数字蓝光对眼睛影响的证据:范围综述

A. Munsamy, Macaela Moodley, Zainab Khan, Keroshni Govender, Mpendulo Nkwanyana, Siphosethu Cele, Mashiyamahle Radebe
{"title":"数字蓝光对眼睛影响的证据:范围综述","authors":"A. Munsamy, Macaela Moodley, Zainab Khan, Keroshni Govender, Mpendulo Nkwanyana, Siphosethu Cele, Mashiyamahle Radebe","doi":"10.4102/aveh.v81i1.685","DOIUrl":null,"url":null,"abstract":"Background: Digital blue light is the blue light emitted from light emitting diode (LED) displays, which may be regarded as a health hazard to our eyes and vision.Aim: This review sought to map out evidence on the effects of blue light on the eye from digital devices.Methods: The study design is a scoping review. Peer-reviewed studies published in the last 25 years were sourced from Google Scholar, PubMed, Cochrane and Medline databases. Data were extracted using the relevant search terms followed by thematic analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) framework was utilised to report this process. The Mixed Method Appraisal Tool (MMAT) assessed the quality of included studies.Results: Thirty-seven articles met the eligibility criteria. After the full-text screening, the exclusion of 32 articles resulted in five articles to map. The majority of studies included the indirect measuring of the effects of digital blue light using blue-blocking spectacles on blink rate, critical flicker frequency, near point of convergence and eyestrain. The central theme identified across mapped studies regarding the effects of digital blue light was its role in resultant visual discomfort. Of the five accepted studies, three studies had an MMAT score of 100%, whilst two studies scored 80%, suggesting that their results were reliable.Conclusion: The review concluded that blocking short-wavelength blue light reduced visual discomfort or digital eyestrain. The gap identified was a lack of research on the exposure of digital blue light on the retina in human eyes in vivo and required more investigations to corroborate the animal studies.","PeriodicalId":7694,"journal":{"name":"African Vision and Eye Health","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evidence on the effects of digital blue light on the eye: A scoping review\",\"authors\":\"A. Munsamy, Macaela Moodley, Zainab Khan, Keroshni Govender, Mpendulo Nkwanyana, Siphosethu Cele, Mashiyamahle Radebe\",\"doi\":\"10.4102/aveh.v81i1.685\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Digital blue light is the blue light emitted from light emitting diode (LED) displays, which may be regarded as a health hazard to our eyes and vision.Aim: This review sought to map out evidence on the effects of blue light on the eye from digital devices.Methods: The study design is a scoping review. Peer-reviewed studies published in the last 25 years were sourced from Google Scholar, PubMed, Cochrane and Medline databases. Data were extracted using the relevant search terms followed by thematic analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) framework was utilised to report this process. The Mixed Method Appraisal Tool (MMAT) assessed the quality of included studies.Results: Thirty-seven articles met the eligibility criteria. After the full-text screening, the exclusion of 32 articles resulted in five articles to map. The majority of studies included the indirect measuring of the effects of digital blue light using blue-blocking spectacles on blink rate, critical flicker frequency, near point of convergence and eyestrain. The central theme identified across mapped studies regarding the effects of digital blue light was its role in resultant visual discomfort. Of the five accepted studies, three studies had an MMAT score of 100%, whilst two studies scored 80%, suggesting that their results were reliable.Conclusion: The review concluded that blocking short-wavelength blue light reduced visual discomfort or digital eyestrain. The gap identified was a lack of research on the exposure of digital blue light on the retina in human eyes in vivo and required more investigations to corroborate the animal studies.\",\"PeriodicalId\":7694,\"journal\":{\"name\":\"African Vision and Eye Health\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Vision and Eye Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/aveh.v81i1.685\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Vision and Eye Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/aveh.v81i1.685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:数字蓝光是发光二极管(LED)显示器发出的蓝光,可能会对我们的眼睛和视力造成健康危害。目的:本综述试图找出数字设备产生的蓝光对眼睛影响的证据。方法:本研究设计为范围综述。过去25年发表的同行评议研究来自Google Scholar、PubMed、Cochrane和Medline数据库。使用相关搜索词提取数据,然后进行专题分析。系统评价和荟萃分析的首选报告项目(PRISMA)框架被用来报告这一过程。混合方法评价工具(MMAT)评估纳入研究的质量。结果:37篇文章符合入选标准。全文筛选后,32篇文章被排除,只有5篇文章被纳入图谱。大多数研究包括间接测量数字蓝光对眨眼频率、临界闪烁频率、近汇聚点和眼睛疲劳的影响。关于数字蓝光影响的地图研究确定的中心主题是它在由此产生的视觉不适中的作用。在被接受的5项研究中,3项研究的MMAT得分为100%,而2项研究的MMAT得分为80%,这表明他们的结果是可靠的。结论:本综述认为,阻挡短波蓝光可减少视觉不适或数字眼疲劳。所发现的差距是缺乏关于人眼视网膜在体内暴露数字蓝光的研究,需要更多的调查来证实动物研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evidence on the effects of digital blue light on the eye: A scoping review
Background: Digital blue light is the blue light emitted from light emitting diode (LED) displays, which may be regarded as a health hazard to our eyes and vision.Aim: This review sought to map out evidence on the effects of blue light on the eye from digital devices.Methods: The study design is a scoping review. Peer-reviewed studies published in the last 25 years were sourced from Google Scholar, PubMed, Cochrane and Medline databases. Data were extracted using the relevant search terms followed by thematic analysis. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) framework was utilised to report this process. The Mixed Method Appraisal Tool (MMAT) assessed the quality of included studies.Results: Thirty-seven articles met the eligibility criteria. After the full-text screening, the exclusion of 32 articles resulted in five articles to map. The majority of studies included the indirect measuring of the effects of digital blue light using blue-blocking spectacles on blink rate, critical flicker frequency, near point of convergence and eyestrain. The central theme identified across mapped studies regarding the effects of digital blue light was its role in resultant visual discomfort. Of the five accepted studies, three studies had an MMAT score of 100%, whilst two studies scored 80%, suggesting that their results were reliable.Conclusion: The review concluded that blocking short-wavelength blue light reduced visual discomfort or digital eyestrain. The gap identified was a lack of research on the exposure of digital blue light on the retina in human eyes in vivo and required more investigations to corroborate the animal studies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
African Vision and Eye Health
African Vision and Eye Health Health Professions-Optometry
CiteScore
1.00
自引率
0.00%
发文量
46
期刊最新文献
Optometrists’ perspectives on speciality programme development in South Africa Pathophysiology of dry eye disease and novel therapeutic agents Impact of spectacle wear on the quality of life of learners with hearing impairment in Ghana Clinical characteristics and associated factors of diabetic retinopathy in Sudanese patients Refractive error accuracy and user perceptions of a smartphone home-based tester
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1