V. Sánchez-Monroy, Luis Enrique Barros-Martinez, Alejandro Hidalgo-Pedraza, Braulio Adriel Mendoza-Munguia, Miguel Sanchez-Brito
{"title":"利用Arduino 1利用紫外可见区表征去离子水中葡萄糖的可行性","authors":"V. Sánchez-Monroy, Luis Enrique Barros-Martinez, Alejandro Hidalgo-Pedraza, Braulio Adriel Mendoza-Munguia, Miguel Sanchez-Brito","doi":"10.17488/rmib.44.2.3","DOIUrl":null,"url":null,"abstract":"With an estimated approximately 2 million deaths per year, diabetes is one of the top 5 deadliest noncommunicable diseases globally. Although this disease is not fatal, the degradation of the patient's health due to a bad plan to control their glucose levels can have a fatal outcome. In order to lay the foundations for the development of a device that allows estimating glucose levels in some body fluid, we present the results obtained not only for the estimation of glucose in deionized water, but also describe the development and configuration of the created device. After analyzing 50 signals obtained from 5 different glucose concentrations, the feasibility of using the developed device for the analysis is evident, since, considering the K-Nearest Neighbors (KNN) algorithm, all the signals were associated correctly to the glucose group to which they belong.","PeriodicalId":38670,"journal":{"name":"Revista Mexicana de Ingenieria Biomedica","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility in the use of the UV-Visible region for the characterization of glucose in deionized water using Arduino 1\",\"authors\":\"V. Sánchez-Monroy, Luis Enrique Barros-Martinez, Alejandro Hidalgo-Pedraza, Braulio Adriel Mendoza-Munguia, Miguel Sanchez-Brito\",\"doi\":\"10.17488/rmib.44.2.3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With an estimated approximately 2 million deaths per year, diabetes is one of the top 5 deadliest noncommunicable diseases globally. Although this disease is not fatal, the degradation of the patient's health due to a bad plan to control their glucose levels can have a fatal outcome. In order to lay the foundations for the development of a device that allows estimating glucose levels in some body fluid, we present the results obtained not only for the estimation of glucose in deionized water, but also describe the development and configuration of the created device. After analyzing 50 signals obtained from 5 different glucose concentrations, the feasibility of using the developed device for the analysis is evident, since, considering the K-Nearest Neighbors (KNN) algorithm, all the signals were associated correctly to the glucose group to which they belong.\",\"PeriodicalId\":38670,\"journal\":{\"name\":\"Revista Mexicana de Ingenieria Biomedica\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Mexicana de Ingenieria Biomedica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17488/rmib.44.2.3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Mexicana de Ingenieria Biomedica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17488/rmib.44.2.3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
Feasibility in the use of the UV-Visible region for the characterization of glucose in deionized water using Arduino 1
With an estimated approximately 2 million deaths per year, diabetes is one of the top 5 deadliest noncommunicable diseases globally. Although this disease is not fatal, the degradation of the patient's health due to a bad plan to control their glucose levels can have a fatal outcome. In order to lay the foundations for the development of a device that allows estimating glucose levels in some body fluid, we present the results obtained not only for the estimation of glucose in deionized water, but also describe the development and configuration of the created device. After analyzing 50 signals obtained from 5 different glucose concentrations, the feasibility of using the developed device for the analysis is evident, since, considering the K-Nearest Neighbors (KNN) algorithm, all the signals were associated correctly to the glucose group to which they belong.
期刊介绍:
La Revista Mexicana de Ingeniería Biomédica (The Mexican Journal of Biomedical Engineering, RMIB, for its Spanish acronym) is a publication oriented to the dissemination of papers of the Mexican and international scientific community whose lines of research are aligned to the improvement of the quality of life through engineering techniques. The papers that are considered for being published in the RMIB must be original, unpublished, and first rate, and they can cover the areas of Medical Instrumentation, Biomedical Signals, Medical Information Technology, Biomaterials, Clinical Engineering, Physiological Models, and Medical Imaging as well as lines of research related to various branches of engineering applied to the health sciences.