Ivan Marintschev, Sascha Rausch, Albert Fujak, Kajetan Klos, Gunther O Hofmann, Florian Gras
{"title":"端帽骨过度生长的股钉移除术:一种导航和插管微创技术。","authors":"Ivan Marintschev, Sascha Rausch, Albert Fujak, Kajetan Klos, Gunther O Hofmann, Florian Gras","doi":"10.3109/10929088.2012.741623","DOIUrl":null,"url":null,"abstract":"<p><p>Intramedullary nail removal can be demanding, especially in cases of implant breakage or bony overgrowth at the end-cap, if the exact insertion depth of the nail is neglected in the index surgery. In the presented case, two challenging nail removals were necessary. The first was performed in a re-nailing procedure due to a pseudarthrosis with implant breakage, and the second was performed during hardware removal after fracture healing in a situation where there was deep intramedullary placement of the exchange nail. For the second implant removal a minimally invasive approach based on instrument placements over a navigated guide-wire was used to reduce the iatrogenic morbidity associated with an extensive open approach to the nail and to decrease the radiation exposure for the patient and the operating team.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"18 1-2","pages":"41-6"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2012.741623","citationCount":"1","resultStr":"{\"title\":\"Removal of a femoral nail with osseous overgrowth at the end-cap: A navigated and cannulated minimally invasive technique.\",\"authors\":\"Ivan Marintschev, Sascha Rausch, Albert Fujak, Kajetan Klos, Gunther O Hofmann, Florian Gras\",\"doi\":\"10.3109/10929088.2012.741623\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Intramedullary nail removal can be demanding, especially in cases of implant breakage or bony overgrowth at the end-cap, if the exact insertion depth of the nail is neglected in the index surgery. In the presented case, two challenging nail removals were necessary. The first was performed in a re-nailing procedure due to a pseudarthrosis with implant breakage, and the second was performed during hardware removal after fracture healing in a situation where there was deep intramedullary placement of the exchange nail. For the second implant removal a minimally invasive approach based on instrument placements over a navigated guide-wire was used to reduce the iatrogenic morbidity associated with an extensive open approach to the nail and to decrease the radiation exposure for the patient and the operating team.</p>\",\"PeriodicalId\":50644,\"journal\":{\"name\":\"Computer Aided Surgery\",\"volume\":\"18 1-2\",\"pages\":\"41-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10929088.2012.741623\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Aided Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10929088.2012.741623\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/11/26 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2012.741623","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/11/26 0:00:00","PubModel":"Epub","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
Removal of a femoral nail with osseous overgrowth at the end-cap: A navigated and cannulated minimally invasive technique.
Intramedullary nail removal can be demanding, especially in cases of implant breakage or bony overgrowth at the end-cap, if the exact insertion depth of the nail is neglected in the index surgery. In the presented case, two challenging nail removals were necessary. The first was performed in a re-nailing procedure due to a pseudarthrosis with implant breakage, and the second was performed during hardware removal after fracture healing in a situation where there was deep intramedullary placement of the exchange nail. For the second implant removal a minimally invasive approach based on instrument placements over a navigated guide-wire was used to reduce the iatrogenic morbidity associated with an extensive open approach to the nail and to decrease the radiation exposure for the patient and the operating team.
期刊介绍:
The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.