机器人辅助与常规全膝关节置换术的比较:一项使用多参数定量三维CT评估对齐的对照尸体研究。

Q Medicine Computer Aided Surgery Pub Date : 2012-01-01 DOI:10.3109/10929088.2012.654408
Young-Wan Moon, Chul-Won Ha, Kwan-Hong Do, Chang-Young Kim, Jeong-Hoon Han, Sang-Eun Na, Choong-Hee Lee, Jae-Gyoon Kim, Youn-Soo Park
{"title":"机器人辅助与常规全膝关节置换术的比较:一项使用多参数定量三维CT评估对齐的对照尸体研究。","authors":"Young-Wan Moon,&nbsp;Chul-Won Ha,&nbsp;Kwan-Hong Do,&nbsp;Chang-Young Kim,&nbsp;Jeong-Hoon Han,&nbsp;Sang-Eun Na,&nbsp;Choong-Hee Lee,&nbsp;Jae-Gyoon Kim,&nbsp;Youn-Soo Park","doi":"10.3109/10929088.2012.654408","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning.</p><p><strong>Materials and methods: </strong>Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values.</p><p><strong>Results: </strong>In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p = 0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability.</p><p><strong>Conclusion: </strong>Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"17 2","pages":"86-95"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2012.654408","citationCount":"68","resultStr":"{\"title\":\"Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.\",\"authors\":\"Young-Wan Moon,&nbsp;Chul-Won Ha,&nbsp;Kwan-Hong Do,&nbsp;Chang-Young Kim,&nbsp;Jeong-Hoon Han,&nbsp;Sang-Eun Na,&nbsp;Choong-Hee Lee,&nbsp;Jae-Gyoon Kim,&nbsp;Youn-Soo Park\",\"doi\":\"10.3109/10929088.2012.654408\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning.</p><p><strong>Materials and methods: </strong>Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values.</p><p><strong>Results: </strong>In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p = 0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability.</p><p><strong>Conclusion: </strong>Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.</p>\",\"PeriodicalId\":50644,\"journal\":{\"name\":\"Computer Aided Surgery\",\"volume\":\"17 2\",\"pages\":\"86-95\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10929088.2012.654408\",\"citationCount\":\"68\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Aided Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10929088.2012.654408\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2012.654408","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 68

摘要

一个功能性的全膝关节置换术必须很好地对齐,这意味着它应该沿着机械轴和正确的轴向和旋转平面。不正确的对准会导致异常磨损、早期机械松动和髌骨问题。近来,在机器人辅助下的全膝关节置换术越来越受关注。本研究旨在确定机器人辅助全膝关节置换术在植入物定位精度方面是否优于传统手术方法。材料和方法:在10具尸体上进行了20例膝关节置换术,包括10例机器人辅助手术和10例常规手术。两位经验丰富的外科医生进行了手术。每具尸体上的两种手术都是由同一名外科医生进行的。首先进行哪一种手术的选择是随机的。植入假体后,通过三维CT扫描测量机械轴偏差、股骨冠状角、胫骨冠状角、股骨矢状角、胫骨矢状角、股骨旋转对中。然后将这些变量与术前计划值进行比较。结果:在接受机器人辅助手术的膝关节中,机械轴偏差范围为-1.94°至2.13°(平均:-0.21°),股骨冠状角范围为88.08°至90.99°(平均:89.81°),胫骨冠状角范围为89.01°至92.36°(平均:90.42°),胫骨矢状角范围为81.72°至86.24°(平均:83.20°),股骨旋转对齐范围为0.02°至1.15°(平均:0.52°)。在接受常规手术的膝关节中,机械轴偏差范围为-3.19°至3.84°(平均:-0.48°),股骨冠状角范围为88.36°至92.29°(平均:90.50°),胫骨冠状角范围为88.15°至91.51°(平均:89.83°),胫骨矢状角范围为80.06°至87.34°(平均:84.50°),股骨旋转对齐范围为0.32°至4.13°(平均:2.76°)。在常规膝关节置换术组中,机械轴偏差在3°内翻/外翻范围外有2例异常值。与传统手术相比,机器人辅助膝关节置换术的股骨旋转对齐效果显著优于传统手术(p = 0.006)。在其他变量方面,机器人辅助和传统全膝关节置换术之间没有统计学上的显著差异。所有测量结果均显示出较高的观察者内部和观察者之间的信度。结论:机器人辅助全膝关节置换术的三维CT矢状面和冠状面扫描精度高。特别是,与传统手术相比,机器人辅助技术在股骨旋转对准方面表现出更好的准确性,尽管进行手术的外科医生比机器人辅助手术更有经验和熟悉传统方法。由此可以得出结论,机器人辅助全膝关节置换术优于常规全膝关节置换术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.

