GEANT4版本8.2和9.2在pCT简化校准曲线方面的比较

O. Yevseyeva, Joaquim Teixeira de Assis, E. Milhoretto, I. Evseev, H. Schelin, F. Ahmann, S. Paschuk, J. Setti, V. Denyak, K. S. Diaz, J. M. Hormaza, R. Lopes
{"title":"GEANT4版本8.2和9.2在pCT简化校准曲线方面的比较","authors":"O. Yevseyeva, Joaquim Teixeira de Assis, E. Milhoretto, I. Evseev, H. Schelin, F. Ahmann, S. Paschuk, J. Setti, V. Denyak, K. S. Diaz, J. M. Hormaza, R. Lopes","doi":"10.1109/NSSMIC.2010.5874220","DOIUrl":null,"url":null,"abstract":"The GEANT4 simulations are essential for the development of medical tomography with proton beams — pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with the results of other popular Monte Carlo codes like TRIM/SRIM, or MCNPX. For thick absorbers, however, the disagreements became evident. In a part, these disagreements are due to the known contradictions in the NIST PSTAR and SRIM reference data. Therefore, it is interesting to compare the GEANT4 results with each other, with experiment, and with diverse code results in a reduced form, which is free from this kind of doubts. In this work such comparison is done within the Reduced Calibration Curve concept elaborated for the proton beam tomography.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"109 1","pages":"2413-2417"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparison of the GEANT4 releases 8.2 and 9.2 in terms of a pCT reduced calibration curve\",\"authors\":\"O. Yevseyeva, Joaquim Teixeira de Assis, E. Milhoretto, I. Evseev, H. Schelin, F. Ahmann, S. Paschuk, J. Setti, V. Denyak, K. S. Diaz, J. M. Hormaza, R. Lopes\",\"doi\":\"10.1109/NSSMIC.2010.5874220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The GEANT4 simulations are essential for the development of medical tomography with proton beams — pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with the results of other popular Monte Carlo codes like TRIM/SRIM, or MCNPX. For thick absorbers, however, the disagreements became evident. In a part, these disagreements are due to the known contradictions in the NIST PSTAR and SRIM reference data. Therefore, it is interesting to compare the GEANT4 results with each other, with experiment, and with diverse code results in a reduced form, which is free from this kind of doubts. In this work such comparison is done within the Reduced Calibration Curve concept elaborated for the proton beam tomography.\",\"PeriodicalId\":13048,\"journal\":{\"name\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"volume\":\"109 1\",\"pages\":\"2413-2417\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2010.5874220\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

GEANT4模拟对于质子束医学断层扫描(pCT)的发展至关重要。在薄吸收体的情况下,最新版本的GEANT4生成非常相似的最终光谱,与其他流行的蒙特卡罗代码(如TRIM/SRIM或MCNPX)的结果非常一致。然而,对于吸收能力强的人来说,分歧变得很明显。在某种程度上,这些分歧是由于NIST PSTAR和SRIM参考数据中已知的矛盾。因此,将GEANT4结果与其他结果、与实验结果以及与各种简化形式的代码结果进行比较是很有趣的,这样就不会有这种疑问。在这项工作中,这种比较是在质子束断层成像的简化校准曲线概念内完成的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the GEANT4 releases 8.2 and 9.2 in terms of a pCT reduced calibration curve
The GEANT4 simulations are essential for the development of medical tomography with proton beams — pCT. In the case of thin absorbers the latest releases of GEANT4 generate very similar final spectra which agree well with the results of other popular Monte Carlo codes like TRIM/SRIM, or MCNPX. For thick absorbers, however, the disagreements became evident. In a part, these disagreements are due to the known contradictions in the NIST PSTAR and SRIM reference data. Therefore, it is interesting to compare the GEANT4 results with each other, with experiment, and with diverse code results in a reduced form, which is free from this kind of doubts. In this work such comparison is done within the Reduced Calibration Curve concept elaborated for the proton beam tomography.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
CaF2(Eu): An “Old” scintillator revisited Evaluation of the accuracy and robustness of a motion correction algorithm for PET using a novel phantom approach The performance of GridPix detectors Applying the neutron scatter camera to treaty verification and warhead monitoring Development of an 8-channel time based readout ASIC for PET applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1