迈向便携式流式细胞术:基于空气护套的体积高效两相微流体系统的研究

D. Huh, A. Tkaczyk, Hsien-Hung Wei, J. Grotberg, S. Takayama
{"title":"迈向便携式流式细胞术:基于空气护套的体积高效两相微流体系统的研究","authors":"D. Huh, A. Tkaczyk, Hsien-Hung Wei, J. Grotberg, S. Takayama","doi":"10.1109/IEMBS.2002.1106579","DOIUrl":null,"url":null,"abstract":"Reports experimental studies on air-liquid two-phase stratified flows in polymeric microfluidic channels for volume-efficient and cost-effective flow cytometry. Different flow behaviors of liquid core streams sheathed by air flows were investigated by varying surface chemistry and geometry of poly(dimethylsiloxane) (PDMS) channels. Fluorescent beads and myoblast cells carried by stable liquid flows were analyzed by a digital photo-multiplier tube (PMT)-based optical detection system to analyze the number of particles in a sample.","PeriodicalId":60385,"journal":{"name":"中国地球物理学会年刊","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2002-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems\",\"authors\":\"D. Huh, A. Tkaczyk, Hsien-Hung Wei, J. Grotberg, S. Takayama\",\"doi\":\"10.1109/IEMBS.2002.1106579\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reports experimental studies on air-liquid two-phase stratified flows in polymeric microfluidic channels for volume-efficient and cost-effective flow cytometry. Different flow behaviors of liquid core streams sheathed by air flows were investigated by varying surface chemistry and geometry of poly(dimethylsiloxane) (PDMS) channels. Fluorescent beads and myoblast cells carried by stable liquid flows were analyzed by a digital photo-multiplier tube (PMT)-based optical detection system to analyze the number of particles in a sample.\",\"PeriodicalId\":60385,\"journal\":{\"name\":\"中国地球物理学会年刊\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国地球物理学会年刊\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.2002.1106579\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国地球物理学会年刊","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/IEMBS.2002.1106579","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

报道了用于高效体积和低成本流式细胞术的聚合微流体通道中气液两相分层流动的实验研究。通过改变聚二甲基硅氧烷(PDMS)通道的表面化学和几何形状,研究了被空气包裹的液芯流的不同流动行为。采用基于数字光倍增管(PMT)的光学检测系统对稳定液体流动携带的荧光珠和成肌细胞进行分析,以分析样品中的颗粒数量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems
Reports experimental studies on air-liquid two-phase stratified flows in polymeric microfluidic channels for volume-efficient and cost-effective flow cytometry. Different flow behaviors of liquid core streams sheathed by air flows were investigated by varying surface chemistry and geometry of poly(dimethylsiloxane) (PDMS) channels. Fluorescent beads and myoblast cells carried by stable liquid flows were analyzed by a digital photo-multiplier tube (PMT)-based optical detection system to analyze the number of particles in a sample.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
368
期刊最新文献
Contour extraction of fetus' head from echocardiogram using Snakes Towards portable flow cytometry: study on the use of air-sheath-based volume-efficient two-phase microfluidic systems Left ventricular volume changes after defibrillation Bifocal technique for accurate measurement of total attenuation coefficient in scattering media with OCT Comparative in vivo and ex vivo pacing and sensing performance study using isolated four-chamber working swine heart model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1