M. Takahashi, Y. Heo, T. Kawanishi, T. Okitsu, S. Takeuchi
{"title":"可植入荧光水凝胶微纤维的便携式连续血糖监测系统","authors":"M. Takahashi, Y. Heo, T. Kawanishi, T. Okitsu, S. Takeuchi","doi":"10.1109/MEMSYS.2013.6474439","DOIUrl":null,"url":null,"abstract":"We present a portable glucose monitoring system comprised of an implantable fluorescent-hydrogel sensor, wearable photo detector, microcontroller, wireless device and software for transdermal, continuous glucose monitoring. Although we showed the potential of the fluorescent-hydrogel fibers for applying to long-term, implanted glucose monitoring, “true” continuous glucose monitoring with a portable monitoring system has yet to be realized. In the system that we propose here, the calculated glucose values show a good correlation with the actual blood glucose concentrations. The portable device attached to the ear of a rat and measured the fluorescence intensity for three days. Therefore, our system shows the potential for practical, “true,” continuous glucose monitoring.","PeriodicalId":92162,"journal":{"name":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","volume":"86 1","pages":"1089-1092"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Portable continuous glucose monitoring systems with implantable fluorescent hydrogel microfibers\",\"authors\":\"M. Takahashi, Y. Heo, T. Kawanishi, T. Okitsu, S. Takeuchi\",\"doi\":\"10.1109/MEMSYS.2013.6474439\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present a portable glucose monitoring system comprised of an implantable fluorescent-hydrogel sensor, wearable photo detector, microcontroller, wireless device and software for transdermal, continuous glucose monitoring. Although we showed the potential of the fluorescent-hydrogel fibers for applying to long-term, implanted glucose monitoring, “true” continuous glucose monitoring with a portable monitoring system has yet to be realized. In the system that we propose here, the calculated glucose values show a good correlation with the actual blood glucose concentrations. The portable device attached to the ear of a rat and measured the fluorescence intensity for three days. Therefore, our system shows the potential for practical, “true,” continuous glucose monitoring.\",\"PeriodicalId\":92162,\"journal\":{\"name\":\"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)\",\"volume\":\"86 1\",\"pages\":\"1089-1092\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.2013.6474439\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2013.6474439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Portable continuous glucose monitoring systems with implantable fluorescent hydrogel microfibers
We present a portable glucose monitoring system comprised of an implantable fluorescent-hydrogel sensor, wearable photo detector, microcontroller, wireless device and software for transdermal, continuous glucose monitoring. Although we showed the potential of the fluorescent-hydrogel fibers for applying to long-term, implanted glucose monitoring, “true” continuous glucose monitoring with a portable monitoring system has yet to be realized. In the system that we propose here, the calculated glucose values show a good correlation with the actual blood glucose concentrations. The portable device attached to the ear of a rat and measured the fluorescence intensity for three days. Therefore, our system shows the potential for practical, “true,” continuous glucose monitoring.