{"title":"ω型狭窄动脉脉动血流的非牛顿Herschel-Bulkley流体粘度模型流固耦合分析","authors":"Fahmida Ashraf, Cheol Woo Park","doi":"10.1007/s13367-022-00025-y","DOIUrl":null,"url":null,"abstract":"<p>The present study investigated the transient pulsatile blood flow of Herschel–Bulkley fluid through tapered arteries with overlapping stenosis and hyperelastic wall material by employing fully coupled fluid–structure interaction technique. 3D ω-shaped tapered arteries with hyperelastic wall material were ideally modelled with different aspect ratios (ARs), stenosis severities (SSs) and tapering angles (<span>\\(\\xi \\)</span>). The effects of non-Newtonian Herschel–Bulkley fluid model on various parameters, such as <span>\\(\\xi \\)</span>, length of stenosed region (<span>\\({\\overline{L} }_{0}\\)</span>) and SS, were explored for converging, diverging and normal arteries in terms of induced wall stresses, flow patterns and wall displacements. The differences in wall stress, flow streamlines, velocity and pressure contours were also highlighted. Wall pressure increases as SS increases; however, wall pressure suddenly decreases with the decrease in AR. The increase in SS in greater wall deformation with higher pressure gradients can be used as a remarkable indicator of hypertension. Higher average wall shear stress (AWSS) values were observed at the regions of high contact areas of stenosis to the fluid. The sudden fall in pressure can cause the stenosed vessel to collapse under the influence of low-pressure gradients. AR and <span>\\({\\overline{L} }_{0}\\)</span> can be considered important parameters to predict hypertension in overlapping stenosed arteries. The contact region of stenosed arteries should be kept under observation to reduce the further development of atherosclerosis. Higher AWSS values may help in reducing the risk of thrombosis after the stenosed region in converging tapering arteries.</p>","PeriodicalId":683,"journal":{"name":"Korea-Australia Rheology Journal","volume":"34 1","pages":"51 - 67"},"PeriodicalIF":2.2000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s13367-022-00025-y.pdf","citationCount":"2","resultStr":"{\"title\":\"Fluid–structure interaction analysis of non-Newtonian Herschel–Bulkley fluid viscosity model for pulsating flow of blood in ω-shaped stenosed arteries\",\"authors\":\"Fahmida Ashraf, Cheol Woo Park\",\"doi\":\"10.1007/s13367-022-00025-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The present study investigated the transient pulsatile blood flow of Herschel–Bulkley fluid through tapered arteries with overlapping stenosis and hyperelastic wall material by employing fully coupled fluid–structure interaction technique. 3D ω-shaped tapered arteries with hyperelastic wall material were ideally modelled with different aspect ratios (ARs), stenosis severities (SSs) and tapering angles (<span>\\\\(\\\\xi \\\\)</span>). The effects of non-Newtonian Herschel–Bulkley fluid model on various parameters, such as <span>\\\\(\\\\xi \\\\)</span>, length of stenosed region (<span>\\\\({\\\\overline{L} }_{0}\\\\)</span>) and SS, were explored for converging, diverging and normal arteries in terms of induced wall stresses, flow patterns and wall displacements. The differences in wall stress, flow streamlines, velocity and pressure contours were also highlighted. Wall pressure increases as SS increases; however, wall pressure suddenly decreases with the decrease in AR. The increase in SS in greater wall deformation with higher pressure gradients can be used as a remarkable indicator of hypertension. Higher average wall shear stress (AWSS) values were observed at the regions of high contact areas of stenosis to the fluid. The sudden fall in pressure can cause the stenosed vessel to collapse under the influence of low-pressure gradients. AR and <span>\\\\({\\\\overline{L} }_{0}\\\\)</span> can be considered important parameters to predict hypertension in overlapping stenosed arteries. The contact region of stenosed arteries should be kept under observation to reduce the further development of atherosclerosis. Higher AWSS values may help in reducing the risk of thrombosis after the stenosed region in converging tapering arteries.</p>\",\"PeriodicalId\":683,\"journal\":{\"name\":\"Korea-Australia Rheology Journal\",\"volume\":\"34 1\",\"pages\":\"51 - 67\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1007/s13367-022-00025-y.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korea-Australia Rheology Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13367-022-00025-y\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MECHANICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korea-Australia Rheology Journal","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s13367-022-00025-y","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
Fluid–structure interaction analysis of non-Newtonian Herschel–Bulkley fluid viscosity model for pulsating flow of blood in ω-shaped stenosed arteries
The present study investigated the transient pulsatile blood flow of Herschel–Bulkley fluid through tapered arteries with overlapping stenosis and hyperelastic wall material by employing fully coupled fluid–structure interaction technique. 3D ω-shaped tapered arteries with hyperelastic wall material were ideally modelled with different aspect ratios (ARs), stenosis severities (SSs) and tapering angles (\(\xi \)). The effects of non-Newtonian Herschel–Bulkley fluid model on various parameters, such as \(\xi \), length of stenosed region (\({\overline{L} }_{0}\)) and SS, were explored for converging, diverging and normal arteries in terms of induced wall stresses, flow patterns and wall displacements. The differences in wall stress, flow streamlines, velocity and pressure contours were also highlighted. Wall pressure increases as SS increases; however, wall pressure suddenly decreases with the decrease in AR. The increase in SS in greater wall deformation with higher pressure gradients can be used as a remarkable indicator of hypertension. Higher average wall shear stress (AWSS) values were observed at the regions of high contact areas of stenosis to the fluid. The sudden fall in pressure can cause the stenosed vessel to collapse under the influence of low-pressure gradients. AR and \({\overline{L} }_{0}\) can be considered important parameters to predict hypertension in overlapping stenosed arteries. The contact region of stenosed arteries should be kept under observation to reduce the further development of atherosclerosis. Higher AWSS values may help in reducing the risk of thrombosis after the stenosed region in converging tapering arteries.
期刊介绍:
The Korea-Australia Rheology Journal is devoted to fundamental and applied research with immediate or potential value in rheology, covering the science of the deformation and flow of materials. Emphases are placed on experimental and numerical advances in the areas of complex fluids. The journal offers insight into characterization and understanding of technologically important materials with a wide range of practical applications.