电缆驱动软针穿刺手术机器人的优化设计与实验

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2023-02-08 DOI:10.1115/1.4056865
Jihua Li, Qi Jiang
{"title":"电缆驱动软针穿刺手术机器人的优化设计与实验","authors":"Jihua Li, Qi Jiang","doi":"10.1115/1.4056865","DOIUrl":null,"url":null,"abstract":"\n In this paper, a cable-driven puncturing surgery robot named CPSR is proposed for soft needle. The cable-driven mechanism has lower mass, smaller dimension and smooth transmission. The motor driving the rotational joints is separated using cable which strengthen the dynamic performance of the robot. A decoupling mechanism based on movable pulley is also proposed to reduce the transmission error. Transmission error of cable-driven mechanism are also analysed to improve the control accuracy. The simulation of transmission error is completed to optimize the design parameters of cable-driven mechanism. In puncturing experiments, the feasibility of the CPSR driving the soft needle using cable-based mechanism is validated. Also the insertion error less than 0.7 mm and repeatability less than 2.5 mm are achieved. Finally the reasons limiting the accuracy and corresponding solutions are discussed. In the future research, the shape sensor will be fabricated using optic fiber and mounted on the slim needle which is helpful to complete automated operations.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimal Design and Experiment of Cable-Driven Puncturing Surgery Robot for Soft Needle\",\"authors\":\"Jihua Li, Qi Jiang\",\"doi\":\"10.1115/1.4056865\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n In this paper, a cable-driven puncturing surgery robot named CPSR is proposed for soft needle. The cable-driven mechanism has lower mass, smaller dimension and smooth transmission. The motor driving the rotational joints is separated using cable which strengthen the dynamic performance of the robot. A decoupling mechanism based on movable pulley is also proposed to reduce the transmission error. Transmission error of cable-driven mechanism are also analysed to improve the control accuracy. The simulation of transmission error is completed to optimize the design parameters of cable-driven mechanism. In puncturing experiments, the feasibility of the CPSR driving the soft needle using cable-based mechanism is validated. Also the insertion error less than 0.7 mm and repeatability less than 2.5 mm are achieved. Finally the reasons limiting the accuracy and corresponding solutions are discussed. In the future research, the shape sensor will be fabricated using optic fiber and mounted on the slim needle which is helpful to complete automated operations.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-02-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4056865\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4056865","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种缆索驱动的软针穿刺手术机器人CPSR。该机构具有质量小、尺寸小、传动平稳等优点。驱动旋转关节的电机用缆绳分开,增强了机器人的动态性能。为了减小传动误差,提出了一种基于活动皮带轮的解耦机构。为提高控制精度,分析了缆索驱动机构的传动误差。完成了传动误差仿真,优化了索驱动机构的设计参数。在穿刺实验中,验证了CPSR采用索式机构驱动软针的可行性。插入误差小于0.7 mm,重复性小于2.5 mm。最后讨论了限制精度的原因及解决方法。在未来的研究中,形状传感器将采用光纤制作,并安装在细针上,有助于完成自动化操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal Design and Experiment of Cable-Driven Puncturing Surgery Robot for Soft Needle
In this paper, a cable-driven puncturing surgery robot named CPSR is proposed for soft needle. The cable-driven mechanism has lower mass, smaller dimension and smooth transmission. The motor driving the rotational joints is separated using cable which strengthen the dynamic performance of the robot. A decoupling mechanism based on movable pulley is also proposed to reduce the transmission error. Transmission error of cable-driven mechanism are also analysed to improve the control accuracy. The simulation of transmission error is completed to optimize the design parameters of cable-driven mechanism. In puncturing experiments, the feasibility of the CPSR driving the soft needle using cable-based mechanism is validated. Also the insertion error less than 0.7 mm and repeatability less than 2.5 mm are achieved. Finally the reasons limiting the accuracy and corresponding solutions are discussed. In the future research, the shape sensor will be fabricated using optic fiber and mounted on the slim needle which is helpful to complete automated operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1