超快速三维PET图像重建使用高度压缩,内存驻留系统矩阵与优化的SIMD访问模式

J. Scheins, L. Tellmann, C. Weirich, E. R. Kops, H. Herzog
{"title":"超快速三维PET图像重建使用高度压缩,内存驻留系统矩阵与优化的SIMD访问模式","authors":"J. Scheins, L. Tellmann, C. Weirich, E. R. Kops, H. Herzog","doi":"10.1109/NSSMIC.2010.5874222","DOIUrl":null,"url":null,"abstract":"Fully 3D PET image reconstruction for large detector systems still remains a challenging computational task due to the tremendous number of Lines-of-Response. The reconstruction software PRESTO (PET REconstruction Software TOolkit) allows to use accurate geometrical weighting schemes for the forward/backward projection, e.g. Volume-of-Intersection, while using all measured LORs separately. PRESTO exploits matrix redundancies to realise a strongly compressed, memory-resident system matrix. In this way, the needed time to calculate matrix weights no longer influences the reconstruction time. Nevertheless, in the first implementation the addressing of matrix weights, projection values and voxel values in disfavoured memory access patterns caused severe computational inefficiencies due to the limited memory bandwidth. In this work, the image data and projection data in memory as well as the order of mathematical operations have been re-organised to provide an optimal merit for the Single Instruction Multiple Data (SIMD) approach. A global speedup factor of 15 for has been achieved while obtaining identical results.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"9 1","pages":"2420-2422"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Ultra fast 3-D PET image reconstruction using highly compressed, memory-resident system matrices with optimised SIMD access patterns\",\"authors\":\"J. Scheins, L. Tellmann, C. Weirich, E. R. Kops, H. Herzog\",\"doi\":\"10.1109/NSSMIC.2010.5874222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fully 3D PET image reconstruction for large detector systems still remains a challenging computational task due to the tremendous number of Lines-of-Response. The reconstruction software PRESTO (PET REconstruction Software TOolkit) allows to use accurate geometrical weighting schemes for the forward/backward projection, e.g. Volume-of-Intersection, while using all measured LORs separately. PRESTO exploits matrix redundancies to realise a strongly compressed, memory-resident system matrix. In this way, the needed time to calculate matrix weights no longer influences the reconstruction time. Nevertheless, in the first implementation the addressing of matrix weights, projection values and voxel values in disfavoured memory access patterns caused severe computational inefficiencies due to the limited memory bandwidth. In this work, the image data and projection data in memory as well as the order of mathematical operations have been re-organised to provide an optimal merit for the Single Instruction Multiple Data (SIMD) approach. A global speedup factor of 15 for has been achieved while obtaining identical results.\",\"PeriodicalId\":13048,\"journal\":{\"name\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"volume\":\"9 1\",\"pages\":\"2420-2422\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2010.5874222\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于响应线数量巨大,大型探测器系统的全三维PET图像重建仍然是一项具有挑战性的计算任务。重建软件PRESTO (PET重建软件工具包)允许使用精确的几何加权方案进行前/后投影,例如相交体积,同时单独使用所有测量的LORs。PRESTO利用矩阵冗余来实现一个强压缩、内存驻留的系统矩阵。这样,计算矩阵权值所需的时间不再影响重构时间。然而,在第一个实现中,由于有限的内存带宽,在不利的内存访问模式中对矩阵权重、投影值和体素值进行寻址导致了严重的计算效率低下。在这项工作中,内存中的图像数据和投影数据以及数学运算顺序被重新组织,以提供单指令多数据(SIMD)方法的最佳优点。在获得相同结果的情况下,实现了15倍的全局加速因子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultra fast 3-D PET image reconstruction using highly compressed, memory-resident system matrices with optimised SIMD access patterns
Fully 3D PET image reconstruction for large detector systems still remains a challenging computational task due to the tremendous number of Lines-of-Response. The reconstruction software PRESTO (PET REconstruction Software TOolkit) allows to use accurate geometrical weighting schemes for the forward/backward projection, e.g. Volume-of-Intersection, while using all measured LORs separately. PRESTO exploits matrix redundancies to realise a strongly compressed, memory-resident system matrix. In this way, the needed time to calculate matrix weights no longer influences the reconstruction time. Nevertheless, in the first implementation the addressing of matrix weights, projection values and voxel values in disfavoured memory access patterns caused severe computational inefficiencies due to the limited memory bandwidth. In this work, the image data and projection data in memory as well as the order of mathematical operations have been re-organised to provide an optimal merit for the Single Instruction Multiple Data (SIMD) approach. A global speedup factor of 15 for has been achieved while obtaining identical results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CaF2(Eu): An “Old” scintillator revisited Evaluation of the accuracy and robustness of a motion correction algorithm for PET using a novel phantom approach The performance of GridPix detectors Applying the neutron scatter camera to treaty verification and warhead monitoring Development of an 8-channel time based readout ASIC for PET applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1