{"title":"测量液体复介电常数的同轴谐振腔","authors":"Yi Wang, Zhixia Xu, Yulin Feng, Shaojun Fang","doi":"10.1515/freq-2022-0115","DOIUrl":null,"url":null,"abstract":"Abstract In this letter, a new microwave sensor of the coaxial resonant cavity with a single-open-ended circuit loaded capacitor is proposed and used to detect the liquids’ complex permittivity. The improved cavity has a higher internal electric field and smaller size when compared with the cylindrical cavity, which gives the sensor a high sensitivity in measuring liquids’ complex permittivity. A coaxial resonant cavity operating in 1.9 GHz was designed in this work. The silicone hose used for the test is inserted vertically from the center of the cavity, and the liquids under test (LUTs) are guaranteed to be 2 ml each time. The dielectric properties of LUTs will cause perturbation to the internal electric field of the cavity. By analyzing the measured data, the sensitivity of the cavity is 0.12%, and the relative errors of the real part of the measured value and the reference value are 3.67%. which shows the measured value has a good agreement with the reference value.","PeriodicalId":55143,"journal":{"name":"Frequenz","volume":"77 1","pages":"229 - 234"},"PeriodicalIF":0.8000,"publicationDate":"2022-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Coaxial resonant cavity for measuring complex permittivity of liquids\",\"authors\":\"Yi Wang, Zhixia Xu, Yulin Feng, Shaojun Fang\",\"doi\":\"10.1515/freq-2022-0115\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In this letter, a new microwave sensor of the coaxial resonant cavity with a single-open-ended circuit loaded capacitor is proposed and used to detect the liquids’ complex permittivity. The improved cavity has a higher internal electric field and smaller size when compared with the cylindrical cavity, which gives the sensor a high sensitivity in measuring liquids’ complex permittivity. A coaxial resonant cavity operating in 1.9 GHz was designed in this work. The silicone hose used for the test is inserted vertically from the center of the cavity, and the liquids under test (LUTs) are guaranteed to be 2 ml each time. The dielectric properties of LUTs will cause perturbation to the internal electric field of the cavity. By analyzing the measured data, the sensitivity of the cavity is 0.12%, and the relative errors of the real part of the measured value and the reference value are 3.67%. which shows the measured value has a good agreement with the reference value.\",\"PeriodicalId\":55143,\"journal\":{\"name\":\"Frequenz\",\"volume\":\"77 1\",\"pages\":\"229 - 234\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frequenz\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/freq-2022-0115\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frequenz","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/freq-2022-0115","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Coaxial resonant cavity for measuring complex permittivity of liquids
Abstract In this letter, a new microwave sensor of the coaxial resonant cavity with a single-open-ended circuit loaded capacitor is proposed and used to detect the liquids’ complex permittivity. The improved cavity has a higher internal electric field and smaller size when compared with the cylindrical cavity, which gives the sensor a high sensitivity in measuring liquids’ complex permittivity. A coaxial resonant cavity operating in 1.9 GHz was designed in this work. The silicone hose used for the test is inserted vertically from the center of the cavity, and the liquids under test (LUTs) are guaranteed to be 2 ml each time. The dielectric properties of LUTs will cause perturbation to the internal electric field of the cavity. By analyzing the measured data, the sensitivity of the cavity is 0.12%, and the relative errors of the real part of the measured value and the reference value are 3.67%. which shows the measured value has a good agreement with the reference value.
期刊介绍:
Frequenz is one of the leading scientific and technological journals covering all aspects of RF-, Microwave-, and THz-Engineering. It is a peer-reviewed, bi-monthly published journal.
Frequenz was first published in 1947 with a circulation of 7000 copies, focusing on telecommunications. Today, the major objective of Frequenz is to highlight current research activities and development efforts in RF-, Microwave-, and THz-Engineering throughout a wide frequency spectrum ranging from radio via microwave up to THz frequencies.
RF-, Microwave-, and THz-Engineering is a very active area of Research & Development as well as of Applications in a wide variety of fields. It has been the key to enabling technologies responsible for phenomenal growth of satellite broadcasting, wireless communications, satellite and terrestrial mobile communications and navigation, high-speed THz communication systems. It will open up new technologies in communications, radar, remote sensing and imaging, in identification and localization as well as in sensors, e.g. for wireless industrial process and environmental monitoring as well as for biomedical sensing.