{"title":"“上帝之手”气动加压装置在股导管置管止血中的有效性和安全性。","authors":"Sungwon Kim, J. Kwon, Y. Han, Jeung-Sook Kim","doi":"10.5152/dir.2016.15451","DOIUrl":null,"url":null,"abstract":"PURPOSE We aimed to assess the usefulness and safety of the God's Hand pneumatic compression device for hemostasis in patients undergoing percutaneous endovascular procedures via femoral artery. METHODS Two hundred thirty-seven patients in whom hemostasis of femoral catheterization was achieved using a God's Hand pneumatic compression device were enrolled. The patients were divided into group A, those in whom the device was applied for four hours, and group B, those in whom the device was applied for two hours, with an additional two hours of bed rest in both groups. Groups A and B were regrouped to groups A' and B' using the propensity score matching method (n=65, for both). Chi-squared test and logistic regression models were used to analyze the relationship between the complication rate and patient characteristics and procedure-related factors. RESULTS Clinical success was achieved in 216 of 237 patients (91.1%): 63 in group A (84%) and 153 in group B (94.4%); in propensity score matched groups, clinical success was seen in 47 patients in group A' (81.5%) and 62 patients in group B' (95.4%). Group B' showed a higher clinical success rate than group A' (P = 0.028). There were no major complications. In logistic regression models, a negative association was noted between the complication rate and the duration of God's Hand application; however, this association was not statistically significant. CONCLUSION The God's Hand pneumatic compression device is effective and safe for the hemostasis of femoral catheterization, and four hours of bed rest is sufficient for hemostasis in selected patients.","PeriodicalId":50582,"journal":{"name":"Diagnostic and Interventional Radiology","volume":"23 1 1","pages":"49-54"},"PeriodicalIF":2.1000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Usefulness and safety of the \\\"God's Hand\\\" pneumatic compression device for hemostasis in femoral catheterization.\",\"authors\":\"Sungwon Kim, J. Kwon, Y. Han, Jeung-Sook Kim\",\"doi\":\"10.5152/dir.2016.15451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE We aimed to assess the usefulness and safety of the God's Hand pneumatic compression device for hemostasis in patients undergoing percutaneous endovascular procedures via femoral artery. METHODS Two hundred thirty-seven patients in whom hemostasis of femoral catheterization was achieved using a God's Hand pneumatic compression device were enrolled. The patients were divided into group A, those in whom the device was applied for four hours, and group B, those in whom the device was applied for two hours, with an additional two hours of bed rest in both groups. Groups A and B were regrouped to groups A' and B' using the propensity score matching method (n=65, for both). Chi-squared test and logistic regression models were used to analyze the relationship between the complication rate and patient characteristics and procedure-related factors. RESULTS Clinical success was achieved in 216 of 237 patients (91.1%): 63 in group A (84%) and 153 in group B (94.4%); in propensity score matched groups, clinical success was seen in 47 patients in group A' (81.5%) and 62 patients in group B' (95.4%). Group B' showed a higher clinical success rate than group A' (P = 0.028). There were no major complications. In logistic regression models, a negative association was noted between the complication rate and the duration of God's Hand application; however, this association was not statistically significant. CONCLUSION The God's Hand pneumatic compression device is effective and safe for the hemostasis of femoral catheterization, and four hours of bed rest is sufficient for hemostasis in selected patients.\",\"PeriodicalId\":50582,\"journal\":{\"name\":\"Diagnostic and Interventional Radiology\",\"volume\":\"23 1 1\",\"pages\":\"49-54\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and Interventional Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5152/dir.2016.15451\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/dir.2016.15451","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Usefulness and safety of the "God's Hand" pneumatic compression device for hemostasis in femoral catheterization.
PURPOSE We aimed to assess the usefulness and safety of the God's Hand pneumatic compression device for hemostasis in patients undergoing percutaneous endovascular procedures via femoral artery. METHODS Two hundred thirty-seven patients in whom hemostasis of femoral catheterization was achieved using a God's Hand pneumatic compression device were enrolled. The patients were divided into group A, those in whom the device was applied for four hours, and group B, those in whom the device was applied for two hours, with an additional two hours of bed rest in both groups. Groups A and B were regrouped to groups A' and B' using the propensity score matching method (n=65, for both). Chi-squared test and logistic regression models were used to analyze the relationship between the complication rate and patient characteristics and procedure-related factors. RESULTS Clinical success was achieved in 216 of 237 patients (91.1%): 63 in group A (84%) and 153 in group B (94.4%); in propensity score matched groups, clinical success was seen in 47 patients in group A' (81.5%) and 62 patients in group B' (95.4%). Group B' showed a higher clinical success rate than group A' (P = 0.028). There were no major complications. In logistic regression models, a negative association was noted between the complication rate and the duration of God's Hand application; however, this association was not statistically significant. CONCLUSION The God's Hand pneumatic compression device is effective and safe for the hemostasis of femoral catheterization, and four hours of bed rest is sufficient for hemostasis in selected patients.
期刊介绍:
Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English.
The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.