{"title":"用氯沙坦钾反相液相色谱内标法定量测定片剂剂型和血浆中盐酸伊伐布雷定的含量","authors":"Makhdoom Hs, Saeed A, Saleem F, S. K., M. M","doi":"10.26420/austinjanalpharmchem.2021.1137","DOIUrl":null,"url":null,"abstract":"A reversed-phase liquid chromatographic method for ivabradine hydrochloride using Diode Array Detector (DAD) and internal standard technique was developed and validated according to ICH and SWGTOX guidelines. The prime objective of this study was to develop a precise and accurate method that can be equally applicable to biological (plasma) as well as non-biological (active pharmaceutical ingredient and pharmaceutical tablets) matrices. Losartan potassium was used as an internal standard due to its easy availability. After liquid-liquid extraction using acetonitrile, the ivabradine hydrochloride and internal standard were chromatographed on Agilent 1200 series HPLC system equipped with DAD detector, auto-sampler and chemstation software. Analytical separation was achieved on Agilent C-18 (5µm, 25cm x 4.6mm) reversed-phase column at 30°C column oven temperature, 10μL injection volume and 286nm wavelength. Isocratic mobile phase system comprised of 60:40 v/v ratio of HPLC grade methanol and water adjusted to pH 6.8 using orthophosphoric acid was employed with 1mL/min flow rate. The method linear range was 0.025-3µg/mL (25-3000ng/mL) for pharmaceutical tablets and plasma with the coefficient of linearity ranged 0.997-0.999. Results for precision, accuracy, recovery, stability and matrix effect studies were within acceptable limits for both plasma and tablets. Method was successfully applied to the commercial tablet products and patient plasma samples to estimate the amount of ivabradine hydrochloride.","PeriodicalId":91055,"journal":{"name":"Austin journal of analytical and pharmaceutical chemistry","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reversed-Phase Liquid Chromatographic Internal Standard Method Using Losartan Potassium for Quantitative Estimation of Ivabradine Hydrochloride in Pharmaceutical Tablet Dosage Form and Plasma\",\"authors\":\"Makhdoom Hs, Saeed A, Saleem F, S. K., M. M\",\"doi\":\"10.26420/austinjanalpharmchem.2021.1137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A reversed-phase liquid chromatographic method for ivabradine hydrochloride using Diode Array Detector (DAD) and internal standard technique was developed and validated according to ICH and SWGTOX guidelines. The prime objective of this study was to develop a precise and accurate method that can be equally applicable to biological (plasma) as well as non-biological (active pharmaceutical ingredient and pharmaceutical tablets) matrices. Losartan potassium was used as an internal standard due to its easy availability. After liquid-liquid extraction using acetonitrile, the ivabradine hydrochloride and internal standard were chromatographed on Agilent 1200 series HPLC system equipped with DAD detector, auto-sampler and chemstation software. Analytical separation was achieved on Agilent C-18 (5µm, 25cm x 4.6mm) reversed-phase column at 30°C column oven temperature, 10μL injection volume and 286nm wavelength. Isocratic mobile phase system comprised of 60:40 v/v ratio of HPLC grade methanol and water adjusted to pH 6.8 using orthophosphoric acid was employed with 1mL/min flow rate. The method linear range was 0.025-3µg/mL (25-3000ng/mL) for pharmaceutical tablets and plasma with the coefficient of linearity ranged 0.997-0.999. Results for precision, accuracy, recovery, stability and matrix effect studies were within acceptable limits for both plasma and tablets. Method was successfully applied to the commercial tablet products and patient plasma samples to estimate the amount of ivabradine hydrochloride.\",\"PeriodicalId\":91055,\"journal\":{\"name\":\"Austin journal of analytical and pharmaceutical chemistry\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Austin journal of analytical and pharmaceutical chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26420/austinjanalpharmchem.2021.1137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Austin journal of analytical and pharmaceutical chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26420/austinjanalpharmchem.2021.1137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
根据ICH和SWGTOX指南,采用二极管阵列检测器(DAD)和内标技术开发并验证了盐酸伊伐布雷定的反相液相色谱法。本研究的主要目的是开发一种精确准确的方法,该方法同样适用于生物(血浆)和非生物(活性药物成分和片剂)基质。氯沙坦钾因其易得性而被用作内标。用乙腈液-液萃取后,在配备DAD检测器、自动采样器和chemstation软件的安捷伦1200系列高效液相色谱系统上对盐酸伊伐布雷定和内标物进行色谱分析。在Agilent C-18(5µm,25cm x 4.6mm)反相柱上,在30°C柱烘箱温度、10μL进样体积和286nm波长下实现分析分离。采用由60:40v/v比例的HPLC级甲醇和水组成的等色谱流动相系统,用正磷酸将pH调节至6.8,流速为1mL/min。片剂和血浆的方法线性范围为0.025-3µg/mL(25-3000ng/mL),线性系数为0.997-0.999。血浆和片剂的精密度、准确度、回收率、稳定性和基质效应研究结果均在可接受的限度内。方法成功地应用于商业片剂产品和患者血浆样品中盐酸伊伐布雷定的含量估算。
Reversed-Phase Liquid Chromatographic Internal Standard Method Using Losartan Potassium for Quantitative Estimation of Ivabradine Hydrochloride in Pharmaceutical Tablet Dosage Form and Plasma
A reversed-phase liquid chromatographic method for ivabradine hydrochloride using Diode Array Detector (DAD) and internal standard technique was developed and validated according to ICH and SWGTOX guidelines. The prime objective of this study was to develop a precise and accurate method that can be equally applicable to biological (plasma) as well as non-biological (active pharmaceutical ingredient and pharmaceutical tablets) matrices. Losartan potassium was used as an internal standard due to its easy availability. After liquid-liquid extraction using acetonitrile, the ivabradine hydrochloride and internal standard were chromatographed on Agilent 1200 series HPLC system equipped with DAD detector, auto-sampler and chemstation software. Analytical separation was achieved on Agilent C-18 (5µm, 25cm x 4.6mm) reversed-phase column at 30°C column oven temperature, 10μL injection volume and 286nm wavelength. Isocratic mobile phase system comprised of 60:40 v/v ratio of HPLC grade methanol and water adjusted to pH 6.8 using orthophosphoric acid was employed with 1mL/min flow rate. The method linear range was 0.025-3µg/mL (25-3000ng/mL) for pharmaceutical tablets and plasma with the coefficient of linearity ranged 0.997-0.999. Results for precision, accuracy, recovery, stability and matrix effect studies were within acceptable limits for both plasma and tablets. Method was successfully applied to the commercial tablet products and patient plasma samples to estimate the amount of ivabradine hydrochloride.