新型干涉测量x射线列阵长度的方法及装置

H. R. Drmeyan, S. Mkhitaryan
{"title":"新型干涉测量x射线列阵长度的方法及装置","authors":"H. R. Drmeyan, S. Mkhitaryan","doi":"10.5539/jmsr.v11n1p85","DOIUrl":null,"url":null,"abstract":"A new interferometric method for measuring the length of the X-ray train is proposed, and a special interferometer, a device for measurement of the X-ray train length has been developed, created, and tested. The length of the X-ray train and the duration of coherent radiation are estimated and it has been proven that the interference pattern disappears when the difference of paths between the superimposing waves becomes greater than the length of the coherent X-ray train. The bound of a disappearance of the X-ray interference pattern is determined depending on the magnitude of the path differences. The length of the X-ray train is determined, which is close to the theoretically determined value.","PeriodicalId":16111,"journal":{"name":"Journal of Materials Science Research","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"New Interferometric Method and Device for Measuring the X-Ray Train Length\",\"authors\":\"H. R. Drmeyan, S. Mkhitaryan\",\"doi\":\"10.5539/jmsr.v11n1p85\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new interferometric method for measuring the length of the X-ray train is proposed, and a special interferometer, a device for measurement of the X-ray train length has been developed, created, and tested. The length of the X-ray train and the duration of coherent radiation are estimated and it has been proven that the interference pattern disappears when the difference of paths between the superimposing waves becomes greater than the length of the coherent X-ray train. The bound of a disappearance of the X-ray interference pattern is determined depending on the magnitude of the path differences. The length of the X-ray train is determined, which is close to the theoretically determined value.\",\"PeriodicalId\":16111,\"journal\":{\"name\":\"Journal of Materials Science Research\",\"volume\":\"20 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Materials Science Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5539/jmsr.v11n1p85\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5539/jmsr.v11n1p85","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种新的测量x射线列列长度的干涉仪方法,研制了一种专用的测量x射线列列长度的干涉仪,并进行了试验。估计了x射线序列的长度和相干辐射的持续时间,并证明了当叠加波之间的路径差大于相干x射线序列的长度时,干涉图样消失。x射线干涉图样消失的边界取决于路径差的大小。确定了x射线序列的长度,该长度接近于理论确定的值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New Interferometric Method and Device for Measuring the X-Ray Train Length
A new interferometric method for measuring the length of the X-ray train is proposed, and a special interferometer, a device for measurement of the X-ray train length has been developed, created, and tested. The length of the X-ray train and the duration of coherent radiation are estimated and it has been proven that the interference pattern disappears when the difference of paths between the superimposing waves becomes greater than the length of the coherent X-ray train. The bound of a disappearance of the X-ray interference pattern is determined depending on the magnitude of the path differences. The length of the X-ray train is determined, which is close to the theoretically determined value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Structural and Electronic Impact on Various Substrates of TiO2 Thin Film Using Sol-Gel Spin Coating Method On the Onset of Plasticity: Determination of Strength and Ductility Investigation to enhanced Physical and Mechanical Properties of Road Pavement in Asphalt Incorporating Low-Density Waste Plastic Bags Reviewer acknowledgements for Journal of Materials Science Research, Vol. 12, No. 2 Electron Theory of Metals - Answers to Unsolved Problems/Questions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1