{"title":"基于观测器的LCL滤波器并网变流器主动阻尼","authors":"Y. Zhang, M. Roes, M. Hendrix, J. Duarte","doi":"10.23919/IPEC.2018.8507657","DOIUrl":null,"url":null,"abstract":"In this paper an add-on control method is proposed to damp oscillations in the LCL filter of a grid-connected converter. An observer is used to estimate the capacitor current, and successively, a conventional active damping technique is applied. Since the capacitor current is estimated from already available measurements, the proposed active damping method does not need an extra current sensor for the capacitor current. Model analysis and simulation validate the effectiveness of the proposed control method.","PeriodicalId":6610,"journal":{"name":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","volume":"18 1","pages":"2697-2702"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Observer-based active damping for grid-connected converters with LCL filter\",\"authors\":\"Y. Zhang, M. Roes, M. Hendrix, J. Duarte\",\"doi\":\"10.23919/IPEC.2018.8507657\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper an add-on control method is proposed to damp oscillations in the LCL filter of a grid-connected converter. An observer is used to estimate the capacitor current, and successively, a conventional active damping technique is applied. Since the capacitor current is estimated from already available measurements, the proposed active damping method does not need an extra current sensor for the capacitor current. Model analysis and simulation validate the effectiveness of the proposed control method.\",\"PeriodicalId\":6610,\"journal\":{\"name\":\"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)\",\"volume\":\"18 1\",\"pages\":\"2697-2702\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/IPEC.2018.8507657\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/IPEC.2018.8507657","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Observer-based active damping for grid-connected converters with LCL filter
In this paper an add-on control method is proposed to damp oscillations in the LCL filter of a grid-connected converter. An observer is used to estimate the capacitor current, and successively, a conventional active damping technique is applied. Since the capacitor current is estimated from already available measurements, the proposed active damping method does not need an extra current sensor for the capacitor current. Model analysis and simulation validate the effectiveness of the proposed control method.