度与MRT_VO2、MRT_VCO2和MRT_PulO2 (GEK =气体交换动力学)的关系为fast_RES和slow_GEK, slow_RES和fast_GEK。结论:RES组瞬时CP动力学较NON组慢。这是有可能区分心肺动力学的差异阻力运动员持有不同的运动档案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Cardiopulmonary dynamics during a maximal exertion test in Mexican endurance athletes].

Aim: To search for cardiopulmonary (CP) kinetic and dynamic differences between Mexican resistance athletes (RES = 10) and non athletes (NON = 19).

Method: From the expired volume (Ve), measured by an open circuit spirometry, we calculated both VO2 and VCO2 during stress test while the volunteer pedalled seated on an electronic cycloergometer that started at 50 W.2 min-1 followed by increments of 25 W.2 min-1 each, until VO2máx was reached. The exercise transient time course (min) response (VO2, VCO2, Ve and heart rate, HR; and also O2 pulse, PulO2) was transformed to seconds and modelled by computer using linear regression technique by the interactive minimum squares method, and the mean response time (MRT) was used as an overall kinetic CP parameter.

Results: The transient MRTs for VO2, VCO2 and Ve were slow in RES compared to NON. While the transient CP dynamics in NON lasted MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve; the RES: both MRT_PulO2 and MRT_HR shifted to the right ((MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve). The relationships between the best sport profit mean velocity and both the MRT_VO2, MRT_VCO2 and MRT_PulO2 (GEK = gas exchange kinetics) showed fast_RES and slow_GEK, and slow_RES and fast_GEK.

Conclusion: The transient CP kinetics was slow in RES compared NON. It is possible to distinguish cardiopulmonary kinetic differences among resistance athletes holding different sport profiles.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
相关文献
二甲双胍通过HDAC6和FoxO3a转录调控肌肉生长抑制素诱导肌肉萎缩
IF 8.9 1区 医学Journal of Cachexia, Sarcopenia and MusclePub Date : 2021-11-02 DOI: 10.1002/jcsm.12833
Min Ju Kang, Ji Wook Moon, Jung Ok Lee, Ji Hae Kim, Eun Jeong Jung, Su Jin Kim, Joo Yeon Oh, Sang Woo Wu, Pu Reum Lee, Sun Hwa Park, Hyeon Soo Kim
具有疾病敏感单倍型的非亲属供体脐带血移植后的1型糖尿病
IF 3.2 3区 医学Journal of Diabetes InvestigationPub Date : 2022-11-02 DOI: 10.1111/jdi.13939
Kensuke Matsumoto, Taisuke Matsuyama, Ritsu Sumiyoshi, Matsuo Takuji, Tadashi Yamamoto, Ryosuke Shirasaki, Haruko Tashiro
封面:蛋白质组学分析确定IRSp53和fastin是PRV输出和直接细胞-细胞传播的关键
IF 3.4 4区 生物学ProteomicsPub Date : 2019-12-02 DOI: 10.1002/pmic.201970201
Fei-Long Yu, Huan Miao, Jinjin Xia, Fan Jia, Huadong Wang, Fuqiang Xu, Lin Guo
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Arteriovenous fistulas]. [The foundations of medical ethics]. [Influence of the pericardium in the pathophysiology of ventricular dysfunction in acute infarct of the right ventricle. Experimental study] . [Experience in 1,500 patients undergoing radiofrequency ablation in the treatment of tachycardias]. [Efficacy and safety of immediate-release niacin in patients with ischemic cardiopathy. Experience of the Instituto Nacional de Cardiología "Ignacio Chávez"].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1