Joong-Hyun Kim, Sung-Taeg Kang, Seung-Gon Lee, Hakmin Lee, D. Jeong, Jaehyoung Park, Seung-Ki Lee
{"title":"结合微流体通道的光纤局部表面等离子体共振传感器","authors":"Joong-Hyun Kim, Sung-Taeg Kang, Seung-Gon Lee, Hakmin Lee, D. Jeong, Jaehyoung Park, Seung-Ki Lee","doi":"10.1109/TRANSDUCERS.2015.7180912","DOIUrl":null,"url":null,"abstract":"This paper proposes Fiber-Optic Localized Surface Plasmon Resonance (FO LSPR) sensor combined with micro fluidic channel, which enables the continuous supply of fluid for bio-reaction. The proposed method can prevent the degradation of the sensing characteristics due to the change of measurement condition. The feasibility of the FO LSPR sensor with micro fluidic channel is proved by Computational Fluid Dynamics simulation (CFD). Also, the proposed method has been evidenced by measuring the output intensity of the FO LSPR sensor at various refractive index solutions. Finally, Prostate Specific Antigen (PSA) immunoassay was measured to verify the possibility of the fabricated sensor system as a biosensor.","PeriodicalId":6465,"journal":{"name":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"49","resultStr":"{\"title\":\"Fiber-Optic Localized Surface Plasmon Resonance sensor combined with micro fluidic channel\",\"authors\":\"Joong-Hyun Kim, Sung-Taeg Kang, Seung-Gon Lee, Hakmin Lee, D. Jeong, Jaehyoung Park, Seung-Ki Lee\",\"doi\":\"10.1109/TRANSDUCERS.2015.7180912\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes Fiber-Optic Localized Surface Plasmon Resonance (FO LSPR) sensor combined with micro fluidic channel, which enables the continuous supply of fluid for bio-reaction. The proposed method can prevent the degradation of the sensing characteristics due to the change of measurement condition. The feasibility of the FO LSPR sensor with micro fluidic channel is proved by Computational Fluid Dynamics simulation (CFD). Also, the proposed method has been evidenced by measuring the output intensity of the FO LSPR sensor at various refractive index solutions. Finally, Prostate Specific Antigen (PSA) immunoassay was measured to verify the possibility of the fabricated sensor system as a biosensor.\",\"PeriodicalId\":6465,\"journal\":{\"name\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"49\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2015.7180912\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2015.7180912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
This paper proposes Fiber-Optic Localized Surface Plasmon Resonance (FO LSPR) sensor combined with micro fluidic channel, which enables the continuous supply of fluid for bio-reaction. The proposed method can prevent the degradation of the sensing characteristics due to the change of measurement condition. The feasibility of the FO LSPR sensor with micro fluidic channel is proved by Computational Fluid Dynamics simulation (CFD). Also, the proposed method has been evidenced by measuring the output intensity of the FO LSPR sensor at various refractive index solutions. Finally, Prostate Specific Antigen (PSA) immunoassay was measured to verify the possibility of the fabricated sensor system as a biosensor.