{"title":"利用一个新的矿柱数据库研究UG2矿柱强度","authors":"T. Oates, D. Malan","doi":"10.17159/2411-9717/2656/2023","DOIUrl":null,"url":null,"abstract":"A recent experimental pillar extraction project at a UG2 bord-and-pillar mine presented a unique opportunity to compile a new pillar database. Currently, the South African hard rock bord-and-pillar mines are designed using the Hedley and Grant formula with a modified K-value. This empirically derived formula was developed for uranium mines in the Elliot Lake district of Canada. The use of this formula for the design of pillars in South Africa is questionable. Very few pillar failures have nevertheless been observed and its current calibrations for the various reef types are possibly too conservative. A new UG2 pillar database of 66 pillars, of which seven are classified as failed, was compiled by the authors. This enabled a revised 'first-order' calibration of the K-value for the Hedley and Grant formula. The new estimated value for the UG2 is K = 75 MPa. This gives a pillar strength that is more conservative than the PlatMine formula. This work should nevertheless be considered as only a preliminary calibration as the database was small. Further work is also required to determine whether the exponents in the formula for the width and height parameters are appropriate for UG2 pillars.","PeriodicalId":17492,"journal":{"name":"Journal of The South African Institute of Mining and Metallurgy","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2023-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A study of UG2 pillar strength using a new pillar database\",\"authors\":\"T. Oates, D. Malan\",\"doi\":\"10.17159/2411-9717/2656/2023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A recent experimental pillar extraction project at a UG2 bord-and-pillar mine presented a unique opportunity to compile a new pillar database. Currently, the South African hard rock bord-and-pillar mines are designed using the Hedley and Grant formula with a modified K-value. This empirically derived formula was developed for uranium mines in the Elliot Lake district of Canada. The use of this formula for the design of pillars in South Africa is questionable. Very few pillar failures have nevertheless been observed and its current calibrations for the various reef types are possibly too conservative. A new UG2 pillar database of 66 pillars, of which seven are classified as failed, was compiled by the authors. This enabled a revised 'first-order' calibration of the K-value for the Hedley and Grant formula. The new estimated value for the UG2 is K = 75 MPa. This gives a pillar strength that is more conservative than the PlatMine formula. This work should nevertheless be considered as only a preliminary calibration as the database was small. Further work is also required to determine whether the exponents in the formula for the width and height parameters are appropriate for UG2 pillars.\",\"PeriodicalId\":17492,\"journal\":{\"name\":\"Journal of The South African Institute of Mining and Metallurgy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The South African Institute of Mining and Metallurgy\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.17159/2411-9717/2656/2023\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Materials Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The South African Institute of Mining and Metallurgy","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.17159/2411-9717/2656/2023","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Materials Science","Score":null,"Total":0}
A study of UG2 pillar strength using a new pillar database
A recent experimental pillar extraction project at a UG2 bord-and-pillar mine presented a unique opportunity to compile a new pillar database. Currently, the South African hard rock bord-and-pillar mines are designed using the Hedley and Grant formula with a modified K-value. This empirically derived formula was developed for uranium mines in the Elliot Lake district of Canada. The use of this formula for the design of pillars in South Africa is questionable. Very few pillar failures have nevertheless been observed and its current calibrations for the various reef types are possibly too conservative. A new UG2 pillar database of 66 pillars, of which seven are classified as failed, was compiled by the authors. This enabled a revised 'first-order' calibration of the K-value for the Hedley and Grant formula. The new estimated value for the UG2 is K = 75 MPa. This gives a pillar strength that is more conservative than the PlatMine formula. This work should nevertheless be considered as only a preliminary calibration as the database was small. Further work is also required to determine whether the exponents in the formula for the width and height parameters are appropriate for UG2 pillars.
期刊介绍:
The Journal serves as a medium for the publication of high quality scientific papers. This requires that the papers that are submitted for publication are properly and fairly refereed and edited. This process will maintain the high quality of the presentation of the paper and ensure that the technical content is in line with the accepted norms of scientific integrity.