mri驱动心房颤动导管消融的任务空间运动规划。

Tipakorn Greigarn, M Cenk Cavuşoğlu
{"title":"mri驱动心房颤动导管消融的任务空间运动规划。","authors":"Tipakorn Greigarn,&nbsp;M Cenk Cavuşoğlu","doi":"10.1109/IROS.2014.6943047","DOIUrl":null,"url":null,"abstract":"<p><p>This paper presents a motion planning algorithm for Magnetic Resonance Imaging (MRI) actuated catheters for catheter ablation of atrial fibrillation. The MRI-actuated catheters is a new robotic catheter concept which utilizes MRI for remote steering and guidance. Magnetic moments generated by a set of coils wound near the tip are used to steer the catheter under MRI scanner magnetic field. The catheter during an ablation procedure is modeled as a constrained robotic manipulator with flexible joints, and the proposed motion-planning algorithm calculates a sequence of magnetic moments based on the manipulator model to move the tip of the catheter along a predefined trajectory on the surface of the left atrium. The difficulties in motion planning of the catheter are due to kinematic redundancy and underactuation. The proposed motion planning algorithm overcomes the challenges by operating in the task space instead of the configuration space. The catheter is then regulated around this nominal trajectory using feedback control to reduce the effect of uncertainties.</p>","PeriodicalId":74523,"journal":{"name":"Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems","volume":"2014 ","pages":"3476-3482"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/IROS.2014.6943047","citationCount":"24","resultStr":"{\"title\":\"Task-Space Motion Planning of MRI-Actuated Catheters for Catheter Ablation of Atrial Fibrillation.\",\"authors\":\"Tipakorn Greigarn,&nbsp;M Cenk Cavuşoğlu\",\"doi\":\"10.1109/IROS.2014.6943047\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper presents a motion planning algorithm for Magnetic Resonance Imaging (MRI) actuated catheters for catheter ablation of atrial fibrillation. The MRI-actuated catheters is a new robotic catheter concept which utilizes MRI for remote steering and guidance. Magnetic moments generated by a set of coils wound near the tip are used to steer the catheter under MRI scanner magnetic field. The catheter during an ablation procedure is modeled as a constrained robotic manipulator with flexible joints, and the proposed motion-planning algorithm calculates a sequence of magnetic moments based on the manipulator model to move the tip of the catheter along a predefined trajectory on the surface of the left atrium. The difficulties in motion planning of the catheter are due to kinematic redundancy and underactuation. The proposed motion planning algorithm overcomes the challenges by operating in the task space instead of the configuration space. The catheter is then regulated around this nominal trajectory using feedback control to reduce the effect of uncertainties.</p>\",\"PeriodicalId\":74523,\"journal\":{\"name\":\"Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems\",\"volume\":\"2014 \",\"pages\":\"3476-3482\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/IROS.2014.6943047\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IROS.2014.6943047\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IROS.2014.6943047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

提出了一种用于心房颤动导管消融的磁共振成像(MRI)驱动导管运动规划算法。MRI驱动导尿管是一种新的机器人导尿管概念,它利用MRI进行远程转向和引导。在尖端附近缠绕的一组线圈产生的磁矩用于在MRI扫描仪的磁场下引导导管。将导管消融过程建模为具有柔性关节的受限机械臂,提出的运动规划算法基于机械臂模型计算一系列磁矩,使导管尖端沿左心房表面预定轨迹移动。导管运动规划的困难是由于运动冗余和欠驱动。本文提出的运动规划算法通过在任务空间而不是组态空间中操作来克服这一挑战。然后使用反馈控制围绕这个标称轨迹调节导管,以减少不确定性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Task-Space Motion Planning of MRI-Actuated Catheters for Catheter Ablation of Atrial Fibrillation.

This paper presents a motion planning algorithm for Magnetic Resonance Imaging (MRI) actuated catheters for catheter ablation of atrial fibrillation. The MRI-actuated catheters is a new robotic catheter concept which utilizes MRI for remote steering and guidance. Magnetic moments generated by a set of coils wound near the tip are used to steer the catheter under MRI scanner magnetic field. The catheter during an ablation procedure is modeled as a constrained robotic manipulator with flexible joints, and the proposed motion-planning algorithm calculates a sequence of magnetic moments based on the manipulator model to move the tip of the catheter along a predefined trajectory on the surface of the left atrium. The difficulties in motion planning of the catheter are due to kinematic redundancy and underactuation. The proposed motion planning algorithm overcomes the challenges by operating in the task space instead of the configuration space. The catheter is then regulated around this nominal trajectory using feedback control to reduce the effect of uncertainties.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
FBG-based Shape-Sensing to Enable Lateral Deflection Methods of Autonomous Needle Insertion. An Energetic Approach to Task-Invariant Ankle Exoskeleton Control. Controlling Powered Prosthesis Kinematics over Continuous Transitions Between Walk and Stair Ascent. Effects of Personalization on Gait-State Tracking Performance Using Extended Kalman Filters. Improving Amputee Endurance over Activities of Daily Living with a Robotic Knee-Ankle Prosthesis: A Case Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1