{"title":"一种新的子宫颈本体感觉测量方法的有效性和可靠性","authors":"A. Köseoğlu, D. Coskunsu, E. Mutlu","doi":"10.1055/a-1761-5962","DOIUrl":null,"url":null,"abstract":"\n Objective An accurate and reliable measurement of proprioception is\n important in the evaluation of the cervical. The aim of this study is to\n investigate the validity and reliability of a new method using Horizontal Plane\n Target Platform (HPTP) to assess Head Repositioning Accuracy (HRA) for Cervical\n Proprioception (CP).\n Methods HRA values of 86 healthy volunteers\n (21.01±2.16 yrs.) were measured through AOS PropPoint laser\n apparatus device on HPTP, Frontal Plane Target Platform (FPTP), and also CROM\n device to assess test-retest reliability and validity.\n Results The test-retest measurements of HPTP reliability was\n (ICCleft=0.69, ICCright=0.74;\n SEMleft=0.28, SEMright=0.36;\n MDCleft=1.85, MDCright=2.02\n 95%CI) were moderate for both side. Correlation with the CROM device\n results was moderate for both side (r=0.75 for left size, r=0.83\n for right side), and the absolute values demonstrate concordance between results\n using the Bland-Altman method.\n Conclusions HRA measurements performed with a laser apparatus on HPTP\n which we developed can be used as an alternative method in CP evaluation.","PeriodicalId":54611,"journal":{"name":"Physikalische Medizin Rehabilitationsmedizin Kurortmedizin","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Validity and Reliability of a New Method to Measure Cervical\\n Proprioception\",\"authors\":\"A. Köseoğlu, D. Coskunsu, E. Mutlu\",\"doi\":\"10.1055/a-1761-5962\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Objective An accurate and reliable measurement of proprioception is\\n important in the evaluation of the cervical. The aim of this study is to\\n investigate the validity and reliability of a new method using Horizontal Plane\\n Target Platform (HPTP) to assess Head Repositioning Accuracy (HRA) for Cervical\\n Proprioception (CP).\\n Methods HRA values of 86 healthy volunteers\\n (21.01±2.16 yrs.) were measured through AOS PropPoint laser\\n apparatus device on HPTP, Frontal Plane Target Platform (FPTP), and also CROM\\n device to assess test-retest reliability and validity.\\n Results The test-retest measurements of HPTP reliability was\\n (ICCleft=0.69, ICCright=0.74;\\n SEMleft=0.28, SEMright=0.36;\\n MDCleft=1.85, MDCright=2.02\\n 95%CI) were moderate for both side. Correlation with the CROM device\\n results was moderate for both side (r=0.75 for left size, r=0.83\\n for right side), and the absolute values demonstrate concordance between results\\n using the Bland-Altman method.\\n Conclusions HRA measurements performed with a laser apparatus on HPTP\\n which we developed can be used as an alternative method in CP evaluation.\",\"PeriodicalId\":54611,\"journal\":{\"name\":\"Physikalische Medizin Rehabilitationsmedizin Kurortmedizin\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physikalische Medizin Rehabilitationsmedizin Kurortmedizin\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-1761-5962\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physikalische Medizin Rehabilitationsmedizin Kurortmedizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1761-5962","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REHABILITATION","Score":null,"Total":0}
Validity and Reliability of a New Method to Measure Cervical
Proprioception
Objective An accurate and reliable measurement of proprioception is
important in the evaluation of the cervical. The aim of this study is to
investigate the validity and reliability of a new method using Horizontal Plane
Target Platform (HPTP) to assess Head Repositioning Accuracy (HRA) for Cervical
Proprioception (CP).
Methods HRA values of 86 healthy volunteers
(21.01±2.16 yrs.) were measured through AOS PropPoint laser
apparatus device on HPTP, Frontal Plane Target Platform (FPTP), and also CROM
device to assess test-retest reliability and validity.
Results The test-retest measurements of HPTP reliability was
(ICCleft=0.69, ICCright=0.74;
SEMleft=0.28, SEMright=0.36;
MDCleft=1.85, MDCright=2.02
95%CI) were moderate for both side. Correlation with the CROM device
results was moderate for both side (r=0.75 for left size, r=0.83
for right side), and the absolute values demonstrate concordance between results
using the Bland-Altman method.
Conclusions HRA measurements performed with a laser apparatus on HPTP
which we developed can be used as an alternative method in CP evaluation.
期刊介绍:
The Journal of Physical and Rehabilitation Medicine offers you the most up-to-date information about physical medicine in clinic and practice, as well as interdisciplinary information about rehabilitation medicine and spa medicine.
Publishing 6 issues a year, the journal includes selected original research articles and reviews as well as guidelines and summaries of the latest research findings. The journal also publishes society news and editorial material. “Online first” publication ensures rapid dissemination of knowledge.