基于x线的假体设计颈椎运动学分析:Mobi C、Bryan、PCM和Prestige LP的分析。

Sung B Park, Ki J Kim, Yong J Jin, Hyun J Kim, Tae-A Jahng, Chun K Chung
{"title":"基于x线的假体设计颈椎运动学分析:Mobi C、Bryan、PCM和Prestige LP的分析。","authors":"Sung B Park,&nbsp;Ki J Kim,&nbsp;Yong J Jin,&nbsp;Hyun J Kim,&nbsp;Tae-A Jahng,&nbsp;Chun K Chung","doi":"10.1097/BSD.0b013e318288a923","DOIUrl":null,"url":null,"abstract":"<p><strong>Study design: </strong>A retrospective study.</p><p><strong>Objective: </strong>To identify significant kinematic changes in the cervical spine after cervical artificial disk replacement (ADR) using prostheses with diverse designs.</p><p><strong>Summary of background data: </strong>Various types of artificial disks are used for cervical ADR. However, few clinical studies with a follow-up of 2 or more years have reported on the change in the curvatures and range of motion (ROM) of the cervical spine after cervical ADR in relation to different designs.</p><p><strong>Methods: </strong>The cohort comprised 58 patients who underwent single-level cervical ADR for radiculopathy. The patients were divided into 4 groups according to the device they received: Mobi-C, Bryan, PCM, and Prestige LP. The radiographs of the cervical spine were obtained preoperatively and at 12, 24, and 36 months after surgery. Several kinematic parameters, including lordotic angles and ROM of the cervical spine, index level, and superior and inferior adjacent disk levels, were assessed preoperatively and at predefined follow-up time points.</p><p><strong>Results: </strong>Cervical sagittal lordosis in patients who received Bryan and PCM prostheses increased at the last follow-up period. The 4 patient groups showed a trend toward an increase of lordosis in the superior adjacent segment with time. The patients who received the Bryan device lost their preoperative lordotic angle at the inferior adjacent level. The ROM of the cervical spine in patients who received Bryan and PCM prostheses increased at the last follow-up compared with preoperative values. The incidence of adjacent segment degeneration in the Mobi-C, Bryan, Prestige LP, and PCM groups were 14.2%, 25%, 9.0%, and 7.6%, respectively.</p><p><strong>Conclusions: </strong>These results suggest preservation of sagittal ROM and increased superior adjacent segment kinematics, regardless of prosthesis design. Devices with an unconstrained design may not be beneficial to adjacent segment kinematics compared with semiconstrained prostheses.</p>","PeriodicalId":50043,"journal":{"name":"Journal of Spinal Disorders & Techniques","volume":"28 5","pages":"E291-7"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/BSD.0b013e318288a923","citationCount":"19","resultStr":"{\"title\":\"X-Ray-based Kinematic Analysis of Cervical Spine According to Prosthesis Designs: Analysis of the Mobi C, Bryan, PCM, and Prestige LP.\",\"authors\":\"Sung B Park,&nbsp;Ki J Kim,&nbsp;Yong J Jin,&nbsp;Hyun J Kim,&nbsp;Tae-A Jahng,&nbsp;Chun K Chung\",\"doi\":\"10.1097/BSD.0b013e318288a923\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Study design: </strong>A retrospective study.</p><p><strong>Objective: </strong>To identify significant kinematic changes in the cervical spine after cervical artificial disk replacement (ADR) using prostheses with diverse designs.</p><p><strong>Summary of background data: </strong>Various types of artificial disks are used for cervical ADR. However, few clinical studies with a follow-up of 2 or more years have reported on the change in the curvatures and range of motion (ROM) of the cervical spine after cervical ADR in relation to different designs.</p><p><strong>Methods: </strong>The cohort comprised 58 patients who underwent single-level cervical ADR for radiculopathy. The patients were divided into 4 groups according to the device they received: Mobi-C, Bryan, PCM, and Prestige LP. The radiographs of the cervical spine were obtained preoperatively and at 12, 24, and 36 months after surgery. Several kinematic parameters, including lordotic angles and ROM of the cervical spine, index level, and superior and inferior adjacent disk levels, were assessed preoperatively and at predefined follow-up time points.</p><p><strong>Results: </strong>Cervical sagittal lordosis in patients who received Bryan and PCM prostheses increased at the last follow-up period. The 4 patient groups showed a trend toward an increase of lordosis in the superior adjacent segment with time. The patients who received the Bryan device lost their preoperative lordotic angle at the inferior adjacent level. The ROM of the cervical spine in patients who received Bryan and PCM prostheses increased at the last follow-up compared with preoperative values. The incidence of adjacent segment degeneration in the Mobi-C, Bryan, Prestige LP, and PCM groups were 14.2%, 25%, 9.0%, and 7.6%, respectively.</p><p><strong>Conclusions: </strong>These results suggest preservation of sagittal ROM and increased superior adjacent segment kinematics, regardless of prosthesis design. Devices with an unconstrained design may not be beneficial to adjacent segment kinematics compared with semiconstrained prostheses.</p>\",\"PeriodicalId\":50043,\"journal\":{\"name\":\"Journal of Spinal Disorders & Techniques\",\"volume\":\"28 5\",\"pages\":\"E291-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1097/BSD.0b013e318288a923\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Spinal Disorders & Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/BSD.0b013e318288a923\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Spinal Disorders & Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BSD.0b013e318288a923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 19

