工业环境抓取辅助装置的设计与初步验证

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2021-11-03 DOI:10.1115/1.4052899
Daniel Loewen, N. Chandrashekar
{"title":"工业环境抓取辅助装置的设计与初步验证","authors":"Daniel Loewen, N. Chandrashekar","doi":"10.1115/1.4052899","DOIUrl":null,"url":null,"abstract":"\n Carpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active orthosis system. A novel soft, pneumatic grasp assist device, that used a unique design of sinusoidal bellows oriented at 45 degrees, was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assist device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. Results showed that the grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p<0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assist device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p<0.05). The study showed that using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Preliminary Validation of Grasp Assistive Device for an Industrial Environment\",\"authors\":\"Daniel Loewen, N. Chandrashekar\",\"doi\":\"10.1115/1.4052899\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Carpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active orthosis system. A novel soft, pneumatic grasp assist device, that used a unique design of sinusoidal bellows oriented at 45 degrees, was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assist device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. Results showed that the grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p<0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assist device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p<0.05). The study showed that using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4052899\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4052899","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

腕管综合征和肌腱炎是两种常见的上肢累积性创伤障碍(CTD),与工业环境中的重复和剧烈活动有关。在操作手枪握把手持工具等活动中减少肌肉力量可以降低CTDs的发生率。本研究的目的是使用主动矫形器系统来减少肌肉对握力的贡献。设计了一种新型的柔软气动抓握辅助装置,该装置采用了45度正弦波纹管的独特设计,以增强使用者在手枪式抓握手持工具操作过程中的力量。使用快速原型制作了优化设计。在一项常见工业活动的体内研究中,通过测量肌肉活动和握力来量化器械的有效性。一家汽车制造商使用电动工具的九名受试者使用手枪式握把直流工具安装了18个紧固件,无论是否使用握把辅助装置。表面肌电图(sEMG)用于测量四块通常与抓握相关的肌肉的活动。结果显示,抓握辅助显著降低了18%的平均、综合、标准化肌肉活动(p<0.05)。使用修订的应变指数(RSI)对肌肉激活结果进行了分析。抓握辅助装置试验的平均RSI值比典型试验低13%(p<0.05)。研究表明,使用主动抓握辅助矫形器可以降低使用直流手动工具的身体健全的工业工人的CTD发生率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Preliminary Validation of Grasp Assistive Device for an Industrial Environment
Carpal tunnel syndrome and tendonitis are two common upper extremity cumulative trauma disorders (CTD) related to repetitive and forceful activities in industrial environments. Reducing the muscular force during activities such as the operation of a pistol grip hand tool could result in lower incidence of CTDs. The objective of this research was to reduce the muscular contribution to the grip force using an active orthosis system. A novel soft, pneumatic grasp assist device, that used a unique design of sinusoidal bellows oriented at 45 degrees, was designed to augment the users' strength during operation of pistol grip hand tool. The optimized design was fabricated using rapid prototyping. Device effectiveness was quantified by measuring muscle activity and grip force during an in vivo study of a common industrial activity. Nine subjects experienced with power tools employed by an automobile manufacturer installed 18 fasteners using a pistol grip DC tool with and without the grasp assist device. Surface electromyography (sEMG) was used to measure the activity of four muscles commonly associated with grasping. Results showed that the grasp assist significantly reduced the mean, combined, normalized muscle activity by 18% (p<0.05). Muscle activation results were contextualized using the revised strain index (RSI). The grasp assist device trial yielded a significantly lower mean RSI value than the typical trial by 13% (p<0.05). The study showed that using an active grasp assist orthosis could reduce the incidence of CTDs in able bodied industrial workers using DC hand tools.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1