Michael J Knight, Robin A Damion, Risto A Kauppinen
{"title":"3T时人类白质T1的角度依赖性观察。","authors":"Michael J Knight, Robin A Damion, Risto A Kauppinen","doi":"10.3233/BSI-180183","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>Multiple factors including chemical composition and microstructure influence relaxivity of tissue water <i>in vivo.</i> We have quantified T1 in the human white mater (WM) together with diffusion tensor imaging to study a possible relationship between water T1, diffusional fractional anisotropy (FA) and fibre-to-field angle.</p><p><strong>Methods: </strong>An inversion recovery (IR) pulse sequence with 6 inversion times for T1 and a multi-band diffusion tensor sequence with 60 diffusion sensitizing gradient directions for FA and the fibre-to-field angle θ (between the principal direction of diffusion and B<sub>0</sub>) were used at 3 Tesla in 40 healthy subjects. T1 was assessed using the method previously applied to anisotropy of coherence lifetime to provide a heuristic demonstration as a surface plot of T1 as a function of FA and the angle θ.</p><p><strong>Results: </strong>Our data show that in the WM voxels with FA > 0.3 T1 becomes longer (i.e. 1/T1 = R1 slower) when fibre-to-field angle is 50-60°, approximating the magic angle of 54.7°. The longer T1 around the magic angle was found in a number of WM tracts independent of anatomy. S0 signal intensity, computed from IR fits, mirrored that of T1 being greater in the WM voxels when the fibre-to-field angle was 50-60°.</p><p><strong>Conclusions: </strong>The current data point to fibre-to-field-angle dependent T1 relaxation in WM as an indication of effects of microstructure on the longitudinal relaxation of water.</p>","PeriodicalId":44239,"journal":{"name":"Biomedical Spectroscopy and Imaging","volume":"7 3-4","pages":"125-133"},"PeriodicalIF":0.3000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/BSI-180183","citationCount":"15","resultStr":"{\"title\":\"Observation of Angular Dependence of T1 in the Human White Matter at 3T.\",\"authors\":\"Michael J Knight, Robin A Damion, Risto A Kauppinen\",\"doi\":\"10.3233/BSI-180183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objective: </strong>Multiple factors including chemical composition and microstructure influence relaxivity of tissue water <i>in vivo.</i> We have quantified T1 in the human white mater (WM) together with diffusion tensor imaging to study a possible relationship between water T1, diffusional fractional anisotropy (FA) and fibre-to-field angle.</p><p><strong>Methods: </strong>An inversion recovery (IR) pulse sequence with 6 inversion times for T1 and a multi-band diffusion tensor sequence with 60 diffusion sensitizing gradient directions for FA and the fibre-to-field angle θ (between the principal direction of diffusion and B<sub>0</sub>) were used at 3 Tesla in 40 healthy subjects. T1 was assessed using the method previously applied to anisotropy of coherence lifetime to provide a heuristic demonstration as a surface plot of T1 as a function of FA and the angle θ.</p><p><strong>Results: </strong>Our data show that in the WM voxels with FA > 0.3 T1 becomes longer (i.e. 1/T1 = R1 slower) when fibre-to-field angle is 50-60°, approximating the magic angle of 54.7°. The longer T1 around the magic angle was found in a number of WM tracts independent of anatomy. S0 signal intensity, computed from IR fits, mirrored that of T1 being greater in the WM voxels when the fibre-to-field angle was 50-60°.</p><p><strong>Conclusions: </strong>The current data point to fibre-to-field-angle dependent T1 relaxation in WM as an indication of effects of microstructure on the longitudinal relaxation of water.</p>\",\"PeriodicalId\":44239,\"journal\":{\"name\":\"Biomedical Spectroscopy and Imaging\",\"volume\":\"7 3-4\",\"pages\":\"125-133\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3233/BSI-180183\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Spectroscopy and Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3233/BSI-180183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Spectroscopy and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/BSI-180183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/24 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
Observation of Angular Dependence of T1 in the Human White Matter at 3T.
Background and objective: Multiple factors including chemical composition and microstructure influence relaxivity of tissue water in vivo. We have quantified T1 in the human white mater (WM) together with diffusion tensor imaging to study a possible relationship between water T1, diffusional fractional anisotropy (FA) and fibre-to-field angle.
Methods: An inversion recovery (IR) pulse sequence with 6 inversion times for T1 and a multi-band diffusion tensor sequence with 60 diffusion sensitizing gradient directions for FA and the fibre-to-field angle θ (between the principal direction of diffusion and B0) were used at 3 Tesla in 40 healthy subjects. T1 was assessed using the method previously applied to anisotropy of coherence lifetime to provide a heuristic demonstration as a surface plot of T1 as a function of FA and the angle θ.
Results: Our data show that in the WM voxels with FA > 0.3 T1 becomes longer (i.e. 1/T1 = R1 slower) when fibre-to-field angle is 50-60°, approximating the magic angle of 54.7°. The longer T1 around the magic angle was found in a number of WM tracts independent of anatomy. S0 signal intensity, computed from IR fits, mirrored that of T1 being greater in the WM voxels when the fibre-to-field angle was 50-60°.
Conclusions: The current data point to fibre-to-field-angle dependent T1 relaxation in WM as an indication of effects of microstructure on the longitudinal relaxation of water.
期刊介绍:
Biomedical Spectroscopy and Imaging (BSI) is a multidisciplinary journal devoted to the timely publication of basic and applied research that uses spectroscopic and imaging techniques in different areas of life science including biology, biochemistry, biotechnology, bionanotechnology, environmental science, food science, pharmaceutical science, physiology and medicine. Scientists are encouraged to submit their work for publication in the form of original articles, brief communications, rapid communications, reviews and mini-reviews. Techniques covered include, but are not limited, to the following: • Vibrational Spectroscopy (Infrared, Raman, Teraherz) • Circular Dichroism Spectroscopy • Magnetic Resonance Spectroscopy (NMR, ESR) • UV-vis Spectroscopy • Mössbauer Spectroscopy • X-ray Spectroscopy (Absorption, Emission, Photoelectron, Fluorescence) • Neutron Spectroscopy • Mass Spectroscopy • Fluorescence Spectroscopy • X-ray and Neutron Scattering • Differential Scanning Calorimetry • Atomic Force Microscopy • Surface Plasmon Resonance • Magnetic Resonance Imaging • X-ray Imaging • Electron Imaging • Neutron Imaging • Raman Imaging • Infrared Imaging • Terahertz Imaging • Fluorescence Imaging • Near-infrared spectroscopy.