栅极阻抗测量中高频电流数字迟滞控制的开关时间预测

S. Gunter, F. Fuchs
{"title":"栅极阻抗测量中高频电流数字迟滞控制的开关时间预测","authors":"S. Gunter, F. Fuchs","doi":"10.1109/EPE.2014.6910905","DOIUrl":null,"url":null,"abstract":"The measurement of the grid impedance is important for filter and control design, for active filter functionality of grid connected inverters and also for distribution network operators. It supports knowledge of the grid and design of decentralized energy generator power flow. Not only the impedance at fundamental frequency but also the impedance at harmonic and interharmonic frequencies is of common interest. With an inverter injecting a current at an individual frequency onto the power system, the real frequency dependent value of the grid impedance can be determined. A digital hysteresis current control is a promising method to control a voltage source inverter (VSI) for high frequency current generation in grid impedance measurement application. Digital signal processing is state of the art, but the speed of the analog to digital conversion is limited. When using hysteresis current control the outcome of this is that the current leaves the defined hysteresis band because of the time discrete sampling. In this paper a method using switching time prediction to minimize this current overshoot is proposed and analyzed. Simulation and measurement results are presented that show the suitability of this method.","PeriodicalId":6508,"journal":{"name":"2014 16th European Conference on Power Electronics and Applications","volume":"5 1","pages":"1-8"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Switching time prediction for digital hysteresis control for high frequency current in grid impedance measurement application\",\"authors\":\"S. Gunter, F. Fuchs\",\"doi\":\"10.1109/EPE.2014.6910905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The measurement of the grid impedance is important for filter and control design, for active filter functionality of grid connected inverters and also for distribution network operators. It supports knowledge of the grid and design of decentralized energy generator power flow. Not only the impedance at fundamental frequency but also the impedance at harmonic and interharmonic frequencies is of common interest. With an inverter injecting a current at an individual frequency onto the power system, the real frequency dependent value of the grid impedance can be determined. A digital hysteresis current control is a promising method to control a voltage source inverter (VSI) for high frequency current generation in grid impedance measurement application. Digital signal processing is state of the art, but the speed of the analog to digital conversion is limited. When using hysteresis current control the outcome of this is that the current leaves the defined hysteresis band because of the time discrete sampling. In this paper a method using switching time prediction to minimize this current overshoot is proposed and analyzed. Simulation and measurement results are presented that show the suitability of this method.\",\"PeriodicalId\":6508,\"journal\":{\"name\":\"2014 16th European Conference on Power Electronics and Applications\",\"volume\":\"5 1\",\"pages\":\"1-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 16th European Conference on Power Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2014.6910905\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 16th European Conference on Power Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2014.6910905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

电网阻抗的测量对于滤波器和控制设计、并网逆变器的有源滤波器功能以及配电网运营商都很重要。它支持电网知识和分散式能源发电机潮流设计。不仅基频阻抗,谐波和间谐波阻抗也是人们共同关心的问题。通过逆变器向电力系统注入某一频率的电流,可以确定电网阻抗的实际频率相关值。数字迟滞电流控制是控制电压源逆变器高频电流产生的一种很有前途的方法。数字信号处理是最先进的,但模拟到数字转换的速度是有限的。当使用迟滞电流控制时,由于时间离散采样,其结果是电流离开定义的迟滞带。本文提出并分析了一种利用开关时间预测最小化电流超调的方法。仿真和实测结果表明了该方法的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Switching time prediction for digital hysteresis control for high frequency current in grid impedance measurement application
The measurement of the grid impedance is important for filter and control design, for active filter functionality of grid connected inverters and also for distribution network operators. It supports knowledge of the grid and design of decentralized energy generator power flow. Not only the impedance at fundamental frequency but also the impedance at harmonic and interharmonic frequencies is of common interest. With an inverter injecting a current at an individual frequency onto the power system, the real frequency dependent value of the grid impedance can be determined. A digital hysteresis current control is a promising method to control a voltage source inverter (VSI) for high frequency current generation in grid impedance measurement application. Digital signal processing is state of the art, but the speed of the analog to digital conversion is limited. When using hysteresis current control the outcome of this is that the current leaves the defined hysteresis band because of the time discrete sampling. In this paper a method using switching time prediction to minimize this current overshoot is proposed and analyzed. Simulation and measurement results are presented that show the suitability of this method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modeling of turn-OFF transient energy in IGBT controlled silicon PiN diodes Multi-reference frame based PLL for single phase systems in voltage distorted grids New aspects on analyzing ZVS conditions for converters using super-junction Si and wide bandgap SiC and GaN power FETs Unidirectional fast switching non-isolated 100 kW fuel cell boost converter Obal optimization of hybrid electrical system to decrease fuel consumption or operating cost
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1