使用接近高斯光束轮廓的聚甲基丙烯酸甲酯烧蚀后,激光束截断(针孔)、(有序)抖动和抖动对残余平滑度的影响

IF 2.3 Q2 OPTICS Advanced Optical Technologies Pub Date : 2021-10-14 DOI:10.1515/aot-2021-0040
Shwetabh Verma, J. Hesser, S. Arba-Mosquera
{"title":"使用接近高斯光束轮廓的聚甲基丙烯酸甲酯烧蚀后,激光束截断(针孔)、(有序)抖动和抖动对残余平滑度的影响","authors":"Shwetabh Verma, J. Hesser, S. Arba-Mosquera","doi":"10.1515/aot-2021-0040","DOIUrl":null,"url":null,"abstract":"Abstract Smoother surfaces after laser vision correction have been widely accepted as a factor for improving visual recovery regardless of the used technique (PRK, LASIK, or even SMILE). We tested the impact of laser beam truncation, dithering (expressing a continuous profile on a basis of lower resolution causing pixels to round up/down the number of pulses to be placed), and jitter (a controlled random noise (up to ±20 µm in either direction) added to the theoretical scanner positions) on residual smoothness after Poly(methyl methacrylate) (PMMA) ablations, using a close-to-Gaussian beam profile. A modified SCHWIND AMARIS system has been used providing a beam profile with the following characteristics: close-to-Gaussian beam profile with full width at half maximum (FWHM) of 540 µm, 1050 Hz. Laser parameters have been optimized following Invest. Ophthalmol. Vis. Sci., vol. 58, no. 4, pp. 2021–2037, 2017, the pulse energy has been optimized following Biomed. Opt. Express vol. 4, pp. 1422–1433, 2013. For the PMMA ablations, two configurations (with a 0.7 mm pinhole and 0.75 mJ and without pinhole and 0.9 mJ (for fluences of 329 mJ/cm2 and 317 mJ/cm2 and corneal spot volumes of 174 and 188 pl)) were considered, along with two types of lattices (with and without ordered dithering to select the optimum pulse positions), and two types of spot placement (with and without jitter). Real ablations on PMMA (ranging from −12D to +6D with and without astigmatism of up to 3D) completed the study setup. The effect of the 2 × 2 × 2 different configurations was analyzed based on the roughness in ablation estimated from the root mean square error in ablation. Truncation of the beam is negatively associated to a higher level of residual roughness; ordered dithering to select the optimum pulse positions is positively associated to a lower level of residual roughness; jitter is negatively associated to a higher level of residual roughness. The effect of dithering was the largest, followed by truncation, and jitter had the lowest impact on results. So that: Dithering approaches help to further minimize residual roughness after ablation; minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation; and jitter shall be avoided to minimize residual roughness after ablation. The proposed model can be used for optimization of laser systems used for ablation processes at relatively low cost and would directly improve the quality of results. Minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation. Ordered dithering without jitter helps to further minimize residual roughness after ablation. Other more complex dithering approaches may further contribute to minimize residual roughness after ablation.","PeriodicalId":46010,"journal":{"name":"Advanced Optical Technologies","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2021-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of laser beam truncation (pinhole), (ordered) dithering, and jitter on residual smoothness after poly(methyl methacrylate) ablations, using a close-to-Gaussian beam profile\",\"authors\":\"Shwetabh Verma, J. Hesser, S. Arba-Mosquera\",\"doi\":\"10.1515/aot-2021-0040\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Smoother surfaces after laser vision correction have been widely accepted as a factor for improving visual recovery regardless of the used technique (PRK, LASIK, or even SMILE). We tested the impact of laser beam truncation, dithering (expressing a continuous profile on a basis of lower resolution causing pixels to round up/down the number of pulses to be placed), and jitter (a controlled random noise (up to ±20 µm in either direction) added to the theoretical scanner