Introduction: A functional total knee replacement has to be well aligned, which implies that it should lie along the mechanical axis and in the correct axial and rotational planes. Incorrect alignment will lead to abnormal wear, early mechanical loosening, and patellofemoral problems. There has been increased interest of late in total knee arthroplasty with robotic assistance. This study was conducted to determine whether robot-assisted total knee arthroplasty is superior to the conventional surgical method with regard to the precision of implant positioning.

Materials and methods: Twenty knee replacements, comprising ten robot-assisted procedures and ten conventional operations, were performed on ten cadavers. Two experienced surgeons performed the surgeries. Both procedures on each cadaver were performed by the same surgeon. The choice of which procedure was to be performed first was randomized. Following implantation of the prosthesis, the mechanical axis deviation, femoral coronal angle, tibial coronal angle, femoral sagittal angle, tibial sagittal angle, and femoral rotational alignment were measured via 3D CT scanning. These variables were then compared with the preoperatively planned values.

Results: In the knees that underwent robot-assisted surgery, the mechanical axis deviation ranged from -1.94° to 2.13° (mean: -0.21°), the femoral coronal angle from 88.08° to 90.99° (mean: 89.81°), the tibial coronal angle from 89.01° to 92.36° (mean: 90.42°), the tibial sagittal angle from 81.72° to 86.24° (mean: 83.20°), and the femoral rotational alignment from 0.02° to 1.15° (mean: 0.52°) in relation to the transepicondylar axis. In the knees that underwent conventional surgery, the mechanical axis deviation ranged from -3.19° to 3.84° (mean: -0.48°), the femoral coronal angle from 88.36° to 92.29° (mean: 90.50°), the tibial coronal angle from 88.15° to 91.51° (mean: 89.83°), the tibial sagittal angle from 80.06° to 87.34° (mean: 84.50°), and the femoral rotational alignment from 0.32° to 4.13° (mean: 2.76°) in relation to the transepicondylar axis. In the conventional knee replacement group, there were two instances of outliers outside the range of 3° varus/valgus for the mechanical axis deviation. The robot-assisted knee replacements showed significantly superior femoral rotational alignment results compared with conventional surgery (p = 0.006). There was no statistically significant difference between robot-assisted and conventional total knee arthroplasty with regard to the other variables. All the measurements showed high intra-observer and inter-observer reliability.

Conclusion: Robot-assisted total knee arthroplasty showed excellent precision in the sagittal and coronal planes of the 3D CT scan. In particular, the robot-assisted technique showed better accuracy in femoral rotational alignment compared to the conventional surgery, despite the fact that the surgeons who performed the operations were more experienced and familiar with the conventional method than with robot-assisted surgery. It can thus be concluded that robot-assisted total knee arthroplasty is superior to conventional total knee arthroplasty.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Computer Aided Surgery
Computer Aided Surgery 医学-外科
CiteScore
0.75
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.
期刊最新文献
One-step reconstruction with a 3D-printed, biomechanically evaluated custom implant after complex pelvic tumor resection. Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images. Numerical simulation of blood flow and plaque progression in carotid-carotid bypass patient specific case. Towards the clinical integration of an image-guided navigation system for percutaneous liver tumor ablation using freehand 2D ultrasound images. A comparison of two surgical approaches in functional neurosurgery: individualized versus conventional stereotactic frames.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1