{"title":"单源和双源CT的三piccs","authors":"C. Maas, C. Hofmann, M. Kachelries","doi":"10.1109/NSSMIC.2010.5874304","DOIUrl":null,"url":null,"abstract":"Recently, temporal resolution improved prior image constrained compressed sensing (TRI-PICCS), an algorithm promising improved temporal resolution in cardiac CT, was proposed. Here, we extend the ideas to dual source CT. Single source and dual source CT simulations of a heart phantom as well as a single source cardiac CT measurement are used to evaluate the temporal resolution of CT images reconstructed with TRI-PICCS. Short scan reconstructions of the same data are used for comparison. The result of this study is that there seems to be an advantage in temporal resolution when using TRI-PICCS, however, this impression is actually caused by a slight shift of the motion phase when using TRI-PICCS. Comparing short scan reconstructions and TRI-PICCS reconstructions at the same motion phase, no temporal resolution improvement could be confirmed.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"22 1","pages":"2805-2810"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"TRI-PICCS in single source and dual source CT\",\"authors\":\"C. Maas, C. Hofmann, M. Kachelries\",\"doi\":\"10.1109/NSSMIC.2010.5874304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recently, temporal resolution improved prior image constrained compressed sensing (TRI-PICCS), an algorithm promising improved temporal resolution in cardiac CT, was proposed. Here, we extend the ideas to dual source CT. Single source and dual source CT simulations of a heart phantom as well as a single source cardiac CT measurement are used to evaluate the temporal resolution of CT images reconstructed with TRI-PICCS. Short scan reconstructions of the same data are used for comparison. The result of this study is that there seems to be an advantage in temporal resolution when using TRI-PICCS, however, this impression is actually caused by a slight shift of the motion phase when using TRI-PICCS. Comparing short scan reconstructions and TRI-PICCS reconstructions at the same motion phase, no temporal resolution improvement could be confirmed.\",\"PeriodicalId\":13048,\"journal\":{\"name\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"volume\":\"22 1\",\"pages\":\"2805-2810\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Nuclear Science Symposuim & Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2010.5874304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2010.5874304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Recently, temporal resolution improved prior image constrained compressed sensing (TRI-PICCS), an algorithm promising improved temporal resolution in cardiac CT, was proposed. Here, we extend the ideas to dual source CT. Single source and dual source CT simulations of a heart phantom as well as a single source cardiac CT measurement are used to evaluate the temporal resolution of CT images reconstructed with TRI-PICCS. Short scan reconstructions of the same data are used for comparison. The result of this study is that there seems to be an advantage in temporal resolution when using TRI-PICCS, however, this impression is actually caused by a slight shift of the motion phase when using TRI-PICCS. Comparing short scan reconstructions and TRI-PICCS reconstructions at the same motion phase, no temporal resolution improvement could be confirmed.