{"title":"薄触点电阻$({\\leq}{\\rm 0.5}~\\mu{\\rm m})$镀金触点:镀金厚度的影响","authors":"P. Misra, J. Nagaraju","doi":"10.1109/TCAPT.2010.2060340","DOIUrl":null,"url":null,"abstract":"This paper describes the electrical contact resistance (ECR) measurements made on thin gold plated (gold plating of ≤ 0.5 μm with a Ni underlayer of ~2 μm) oxygen free high conductivity (OFHC) Cu contacts in vacuum environment. ECR in gold plated OFHC Cu contacts is found to be slightly higher than that in bare OFHC Cu contacts. Even though gold is a softer material than copper, the relatively high ECR values observed in gold plated contacts are mainly due to the higher hardness and electrical resistivity of the underlying Ni layer. It is well known that ECR is directly related to plating factor, which increases with increasing coating thickness when the electrical resistivity of coating material is more than that of substrate. Surprisingly, in the present case it is found that the ECR decreases with increasing gold layer thickness on OFHC Cu substrate (gold has higher electrical resistivity than OFHC Cu). It is analytically demonstrated from the topography and microhardness measurements results that this peculiar behavior is associated with thin gold platings, where the changes in surface roughness and microhardness with increasing layer thickness overshadow the effect of plating factor on ECR.","PeriodicalId":55013,"journal":{"name":"IEEE Transactions on Components and Packaging Technologies","volume":"41 1","pages":"830-835"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TCAPT.2010.2060340","citationCount":"15","resultStr":"{\"title\":\"Electrical Contact Resistance in Thin $({\\\\leq}{\\\\rm 0.5}~\\\\mu{\\\\rm m})$ Gold Plated Contacts: Effect of Gold Plating Thickness\",\"authors\":\"P. Misra, J. Nagaraju\",\"doi\":\"10.1109/TCAPT.2010.2060340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the electrical contact resistance (ECR) measurements made on thin gold plated (gold plating of ≤ 0.5 μm with a Ni underlayer of ~2 μm) oxygen free high conductivity (OFHC) Cu contacts in vacuum environment. ECR in gold plated OFHC Cu contacts is found to be slightly higher than that in bare OFHC Cu contacts. Even though gold is a softer material than copper, the relatively high ECR values observed in gold plated contacts are mainly due to the higher hardness and electrical resistivity of the underlying Ni layer. It is well known that ECR is directly related to plating factor, which increases with increasing coating thickness when the electrical resistivity of coating material is more than that of substrate. Surprisingly, in the present case it is found that the ECR decreases with increasing gold layer thickness on OFHC Cu substrate (gold has higher electrical resistivity than OFHC Cu). It is analytically demonstrated from the topography and microhardness measurements results that this peculiar behavior is associated with thin gold platings, where the changes in surface roughness and microhardness with increasing layer thickness overshadow the effect of plating factor on ECR.\",\"PeriodicalId\":55013,\"journal\":{\"name\":\"IEEE Transactions on Components and Packaging Technologies\",\"volume\":\"41 1\",\"pages\":\"830-835\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/TCAPT.2010.2060340\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Components and Packaging Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TCAPT.2010.2060340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Components and Packaging Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TCAPT.2010.2060340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文介绍了真空环境下无氧高导电性铜(OFHC)薄镀金(镀金≤0.5 μm,下镀Ni ~2 μm)触点的接触电阻(ECR)测量。发现镀金的OFHC铜触点的ECR略高于裸的OFHC铜触点。尽管金是一种比铜更软的材料,但在镀金触点中观察到的相对较高的ECR值主要是由于下面的Ni层的硬度和电阻率更高。众所周知,ECR与镀层因子直接相关,当镀层材料的电阻率大于衬底的电阻率时,ECR随镀层厚度的增加而增大。令人惊讶的是,在这种情况下,发现ECR随着OFHC Cu衬底上金层厚度的增加而降低(金的电阻率比OFHC Cu高)。从形貌和显微硬度测量结果分析表明,这种特殊行为与薄镀金层有关,其中表面粗糙度和显微硬度随层厚度的变化掩盖了镀因子对ECR的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Electrical Contact Resistance in Thin $({\leq}{\rm 0.5}~\mu{\rm m})$ Gold Plated Contacts: Effect of Gold Plating Thickness
This paper describes the electrical contact resistance (ECR) measurements made on thin gold plated (gold plating of ≤ 0.5 μm with a Ni underlayer of ~2 μm) oxygen free high conductivity (OFHC) Cu contacts in vacuum environment. ECR in gold plated OFHC Cu contacts is found to be slightly higher than that in bare OFHC Cu contacts. Even though gold is a softer material than copper, the relatively high ECR values observed in gold plated contacts are mainly due to the higher hardness and electrical resistivity of the underlying Ni layer. It is well known that ECR is directly related to plating factor, which increases with increasing coating thickness when the electrical resistivity of coating material is more than that of substrate. Surprisingly, in the present case it is found that the ECR decreases with increasing gold layer thickness on OFHC Cu substrate (gold has higher electrical resistivity than OFHC Cu). It is analytically demonstrated from the topography and microhardness measurements results that this peculiar behavior is associated with thin gold platings, where the changes in surface roughness and microhardness with increasing layer thickness overshadow the effect of plating factor on ECR.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Venipuncture-related traumatic neuroma of the ulnar nerve on the dorsal of a hand: A case report. CFTR pharmacology. Editorial For a Brighter Future: Solid State Lighting Influence of Die Attach Layer on Thermal Performance of High Power Light Emitting Diodes Electrical Contact Resistance in Thin $({\leq}{\rm 0.5}~\mu{\rm m})$ Gold Plated Contacts: Effect of Gold Plating Thickness
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1