Pieter Coenraad Swanepoel, T. Biedermann, S. J. van der Spuy
{"title":"通过减小叶尖间隙对大直径轴流冷却风扇降噪(气动增强)的实验研究","authors":"Pieter Coenraad Swanepoel, T. Biedermann, S. J. van der Spuy","doi":"10.1177/1475472X231183156","DOIUrl":null,"url":null,"abstract":"Aerodynamic and aeroacoustic performance experiments were carried out on four- and eight bladed, 1.542 m diameter, axial flow cooling fans, with constant solidity and hub-to-tip ratio. Tests were conducted in an ISO5801, Type A Fan Test facility. The tip gap (TG) was reduced from 4 mm (0.26% fan diameter) to 2 mm (0.13% fan diameter), to 0 mm, for both fan configurations. The noise profile of each fan configuration at the same TG over the whole volumetric flow rate spectrum was compared to each other. The 4 mm (0.26%) TG is used as a baseline to measure the nett increase or decrease in sound levels. Noise emissions decreased as the TG was reduced. It is discovered that the four bladed fan configuration had lower noise emissions than the eight bladed fan configuration at all blade tip clearances at design flow rate. It is concluded that reducing the TG and number of blades, at constant solidity, reduces sound emissions. The 0 mm TG for the four bladed fan produced the greatest reduction in noise emissions. An increase in fan total-to-static performance is observed when reducing the TG for both fan configurations.","PeriodicalId":49304,"journal":{"name":"International Journal of Aeroacoustics","volume":"22 1","pages":"210 - 237"},"PeriodicalIF":1.2000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Experimental noise reduction (aeroacoustical enhancement) of a large diameter axial flow cooling fan through a reduction in blade tip clearance\",\"authors\":\"Pieter Coenraad Swanepoel, T. Biedermann, S. J. van der Spuy\",\"doi\":\"10.1177/1475472X231183156\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aerodynamic and aeroacoustic performance experiments were carried out on four- and eight bladed, 1.542 m diameter, axial flow cooling fans, with constant solidity and hub-to-tip ratio. Tests were conducted in an ISO5801, Type A Fan Test facility. The tip gap (TG) was reduced from 4 mm (0.26% fan diameter) to 2 mm (0.13% fan diameter), to 0 mm, for both fan configurations. The noise profile of each fan configuration at the same TG over the whole volumetric flow rate spectrum was compared to each other. The 4 mm (0.26%) TG is used as a baseline to measure the nett increase or decrease in sound levels. Noise emissions decreased as the TG was reduced. It is discovered that the four bladed fan configuration had lower noise emissions than the eight bladed fan configuration at all blade tip clearances at design flow rate. It is concluded that reducing the TG and number of blades, at constant solidity, reduces sound emissions. The 0 mm TG for the four bladed fan produced the greatest reduction in noise emissions. An increase in fan total-to-static performance is observed when reducing the TG for both fan configurations.\",\"PeriodicalId\":49304,\"journal\":{\"name\":\"International Journal of Aeroacoustics\",\"volume\":\"22 1\",\"pages\":\"210 - 237\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Aeroacoustics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/1475472X231183156\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ACOUSTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Aeroacoustics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/1475472X231183156","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
Experimental noise reduction (aeroacoustical enhancement) of a large diameter axial flow cooling fan through a reduction in blade tip clearance
Aerodynamic and aeroacoustic performance experiments were carried out on four- and eight bladed, 1.542 m diameter, axial flow cooling fans, with constant solidity and hub-to-tip ratio. Tests were conducted in an ISO5801, Type A Fan Test facility. The tip gap (TG) was reduced from 4 mm (0.26% fan diameter) to 2 mm (0.13% fan diameter), to 0 mm, for both fan configurations. The noise profile of each fan configuration at the same TG over the whole volumetric flow rate spectrum was compared to each other. The 4 mm (0.26%) TG is used as a baseline to measure the nett increase or decrease in sound levels. Noise emissions decreased as the TG was reduced. It is discovered that the four bladed fan configuration had lower noise emissions than the eight bladed fan configuration at all blade tip clearances at design flow rate. It is concluded that reducing the TG and number of blades, at constant solidity, reduces sound emissions. The 0 mm TG for the four bladed fan produced the greatest reduction in noise emissions. An increase in fan total-to-static performance is observed when reducing the TG for both fan configurations.
期刊介绍:
International Journal of Aeroacoustics is a peer-reviewed journal publishing developments in all areas of fundamental and applied aeroacoustics. Fundamental topics include advances in understanding aeroacoustics phenomena; applied topics include all aspects of civil and military aircraft, automobile and high speed train aeroacoustics, and the impact of acoustics on structures. As well as original contributions, state of the art reviews and surveys will be published.
Subtopics include, among others, jet mixing noise; screech tones; broadband shock associated noise and methods for suppression; the near-ground acoustic environment of Short Take-Off and Vertical Landing (STOVL) aircraft; weapons bay aeroacoustics, cavity acoustics, closed-loop feedback control of aeroacoustic phenomena; computational aeroacoustics including high fidelity numerical simulations, and analytical acoustics.