positions) on residual smoothness after Poly(methyl methacrylate) (PMMA) ablations, using a close-to-Gaussian beam profile. A modified SCHWIND AMARIS system has been used providing a beam profile with the following characteristics: close-to-Gaussian beam profile with full width at half maximum (FWHM) of 540 µm, 1050 Hz. Laser parameters have been optimized following Invest. Ophthalmol. Vis. Sci., vol. 58, no. 4, pp. 2021–2037, 2017, the pulse energy has been optimized following Biomed. Opt. Express vol. 4, pp. 1422–1433, 2013. For the PMMA ablations, two configurations (with a 0.7 mm pinhole and 0.75 mJ and without pinhole and 0.9 mJ (for fluences of 329 mJ/cm2 and 317 mJ/cm2 and corneal spot volumes of 174 and 188 pl)) were considered, along with two types of lattices (with and without ordered dithering to select the optimum pulse positions), and two types of spot placement (with and without jitter). Real ablations on PMMA (ranging from −12D to +6D with and without astigmatism of up to 3D) completed the study setup. The effect of the 2 × 2 × 2 different configurations was analyzed based on the roughness in ablation estimated from the root mean square error in ablation. Truncation of the beam is negatively associated to a higher level of residual roughness; ordered dithering to select the optimum pulse positions is positively associated to a lower level of residual roughness; jitter is negatively associated to a higher level of residual roughness. The effect of dithering was the largest, followed by truncation, and jitter had the lowest impact on results. So that: Dithering approaches help to further minimize residual roughness after ablation; minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation; and jitter shall be avoided to minimize residual roughness after ablation. The proposed model can be used for optimization of laser systems used for ablation processes at relatively low cost and would directly improve the quality of results. Minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation. Ordered dithering without jitter helps to further minimize residual roughness after ablation. Other more complex dithering approaches may further contribute to minimize residual roughness after ablation.\",\"PeriodicalId\":46010,\"journal\":{\"name\":\"Advanced Optical Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2021-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Optical Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/aot-2021-0040\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Optical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/aot-2021-0040","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
引用次数: 1

摘要

摘要激光视力矫正后更光滑的表面已被广泛接受为改善视觉恢复的一个因素,无论使用何种技术(PRK、LASIK甚至SMILE)。我们测试了激光束截断、抖动(在较低分辨率的基础上表达连续轮廓,导致像素向上/向下舍入要放置的脉冲数量)和抖动(添加到理论扫描仪位置的受控随机噪声(在任一方向上高达±20µm))对聚甲基丙烯酸甲酯(PMMA)烧蚀后残余平滑度的影响,使用接近高斯光束轮廓。使用了一种改进的SCHWIND AMARIS系统,提供了具有以下特性的光束轮廓:接近高斯光束轮廓,半峰全宽(FWHM)为540µm,1050 Hz。激光参数已在投资后进行了优化。眼科。Vis。Sci。,第58卷,第4期,第2021–20372017页,在Biomed之后对脉冲能量进行了优化。选择《快报》第4卷,第1422-1433页,2013年。对于PMMA消融,考虑了两种配置(具有0.7mm针孔和0.75mJ,没有针孔和0.9mJ(对于329mJ/cm2和317mJ/cm2的通量以及174和188pl的角膜斑点体积)),以及两种类型的晶格(具有和不具有有序抖动以选择最佳脉冲位置)和两种类型(具有和没有抖动)的斑点放置。PMMA上的真实消融(范围从−12D到+6D,有和没有高达3D的散光)完成了研究设置。基于由消融中的均方根误差估计的消融粗糙度,分析了2×2×2不同配置的影响。光束的截断与较高水平的残余粗糙度负相关;选择最佳脉冲位置的有序抖动与较低水平的残余粗糙度正相关;抖动与较高水平的残余粗糙度负相关。抖动的影响最大,其次是截断,抖动对结果的影响最小。因此:抖动方法有助于进一步减少消融后的残余粗糙度;波束的最小(或无)截断对于最小化消融后的残余粗糙度至关重要;并且应避免抖动以最小化消融后的残余粗糙度。所提出的模型可用于以相对低的成本优化用于消融过程的激光系统,并将直接提高结果的质量。光束的最小(或无)截断对于最小化消融后的残余粗糙度至关重要。没有抖动的有序抖动有助于进一步最小化消融后的残余粗糙度。其他更复杂的抖动方法可以进一步有助于最小化消融后的残余粗糙度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of laser beam truncation (pinhole), (ordered) dithering, and jitter on residual smoothness after poly(methyl methacrylate) ablations, using a close-to-Gaussian beam profile
