基于sipm的正电子发射层析成像系统的CMOS前端接口ASIC。

Samrat Dey, Jacques C Rudell, Thomas K Lewellen, Robert S Miyaoka
{"title":"基于sipm的正电子发射层析成像系统的CMOS前端接口ASIC。","authors":"Samrat Dey,&nbsp;Jacques C Rudell,&nbsp;Thomas K Lewellen,&nbsp;Robert S Miyaoka","doi":"10.1109/BIOCAS.2017.8325059","DOIUrl":null,"url":null,"abstract":"<p><p>A current-mode interface chip for Silicon Photomultiplier (SiPM) array based positron emission tomography (PET) imaging front-ends is described. The circuit uses a high-speed current amplifier with a low input impedance, to minimize signal loss at the SiPM amplifier interface. To reduce the impact of dark noise, a novel high-speed threshold detection/comparator circuit is used to remove unwanted noise events. A prototype chip interfaces an array of SiPMs to the digital backend of a Positron Emission Tomography (PET) system using 64 readout channels, each of which contain a current amplifier and a threshold detection component. To reduce the number of backend channels, a row-column pulse positioning architecture (RCA) has been implemented. The ASIC occupies an area of 14.04 mm<sup>2</sup> in 130nm STMicroelectronics HCMOS9GP process. The measured input impedance of the current amplifier is 20 ohms at 10 MHz, while the threshold detection circuit's propagation delay is 0.3-2ns.</p>","PeriodicalId":73279,"journal":{"name":"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference","volume":"2017 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/BIOCAS.2017.8325059","citationCount":"5","resultStr":"{\"title\":\"A CMOS Front-End Interface ASIC for SiPM-based Positron Emission Tomography Imaging Systems.\",\"authors\":\"Samrat Dey,&nbsp;Jacques C Rudell,&nbsp;Thomas K Lewellen,&nbsp;Robert S Miyaoka\",\"doi\":\"10.1109/BIOCAS.2017.8325059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A current-mode interface chip for Silicon Photomultiplier (SiPM) array based positron emission tomography (PET) imaging front-ends is described. The circuit uses a high-speed current amplifier with a low input impedance, to minimize signal loss at the SiPM amplifier interface. To reduce the impact of dark noise, a novel high-speed threshold detection/comparator circuit is used to remove unwanted noise events. A prototype chip interfaces an array of SiPMs to the digital backend of a Positron Emission Tomography (PET) system using 64 readout channels, each of which contain a current amplifier and a threshold detection component. To reduce the number of backend channels, a row-column pulse positioning architecture (RCA) has been implemented. The ASIC occupies an area of 14.04 mm<sup>2</sup> in 130nm STMicroelectronics HCMOS9GP process. The measured input impedance of the current amplifier is 20 ohms at 10 MHz, while the threshold detection circuit's propagation delay is 0.3-2ns.</p>\",\"PeriodicalId\":73279,\"journal\":{\"name\":\"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference\",\"volume\":\"2017 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/BIOCAS.2017.8325059\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2017.8325059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/3/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2017.8325059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/3/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

介绍了一种用于硅光电倍增管(SiPM)阵列正电子发射层析成像(PET)前端的电流模式接口芯片。该电路采用低输入阻抗的高速电流放大器,最大限度地减少SiPM放大器接口的信号损耗。为了减少暗噪声的影响,采用了一种新型的高速阈值检测/比较器电路来去除不需要的噪声事件。一个原型芯片使用64个读出通道将一组SiPMs连接到正电子发射断层扫描(PET)系统的数字后端,每个通道包含一个电流放大器和一个阈值检测组件。为了减少后端信道的数量,实现了一种行列脉冲定位体系结构(RCA)。ASIC占地14.04 mm2,采用130nm意法半导体HCMOS9GP工艺。电流放大器在10 MHz时的测量输入阻抗为20欧姆,阈值检测电路的传播延迟为0.3-2ns。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A CMOS Front-End Interface ASIC for SiPM-based Positron Emission Tomography Imaging Systems.

A current-mode interface chip for Silicon Photomultiplier (SiPM) array based positron emission tomography (PET) imaging front-ends is described. The circuit uses a high-speed current amplifier with a low input impedance, to minimize signal loss at the SiPM amplifier interface. To reduce the impact of dark noise, a novel high-speed threshold detection/comparator circuit is used to remove unwanted noise events. A prototype chip interfaces an array of SiPMs to the digital backend of a Positron Emission Tomography (PET) system using 64 readout channels, each of which contain a current amplifier and a threshold detection component. To reduce the number of backend channels, a row-column pulse positioning architecture (RCA) has been implemented. The ASIC occupies an area of 14.04 mm2 in 130nm STMicroelectronics HCMOS9GP process. The measured input impedance of the current amplifier is 20 ohms at 10 MHz, while the threshold detection circuit's propagation delay is 0.3-2ns.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Microscale 3-D Capacitance Tomography with a CMOS Sensor Array. FlowMorph: Morphological Segmentation of Ultrasound-Monitored Spinal Cord Microcirculation. Programmable Electrochemical Stimulation on a Large-Scale CMOS Microelectrode Array. Design and Simulation of a Low Power 384-channel Actively Multiplexed Neural Interface. Estimating Intrinsic Manifold Dimensionality to Classify Task-Related Information in Human and Non-Human Primate Data.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1