E. Malaekah, Khaled Al Awam, Husham Farouk, Elamir Abuabid, V. Mukhanov, A. Alahmari, Hasan Alshagag
{"title":"基于Arduino和树莓派4的混合机械呼吸系统设计","authors":"E. Malaekah, Khaled Al Awam, Husham Farouk, Elamir Abuabid, V. Mukhanov, A. Alahmari, Hasan Alshagag","doi":"10.1115/1.4054036","DOIUrl":null,"url":null,"abstract":"\n Mechanical ventilators are advanced life-supporting machines in the present century. The ventilator needs to be safe, flexible, and easy for competent clinicians to use. Since ventilators supply the patient with gas, they need pneumatic components to be present. First technology ventilators were typically powered by pneumatic energy. Gas pressure is used to power ventilators as well as ventilate patients. Nowadays, ventilators are operated electronically with the useful microprocessor tool. This proposal aims to design a simple portable mechanical ventilator that includes measuring some important physiological variables such as respiratory rate, heart rate, and O2 saturation, which can be utilized in hospital and at home. The proposed system includes Arduino, Rasspary pi4, touch screen and graphical user interface. This study showed a significant individual performance for measuring some important parameters such as flow rate, tidal volume, and minute ventilation. The accuracy of measuring the flow rate was 72%. The Cohen's Kappa (CK) was estimated to be 0.61. The accuracy of calculated the tidal volume was estimated at 83% with 0.80 CK. The accuracy of measuring the O2 saturation was estimated at 99% with 0.99 CK. The advantages of the proposed design are cost-effective, safe, flexible, and easy to use. Also, this system is smart and can control its transactions, so it can be used at home without the need for professional help. The operating parameters can also be set by the user with a simple user interface.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Designing Hybrid Mechanical Ventilator System Based On Arduino and Raspberry Pi 4\",\"authors\":\"E. Malaekah, Khaled Al Awam, Husham Farouk, Elamir Abuabid, V. Mukhanov, A. Alahmari, Hasan Alshagag\",\"doi\":\"10.1115/1.4054036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Mechanical ventilators are advanced life-supporting machines in the present century. The ventilator needs to be safe, flexible, and easy for competent clinicians to use. Since ventilators supply the patient with gas, they need pneumatic components to be present. First technology ventilators were typically powered by pneumatic energy. Gas pressure is used to power ventilators as well as ventilate patients. Nowadays, ventilators are operated electronically with the useful microprocessor tool. This proposal aims to design a simple portable mechanical ventilator that includes measuring some important physiological variables such as respiratory rate, heart rate, and O2 saturation, which can be utilized in hospital and at home. The proposed system includes Arduino, Rasspary pi4, touch screen and graphical user interface. This study showed a significant individual performance for measuring some important parameters such as flow rate, tidal volume, and minute ventilation. The accuracy of measuring the flow rate was 72%. The Cohen's Kappa (CK) was estimated to be 0.61. The accuracy of calculated the tidal volume was estimated at 83% with 0.80 CK. The accuracy of measuring the O2 saturation was estimated at 99% with 0.99 CK. The advantages of the proposed design are cost-effective, safe, flexible, and easy to use. Also, this system is smart and can control its transactions, so it can be used at home without the need for professional help. The operating parameters can also be set by the user with a simple user interface.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4054036\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4054036","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Designing Hybrid Mechanical Ventilator System Based On Arduino and Raspberry Pi 4
Mechanical ventilators are advanced life-supporting machines in the present century. The ventilator needs to be safe, flexible, and easy for competent clinicians to use. Since ventilators supply the patient with gas, they need pneumatic components to be present. First technology ventilators were typically powered by pneumatic energy. Gas pressure is used to power ventilators as well as ventilate patients. Nowadays, ventilators are operated electronically with the useful microprocessor tool. This proposal aims to design a simple portable mechanical ventilator that includes measuring some important physiological variables such as respiratory rate, heart rate, and O2 saturation, which can be utilized in hospital and at home. The proposed system includes Arduino, Rasspary pi4, touch screen and graphical user interface. This study showed a significant individual performance for measuring some important parameters such as flow rate, tidal volume, and minute ventilation. The accuracy of measuring the flow rate was 72%. The Cohen's Kappa (CK) was estimated to be 0.61. The accuracy of calculated the tidal volume was estimated at 83% with 0.80 CK. The accuracy of measuring the O2 saturation was estimated at 99% with 0.99 CK. The advantages of the proposed design are cost-effective, safe, flexible, and easy to use. Also, this system is smart and can control its transactions, so it can be used at home without the need for professional help. The operating parameters can also be set by the user with a simple user interface.
期刊介绍:
The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.