C. E. Rodríguez, O. Kolokoltsev, D. Matatagui, N. Qureshi, C. Ordóñez
{"title":"利用有源微波共振探针表征纳米级液滴。","authors":"C. E. Rodríguez, O. Kolokoltsev, D. Matatagui, N. Qureshi, C. Ordóñez","doi":"10.22201/icat.24486736e.2023.21.2.1992","DOIUrl":null,"url":null,"abstract":"In this work we present a microwave intracavity sensor for the characterization of aqueous solutions of nano-liter sessile droplets, deposited on the microstrip line electrode. The sensor operates at frequency and is based on tunable magnonic delay line oscillator. The samples were characterized by using their evaporation dynamics, by measuring their dielectric constants. The experiments have shown that the sensor is capable of detecting the salinity (S) of water with the required precision and resolution. The advantage of the sensor is the possibility of measuring the parameters such as S, Total Dissolved and Total Suspended Solids, simultaneously.","PeriodicalId":15073,"journal":{"name":"Journal of Applied Research and Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Characterization of Nano-liter Sessile Droplets By Using An Active Microwave Resonance Probe.\",\"authors\":\"C. E. Rodríguez, O. Kolokoltsev, D. Matatagui, N. Qureshi, C. Ordóñez\",\"doi\":\"10.22201/icat.24486736e.2023.21.2.1992\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work we present a microwave intracavity sensor for the characterization of aqueous solutions of nano-liter sessile droplets, deposited on the microstrip line electrode. The sensor operates at frequency and is based on tunable magnonic delay line oscillator. The samples were characterized by using their evaporation dynamics, by measuring their dielectric constants. The experiments have shown that the sensor is capable of detecting the salinity (S) of water with the required precision and resolution. The advantage of the sensor is the possibility of measuring the parameters such as S, Total Dissolved and Total Suspended Solids, simultaneously.\",\"PeriodicalId\":15073,\"journal\":{\"name\":\"Journal of Applied Research and Technology\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Research and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22201/icat.24486736e.2023.21.2.1992\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Research and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22201/icat.24486736e.2023.21.2.1992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Characterization of Nano-liter Sessile Droplets By Using An Active Microwave Resonance Probe.
In this work we present a microwave intracavity sensor for the characterization of aqueous solutions of nano-liter sessile droplets, deposited on the microstrip line electrode. The sensor operates at frequency and is based on tunable magnonic delay line oscillator. The samples were characterized by using their evaporation dynamics, by measuring their dielectric constants. The experiments have shown that the sensor is capable of detecting the salinity (S) of water with the required precision and resolution. The advantage of the sensor is the possibility of measuring the parameters such as S, Total Dissolved and Total Suspended Solids, simultaneously.
期刊介绍:
The Journal of Applied Research and Technology (JART) is a bimonthly open access journal that publishes papers on innovative applications, development of new technologies and efficient solutions in engineering, computing and scientific research. JART publishes manuscripts describing original research, with significant results based on experimental, theoretical and numerical work.
The journal does not charge for submission, processing, publication of manuscripts or for color reproduction of photographs.
JART classifies research into the following main fields:
-Material Science:
Biomaterials, carbon, ceramics, composite, metals, polymers, thin films, functional materials and semiconductors.
-Computer Science:
Computer graphics and visualization, programming, human-computer interaction, neural networks, image processing and software engineering.
-Industrial Engineering:
Operations research, systems engineering, management science, complex systems and cybernetics applications and information technologies
-Electronic Engineering:
Solid-state physics, radio engineering, telecommunications, control systems, signal processing, power electronics, electronic devices and circuits and automation.
-Instrumentation engineering and science:
Measurement devices (pressure, temperature, flow, voltage, frequency etc.), precision engineering, medical devices, instrumentation for education (devices and software), sensor technology, mechatronics and robotics.