摘要

研究设计:回顾性研究。目的:探讨不同设计的假体在颈椎人工椎间盘置换术(ADR)后颈椎明显的运动学变化。背景资料总结:各种类型的人工椎间盘用于颈椎不良反应。然而,很少有随访2年或更长时间的临床研究报道了不同设计的颈椎不良反应后颈椎弯曲度和活动范围的变化。方法:该队列包括58例因神经根病发生单级颈椎不良反应的患者。根据患者使用的设备分为Mobi-C组、Bryan组、PCM组和Prestige LP组。术前及术后12、24、36个月颈椎x线片。几个运动学参数,包括颈椎前凸角和关节活动度,指数水平,上下相邻椎间盘水平,在术前和预定随访时间点进行评估。结果:在最后随访期间,接受Bryan和PCM假体的患者颈椎矢状前凸增加。4组患者均表现出上邻段前凸程度随时间增加的趋势。接受Bryan装置的患者失去了术前下邻段的前凸角。与术前相比,接受Bryan和PCM假体的患者的颈椎ROM在最后一次随访时增加。Mobi-C、Bryan、Prestige LP和PCM组相邻节段退变的发生率分别为14.2%、25%、9.0%和7.6%。结论:结果表明,无论假体设计如何,矢状面ROM的保存和相邻节段运动的增加都是有效的。与半应变假肢相比,无约束设计的装置可能不利于相邻节段的运动学。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
X-Ray-based Kinematic Analysis of Cervical Spine According to Prosthesis Designs: Analysis of the Mobi C, Bryan, PCM, and Prestige LP.

Study design: A retrospective study.

Objective: To identify significant kinematic changes in the cervical spine after cervical artificial disk replacement (ADR) using prostheses with diverse designs.

Summary of background data: Various types of artificial disks are used for cervical ADR. However, few clinical studies with a follow-up of 2 or more years have reported on the change in the curvatures and range of motion (ROM) of the cervical spine after cervical ADR in relation to different designs.

Methods: The cohort comprised 58 patients who underwent single-level cervical ADR for radiculopathy. The patients were divided into 4 groups according to the device they received: Mobi-C, Bryan, PCM, and Prestige LP. The radiographs of the cervical spine were obtained preoperatively and at 12, 24, and 36 months after surgery. Several kinematic parameters, including lordotic angles and ROM of the cervical spine, index level, and superior and inferior adjacent disk levels, were assessed preoperatively and at predefined follow-up time points.

Results: Cervical sagittal lordosis in patients who received Bryan and PCM prostheses increased at the last follow-up period. The 4 patient groups showed a trend toward an increase of lordosis in the superior adjacent segment with time. The patients who received the Bryan device lost their preoperative lordotic angle at the inferior adjacent level. The ROM of the cervical spine in patients who received Bryan and PCM prostheses increased at the last follow-up compared with preoperative values. The incidence of adjacent segment degeneration in the Mobi-C, Bryan, Prestige LP, and PCM groups were 14.2%, 25%, 9.0%, and 7.6%, respectively.

Conclusions: These results suggest preservation of sagittal ROM and increased superior adjacent segment kinematics, regardless of prosthesis design. Devices with an unconstrained design may not be beneficial to adjacent segment kinematics compared with semiconstrained prostheses.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.16
自引率
0.00%
发文量
0
审稿时长
3 months
期刊介绍: Journal of Spinal Disorders & Techniques features peer-reviewed original articles on diagnosis, management, and surgery for spinal problems. Topics include degenerative disorders, spinal trauma, diagnostic anesthetic blocks, metastatic tumor spinal replacements, management of pain syndromes, and the use of imaging techniques in evaluating lumbar spine disorder. The journal also presents thoroughly documented case reports.
期刊最新文献
Crystal structure of an inorganic pyrophosphatase from Chlamydia trachomatis D/UW-3/Cx. Effect of Preoperative Tracheal Stretch Exercise on Anterior Cervical Spine Surgery: A Retrospective Study. Management and Outcomes of Cerebrospinal Fluid Leak Associated With Anterior Decompression for Cervical Ossification of the Posterior Longitudinal Ligament With or Without Dural Ossification. The Efficiency of Zero-profile Implant in Anterior Cervical Discectomy Fusion: A Prospective Controlled Long-term Follow-up Study. Transforaminal Lumbar Interbody Fusion in Degenerative Disk Disease and Spondylolisthesis Grade I: Minimally Invasive Versus Open Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1