Abstract Smoother surfaces after laser vision correction have been widely accepted as a factor for improving visual recovery regardless of the used technique (PRK, LASIK, or even SMILE). We tested the impact of laser beam truncation, dithering (expressing a continuous profile on a basis of lower resolution causing pixels to round up/down the number of pulses to be placed), and jitter (a controlled random noise (up to ±20 µm in either direction) added to the theoretical scanner positions) on residual smoothness after Poly(methyl methacrylate) (PMMA) ablations, using a close-to-Gaussian beam profile. A modified SCHWIND AMARIS system has been used providing a beam profile with the following characteristics: close-to-Gaussian beam profile with full width at half maximum (FWHM) of 540 µm, 1050 Hz. Laser parameters have been optimized following Invest. Ophthalmol. Vis. Sci., vol. 58, no. 4, pp. 2021–2037, 2017, the pulse energy has been optimized following Biomed. Opt. Express vol. 4, pp. 1422–1433, 2013. For the PMMA ablations, two configurations (with a 0.7 mm pinhole and 0.75 mJ and without pinhole and 0.9 mJ (for fluences of 329 mJ/cm2 and 317 mJ/cm2 and corneal spot volumes of 174 and 188 pl)) were considered, along with two types of lattices (with and without ordered dithering to select the optimum pulse positions), and two types of spot placement (with and without jitter). Real ablations on PMMA (ranging from −12D to +6D with and without astigmatism of up to 3D) completed the study setup. The effect of the 2 × 2 × 2 different configurations was analyzed based on the roughness in ablation estimated from the root mean square error in ablation. Truncation of the beam is negatively associated to a higher level of residual roughness; ordered dithering to select the optimum pulse positions is positively associated to a lower level of residual roughness; jitter is negatively associated to a higher level of residual roughness. The effect of dithering was the largest, followed by truncation, and jitter had the lowest impact on results. So that: Dithering approaches help to further minimize residual roughness after ablation; minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation; and jitter shall be avoided to minimize residual roughness after ablation. The proposed model can be used for optimization of laser systems used for ablation processes at relatively low cost and would directly improve the quality of results. Minimum (or no) truncation of the beam is essential to minimize residual roughness after ablation. Ordered dithering without jitter helps to further minimize residual roughness after ablation. Other more complex dithering approaches may further contribute to minimize residual roughness after ablation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.40
自引率
0.00%
发文量
23
期刊介绍: Advanced Optical Technologies is a strictly peer-reviewed scientific journal. The major aim of Advanced Optical Technologies is to publish recent progress in the fields of optical design, optical engineering, and optical manufacturing. Advanced Optical Technologies has a main focus on applied research and addresses scientists as well as experts in industrial research and development. Advanced Optical Technologies partners with the European Optical Society (EOS). All its 4.500+ members have free online access to the journal through their EOS member account. Topics: Optical design, Lithography, Opto-mechanical engineering, Illumination and lighting technology, Precision fabrication, Image sensor devices, Optical materials (polymer based, inorganic, crystalline/amorphous), Optical instruments in life science (biology, medicine, laboratories), Optical metrology, Optics in aerospace/defense, Simulation, interdisciplinary, Optics for astronomy, Standards, Consumer optics, Optical coatings.
期刊最新文献
Technology and research on the influence of liquid crystal cladding doped with magnetic Fe3O4 nanoparticles on light propagation in an optical taper sensor Optical non-linearities and applications of ZnS phosphors Intelligent visually lossless compression of dental images Erratum: Terahertz focusing blazed diffractive optical elements for frequency demultiplexing Investigation of laser-induced contamination on dielectric thin films in MHz sub-ps regime
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1