{"title":"基于光纤传感器的肺肺活量和呼吸频率测量仪的研制","authors":"Mega Roza Lia, Harmadi Harmadi, Afdhal Muttaqin","doi":"10.25077/jif.15.1.39-47.2023","DOIUrl":null,"url":null,"abstract":"The development of measuring instruments for vital lung capacity and human respiratory rate based on the fiber-optic sensor has a system consisting of a laser diode as a light source, optical fiber as a waveguide, and OPT101 as a photodetector. This research consists of three stages: hardware design, software design, and data analysis. Each component used is tested and then tested on the entire system to determine each component's performance when used together. In the software system, the analog signal in the form of voltage from OPT101 is converted into an ADC value by an analog-to-digital converter. Based on the ADC value obtained, the threshold value is determined as the threshold for reading the respiratory rate. The number of ADC values ​​during the measurement of vital lung capacity is then converted to volume. Testing of measuring instruments is carried out by comparing the results of instruments developed with a standard medical measuring device. The results of the tests and analyses that have been carried out have obtained an accuracy value of 92.62% for the measurement of vital lung capacity, 95.14% for the measurement of respiratory rate, and 92.62% for the measurement of the respiratory rate of variations in activity.","PeriodicalId":52720,"journal":{"name":"JIF Jurnal Ilmu Fisika","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of Measuring Instruments for Lung Vital Capacity and Human Respiratory Rate Based on Fiber Optic Sensors\",\"authors\":\"Mega Roza Lia, Harmadi Harmadi, Afdhal Muttaqin\",\"doi\":\"10.25077/jif.15.1.39-47.2023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The development of measuring instruments for vital lung capacity and human respiratory rate based on the fiber-optic sensor has a system consisting of a laser diode as a light source, optical fiber as a waveguide, and OPT101 as a photodetector. This research consists of three stages: hardware design, software design, and data analysis. Each component used is tested and then tested on the entire system to determine each component's performance when used together. In the software system, the analog signal in the form of voltage from OPT101 is converted into an ADC value by an analog-to-digital converter. Based on the ADC value obtained, the threshold value is determined as the threshold for reading the respiratory rate. The number of ADC values ​​during the measurement of vital lung capacity is then converted to volume. Testing of measuring instruments is carried out by comparing the results of instruments developed with a standard medical measuring device. The results of the tests and analyses that have been carried out have obtained an accuracy value of 92.62% for the measurement of vital lung capacity, 95.14% for the measurement of respiratory rate, and 92.62% for the measurement of the respiratory rate of variations in activity.\",\"PeriodicalId\":52720,\"journal\":{\"name\":\"JIF Jurnal Ilmu Fisika\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JIF Jurnal Ilmu Fisika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25077/jif.15.1.39-47.2023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JIF Jurnal Ilmu Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/jif.15.1.39-47.2023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

以激光二极管为光源、光纤为波导、OPT101为光电探测器,研制了基于光纤传感器的肺活量和呼吸频率测量仪器。本研究分为硬件设计、软件设计和数据分析三个阶段。对使用的每个组件进行测试,然后在整个系统上进行测试,以确定每个组件一起使用时的性能。在软件系统中,通过模数转换器将来自OPT101的电压形式的模拟信号转换为ADC值。根据得到的ADC值,确定阈值作为读取呼吸速率的阈值。然后将测量肺活量期间的ADC值转换为体积。测量仪器的测试是通过与标准医疗测量装置所研制的仪器的结果进行比较来进行的。已进行的测试和分析结果表明,肺活量测量的准确率为92.62%,呼吸速率测量的准确率为95.14%,呼吸活动变化率测量的准确率为92.62%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of Measuring Instruments for Lung Vital Capacity and Human Respiratory Rate Based on Fiber Optic Sensors
The development of measuring instruments for vital lung capacity and human respiratory rate based on the fiber-optic sensor has a system consisting of a laser diode as a light source, optical fiber as a waveguide, and OPT101 as a photodetector. This research consists of three stages: hardware design, software design, and data analysis. Each component used is tested and then tested on the entire system to determine each component's performance when used together. In the software system, the analog signal in the form of voltage from OPT101 is converted into an ADC value by an analog-to-digital converter. Based on the ADC value obtained, the threshold value is determined as the threshold for reading the respiratory rate. The number of ADC values ​​during the measurement of vital lung capacity is then converted to volume. Testing of measuring instruments is carried out by comparing the results of instruments developed with a standard medical measuring device. The results of the tests and analyses that have been carried out have obtained an accuracy value of 92.62% for the measurement of vital lung capacity, 95.14% for the measurement of respiratory rate, and 92.62% for the measurement of the respiratory rate of variations in activity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
7
审稿时长
6 weeks
期刊最新文献
Development of River Flow and Water Quality Using IOT-based Smart Buoys Environment Monitoring System Particle Size Improvement and Layer Absorption of Metil Halida MAPbI3 Perovskite Doping Phenethylammonium Iodide (PEAI) Efficiency at Maximum Power of Endoreversible Quantum Otto Engine with Partial Thermalization in 3D Harmonic Potential Wind Gust Parameterization Assessment under Convective and Non-convective Events: A Case Study at the Kertajati International Airport An Analysis of the Schrodinger Equation Model for the Distribution Rate of Stock Returns
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1