{"title":"峰值偏移时间校正的自适应方法:电泳图的离散化周期","authors":"Tomas Drevinskas, A. Maruška, Gintarė Naujokaitytė, L. Telksnys, M. Kaljurand, V. Stanys, J. Cowles, Jelena Gorbatšova","doi":"10.6001/chemija.v31i3.4288","DOIUrl":null,"url":null,"abstract":"6 Département Biologique, Institut Universitaire de Technologie, University of Angers, 4 bd Lavoisier, 49016 Angers, France Capillary electrophoresis often causes unrepeatable peak migration times in the electropherogram due to changes of electroosmosis, yet in some cases this separation technique does not have a replacement alternative. Some attempts to overcome this issue have been performed introducing internal standards into the sample and compensating peak shifting in time. However, existing vector calculation-based methods are computationally intensive for portable instrumentation and usually limited to post-processing applications with 1 or 2 markers. In this work, an original approach of compensating peak migration time shift via signal discretization period correction is proposed. Using the proposed method, the number of reference points or markers that are used for compensation is extended. This method is effective in compensating migration time of peaks in real samples, where high sample injection volumes are used. Using 4 reference peaks in compensation, the method was capable of reducing the relative standard deviation of migration time of the peaks in the electropherograms more than 15 times. Corrected signal discretization periods indicated very high correlations with recorded separation currents, what can be perspective developing an adaptive peak migration time compensation method in capillary electrophoresis.","PeriodicalId":9720,"journal":{"name":"Chemija","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2020-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Towards adaptive method for peak migration time correction: discretization period in electropherograms\",\"authors\":\"Tomas Drevinskas, A. Maruška, Gintarė Naujokaitytė, L. Telksnys, M. Kaljurand, V. Stanys, J. Cowles, Jelena Gorbatšova\",\"doi\":\"10.6001/chemija.v31i3.4288\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"6 Département Biologique, Institut Universitaire de Technologie, University of Angers, 4 bd Lavoisier, 49016 Angers, France Capillary electrophoresis often causes unrepeatable peak migration times in the electropherogram due to changes of electroosmosis, yet in some cases this separation technique does not have a replacement alternative. Some attempts to overcome this issue have been performed introducing internal standards into the sample and compensating peak shifting in time. However, existing vector calculation-based methods are computationally intensive for portable instrumentation and usually limited to post-processing applications with 1 or 2 markers. In this work, an original approach of compensating peak migration time shift via signal discretization period correction is proposed. Using the proposed method, the number of reference points or markers that are used for compensation is extended. This method is effective in compensating migration time of peaks in real samples, where high sample injection volumes are used. Using 4 reference peaks in compensation, the method was capable of reducing the relative standard deviation of migration time of the peaks in the electropherograms more than 15 times. Corrected signal discretization periods indicated very high correlations with recorded separation currents, what can be perspective developing an adaptive peak migration time compensation method in capillary electrophoresis.\",\"PeriodicalId\":9720,\"journal\":{\"name\":\"Chemija\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2020-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemija\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.6001/chemija.v31i3.4288\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemija","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.6001/chemija.v31i3.4288","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Towards adaptive method for peak migration time correction: discretization period in electropherograms
6 Département Biologique, Institut Universitaire de Technologie, University of Angers, 4 bd Lavoisier, 49016 Angers, France Capillary electrophoresis often causes unrepeatable peak migration times in the electropherogram due to changes of electroosmosis, yet in some cases this separation technique does not have a replacement alternative. Some attempts to overcome this issue have been performed introducing internal standards into the sample and compensating peak shifting in time. However, existing vector calculation-based methods are computationally intensive for portable instrumentation and usually limited to post-processing applications with 1 or 2 markers. In this work, an original approach of compensating peak migration time shift via signal discretization period correction is proposed. Using the proposed method, the number of reference points or markers that are used for compensation is extended. This method is effective in compensating migration time of peaks in real samples, where high sample injection volumes are used. Using 4 reference peaks in compensation, the method was capable of reducing the relative standard deviation of migration time of the peaks in the electropherograms more than 15 times. Corrected signal discretization periods indicated very high correlations with recorded separation currents, what can be perspective developing an adaptive peak migration time compensation method in capillary electrophoresis.
期刊介绍:
Chemija publishes original research articles and reviews from all branches of modern chemistry, including physical, inorganic, analytical, organic, polymer chemistry, electrochemistry, and multidisciplinary approaches.