Biagio Castaldi , Gianfranco Butera , Massimo Chessa , Lorenzo Galletti , Alessandro Giamberti , Luca Giugno , Aurelio Secinaro , Vladimiro Vida , Giovanni Di Salvo , Mario Carminati
{"title":"经导管肺动脉瓣植入在临床实践中的应用:全国心脏植入和非植入医师的调查","authors":"Biagio Castaldi , Gianfranco Butera , Massimo Chessa , Lorenzo Galletti , Alessandro Giamberti , Luca Giugno , Aurelio Secinaro , Vladimiro Vida , Giovanni Di Salvo , Mario Carminati","doi":"10.1016/j.ijcchd.2023.100478","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><p>Transcatheter Pulmonary Valve Implantation (TPVI), when feasible, is the first-line approach to pulmonary valve replacement. Our aim was to obtain a picture of current TPVI practice in Italy.</p></div><div><h3>Methods</h3><p>After conducting a literature review on TPVI, online surveys were devised by an Advisory Board of 10 experts from the three Italian reference centers for congenital heart diseases and sent electronically to physicians working either in implanting center or in referral non-implanting cardiologic centers.</p></div><div><h3>Results</h3><p>Approximately 450 physicians across Italy were invited to contribute. 82 (18%) physicians answered. EchoColorDoppler, electrocardiogram and cardiac magnetic resonance were considered the first line approach to monitor these patients, before and after TPVI.</p><p>For non-implanting centers, reasons for non-referral of patients for PVR were: paucisymptomatic disease (67%) and patients’ poor adherence to disease management programs (41%), but also the lack of connections with specialized centers (33%). For implanters, the main reasons for refraining from TPVI were: high risk for coronary compression (67% first rank), the need for concomitant cardiac surgical procedures (39% first rank) and the unsuitable anatomy of the conduit (39% first rank). The availability of new larger valves of a self-expandable nature was indicated as a key technological development for expanding the cohort of patients currently eligible for TPVI.</p></div><div><h3>Conclusions</h3><p>Despite a non-invasive imaging protocol for the follow up and selection of patients candidate to TPVI is well implemented in Italy, there is still a lack in connections between non-implanting and implanting centers.</p></div>","PeriodicalId":73429,"journal":{"name":"International journal of cardiology. Congenital heart disease","volume":"14 ","pages":"Article 100478"},"PeriodicalIF":0.8000,"publicationDate":"2023-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transcatheter pulmonary valve implantation in clinical practice: A nationwide survey of cardiological implanting and non-implanting physicians\",\"authors\":\"Biagio Castaldi , Gianfranco Butera , Massimo Chessa , Lorenzo Galletti , Alessandro Giamberti , Luca Giugno , Aurelio Secinaro , Vladimiro Vida , Giovanni Di Salvo , Mario Carminati\",\"doi\":\"10.1016/j.ijcchd.2023.100478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aim</h3><p>Transcatheter Pulmonary Valve Implantation (TPVI), when feasible, is the first-line approach to pulmonary valve replacement. Our aim was to obtain a picture of current TPVI practice in Italy.</p></div><div><h3>Methods</h3><p>After conducting a literature review on TPVI, online surveys were devised by an Advisory Board of 10 experts from the three Italian reference centers for congenital heart diseases and sent electronically to physicians working either in implanting center or in referral non-implanting cardiologic centers.</p></div><div><h3>Results</h3><p>Approximately 450 physicians across Italy were invited to contribute. 82 (18%) physicians answered. EchoColorDoppler, electrocardiogram and cardiac magnetic resonance were considered the first line approach to monitor these patients, before and after TPVI.</p><p>For non-implanting centers, reasons for non-referral of patients for PVR were: paucisymptomatic disease (67%) and patients’ poor adherence to disease management programs (41%), but also the lack of connections with specialized centers (33%). For implanters, the main reasons for refraining from TPVI were: high risk for coronary compression (67% first rank), the need for concomitant cardiac surgical procedures (39% first rank) and the unsuitable anatomy of the conduit (39% first rank). The availability of new larger valves of a self-expandable nature was indicated as a key technological development for expanding the cohort of patients currently eligible for TPVI.</p></div><div><h3>Conclusions</h3><p>Despite a non-invasive imaging protocol for the follow up and selection of patients candidate to TPVI is well implemented in Italy, there is still a lack in connections between non-implanting and implanting centers.</p></div>\",\"PeriodicalId\":73429,\"journal\":{\"name\":\"International journal of cardiology. Congenital heart disease\",\"volume\":\"14 \",\"pages\":\"Article 100478\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of cardiology. Congenital heart disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S266666852300040X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of cardiology. Congenital heart disease","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266666852300040X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Transcatheter pulmonary valve implantation in clinical practice: A nationwide survey of cardiological implanting and non-implanting physicians
Aim
Transcatheter Pulmonary Valve Implantation (TPVI), when feasible, is the first-line approach to pulmonary valve replacement. Our aim was to obtain a picture of current TPVI practice in Italy.
Methods
After conducting a literature review on TPVI, online surveys were devised by an Advisory Board of 10 experts from the three Italian reference centers for congenital heart diseases and sent electronically to physicians working either in implanting center or in referral non-implanting cardiologic centers.
Results
Approximately 450 physicians across Italy were invited to contribute. 82 (18%) physicians answered. EchoColorDoppler, electrocardiogram and cardiac magnetic resonance were considered the first line approach to monitor these patients, before and after TPVI.
For non-implanting centers, reasons for non-referral of patients for PVR were: paucisymptomatic disease (67%) and patients’ poor adherence to disease management programs (41%), but also the lack of connections with specialized centers (33%). For implanters, the main reasons for refraining from TPVI were: high risk for coronary compression (67% first rank), the need for concomitant cardiac surgical procedures (39% first rank) and the unsuitable anatomy of the conduit (39% first rank). The availability of new larger valves of a self-expandable nature was indicated as a key technological development for expanding the cohort of patients currently eligible for TPVI.
Conclusions
Despite a non-invasive imaging protocol for the follow up and selection of patients candidate to TPVI is well implemented in Italy, there is still a lack in connections between non-implanting and implanting centers.