用于对映选择性分析甲状腺激素(+)-3,3 ',5-三碘- 1 -甲状腺原氨酸(t3)和(+)-3,3 ',5,5 ' -四碘- 1 -甲状腺原氨酸(t4)的生物传感器

H. Aboul‐Enein, Stefan Raluca-Ioana, S. Lițescu, G. Radu
{"title":"用于对映选择性分析甲状腺激素(+)-3,3 ',5-三碘- 1 -甲状腺原氨酸(t3)和(+)-3,3 ',5,5 ' -四碘- 1 -甲状腺原氨酸(t4)的生物传感器","authors":"H. Aboul‐Enein, Stefan Raluca-Ioana, S. Lițescu, G. Radu","doi":"10.1081/IAS-120003660","DOIUrl":null,"url":null,"abstract":"ABSTRACT An amperometric biosensor based on L-aminoacid oxidase is proposed for enantioselective assay of (+)-3,3′,5-triiodo-L-thyronine (L-T3) and (+)-3,3′,5,5′-tetraiodo-L-thyronine (L-T4), due to the fact that only the L enantiomer has the hormonal activity. The construction of the amperometric biosensor is simple and reproducible. The analytical information obtained from enantioselective analysis are reliable. The RSD <1% assured by using the amperometric biosensors for L enantiomers assay as raw materials, and from tablets, demonstrated their suitability for the analysis of T3 and T4 at ppb concentration levels.","PeriodicalId":15987,"journal":{"name":"Journal of Immunoassay and Immunochemistry","volume":"600 1","pages":"181 - 190"},"PeriodicalIF":0.0000,"publicationDate":"2002-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"BIOSENSOR FOR THE ENANTIOSELECTIVE ANALYSIS OF THE THYROID HORMONES (+)-3,3′,5-TRIIODO-L-THYRONINE (T3) AND (+)-3,3′,5,5′-TETRAIODO-L-THYRONINE (T4)\",\"authors\":\"H. Aboul‐Enein, Stefan Raluca-Ioana, S. Lițescu, G. Radu\",\"doi\":\"10.1081/IAS-120003660\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT An amperometric biosensor based on L-aminoacid oxidase is proposed for enantioselective assay of (+)-3,3′,5-triiodo-L-thyronine (L-T3) and (+)-3,3′,5,5′-tetraiodo-L-thyronine (L-T4), due to the fact that only the L enantiomer has the hormonal activity. The construction of the amperometric biosensor is simple and reproducible. The analytical information obtained from enantioselective analysis are reliable. The RSD <1% assured by using the amperometric biosensors for L enantiomers assay as raw materials, and from tablets, demonstrated their suitability for the analysis of T3 and T4 at ppb concentration levels.\",\"PeriodicalId\":15987,\"journal\":{\"name\":\"Journal of Immunoassay and Immunochemistry\",\"volume\":\"600 1\",\"pages\":\"181 - 190\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Immunoassay and Immunochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1081/IAS-120003660\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Immunoassay and Immunochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1081/IAS-120003660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

摘要:由于只有L对映体具有激素活性,提出了一种基于L-氨基酸氧化酶的电流型生物传感器,用于(+)-3,3 ',5-三碘-L-甲状腺原氨酸(L- t3)和(+)-3,3 ',5,5 ' -四碘-L-甲状腺原氨酸(L- t4)的对映选择性测定。该安培型生物传感器结构简单,重复性好。对映选择分析得到的分析信息是可靠的。以L对映体测定为原料的安培生物传感器和片剂的RSD均<1%,证明其适用于ppb浓度水平下的T3和T4的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
BIOSENSOR FOR THE ENANTIOSELECTIVE ANALYSIS OF THE THYROID HORMONES (+)-3,3′,5-TRIIODO-L-THYRONINE (T3) AND (+)-3,3′,5,5′-TETRAIODO-L-THYRONINE (T4)
ABSTRACT An amperometric biosensor based on L-aminoacid oxidase is proposed for enantioselective assay of (+)-3,3′,5-triiodo-L-thyronine (L-T3) and (+)-3,3′,5,5′-tetraiodo-L-thyronine (L-T4), due to the fact that only the L enantiomer has the hormonal activity. The construction of the amperometric biosensor is simple and reproducible. The analytical information obtained from enantioselective analysis are reliable. The RSD <1% assured by using the amperometric biosensors for L enantiomers assay as raw materials, and from tablets, demonstrated their suitability for the analysis of T3 and T4 at ppb concentration levels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modulation of acute stress and immune response in tilapia, Oreochromis niloticus, using longevity spinach, Gynura procumbens extract, as nutraceuticals Survey of the association between polymorphisms of CTLA-4 exon 1 49 A/G genes with rheumatoid arthritis in Iran Winner of the 2021 Journal of Immunoassay & Immunochemistry Early Career Research Prize Evidence of hepatitis B infection and co-infection with enteric fever among febrile patients in a primary health facility in Kogi State, Nigeria Medullary thyroid carcinoma diagnosed with liquid-based cytology and immunocytochemistry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1