{"title":"在Moewardi博士的RSUD使用成像板(IP)的千伏峰值测定(kVp)X射线飞机","authors":"Bibit Cahyani, Utari Utari, M. Muhtarom","doi":"10.13057/IJAP.V11I2.45431","DOIUrl":null,"url":null,"abstract":"Research has been carried out to determine the kVp of X-ray aircraft using an imaging plate (IP) as a measuring tool. The imaging plate functions to record images after irradiation and as a detector to capture and store X-ray energy when it penetrates an object. The purpose of this study is to use IP as a kVp measurement tool. The method used is to create a characteristic curve of the relationship between the ratio of Region of Interest (ROI) of two aluminum filters to rated voltage (kVp). From the research obtained the equation y = 2816.61 x2 – 4532.19 x + 1878.65 with R2 = 0.988. The kVp test was carried out using a fluoroscopic X-ray model SM-20HFH. The test results obtained that the measured kVp value at a voltage of 70 kV was 66.21 kV and an error value of 5.41%. While the measured kVp value at 55 kV is 58.95 kV with an error value of -7.18%. These results indicate that IP can be used to measure kVp with an error below the allowable tolerance, namely the max error ≤ of 10%.","PeriodicalId":31930,"journal":{"name":"Indonesian Journal of Applied Physics","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Penentuan Peak Kilovoltage (kVp) Pesawat Sinar-X Dengan Pemanfaatan Imaging Plate (IP) Di RSUD Dr. Moewardi\",\"authors\":\"Bibit Cahyani, Utari Utari, M. Muhtarom\",\"doi\":\"10.13057/IJAP.V11I2.45431\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Research has been carried out to determine the kVp of X-ray aircraft using an imaging plate (IP) as a measuring tool. The imaging plate functions to record images after irradiation and as a detector to capture and store X-ray energy when it penetrates an object. The purpose of this study is to use IP as a kVp measurement tool. The method used is to create a characteristic curve of the relationship between the ratio of Region of Interest (ROI) of two aluminum filters to rated voltage (kVp). From the research obtained the equation y = 2816.61 x2 – 4532.19 x + 1878.65 with R2 = 0.988. The kVp test was carried out using a fluoroscopic X-ray model SM-20HFH. The test results obtained that the measured kVp value at a voltage of 70 kV was 66.21 kV and an error value of 5.41%. While the measured kVp value at 55 kV is 58.95 kV with an error value of -7.18%. These results indicate that IP can be used to measure kVp with an error below the allowable tolerance, namely the max error ≤ of 10%.\",\"PeriodicalId\":31930,\"journal\":{\"name\":\"Indonesian Journal of Applied Physics\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Applied Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13057/IJAP.V11I2.45431\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13057/IJAP.V11I2.45431","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Penentuan Peak Kilovoltage (kVp) Pesawat Sinar-X Dengan Pemanfaatan Imaging Plate (IP) Di RSUD Dr. Moewardi
Research has been carried out to determine the kVp of X-ray aircraft using an imaging plate (IP) as a measuring tool. The imaging plate functions to record images after irradiation and as a detector to capture and store X-ray energy when it penetrates an object. The purpose of this study is to use IP as a kVp measurement tool. The method used is to create a characteristic curve of the relationship between the ratio of Region of Interest (ROI) of two aluminum filters to rated voltage (kVp). From the research obtained the equation y = 2816.61 x2 – 4532.19 x + 1878.65 with R2 = 0.988. The kVp test was carried out using a fluoroscopic X-ray model SM-20HFH. The test results obtained that the measured kVp value at a voltage of 70 kV was 66.21 kV and an error value of 5.41%. While the measured kVp value at 55 kV is 58.95 kV with an error value of -7.18%. These results indicate that IP can be used to measure kVp with an error below the allowable tolerance, namely the max error ≤ of 10%.