Ragda Mamoun, M. Hadi, Dr. Emtithal Ahmed, Dr. Omer Adam
{"title":"无创血糖连续监测系统的设计","authors":"Ragda Mamoun, M. Hadi, Dr. Emtithal Ahmed, Dr. Omer Adam","doi":"10.1109/ICCCEEE.2018.8515781","DOIUrl":null,"url":null,"abstract":"Conventional techniques for monitoring glucose levels are limited by tremendous side effects. Therefore, the noninvasive continuous glucose monitoring system was introduced to provide continuity of check, less side effects with an accuracy of 89%, by calculating the glucose level from the output voltage of the probe pulse oximeter through an equation derived using Microsoft Excel Regression Analysis Tool, allowing its display in a liquid crystal display and further regulation by injecting insulin or glucagon.","PeriodicalId":6567,"journal":{"name":"2018 International Conference on Computer, Control, Electrical, and Electronics Engineering (ICCCEEE)","volume":"60 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of Noninvasive Continuous Glucose Monitoring System\",\"authors\":\"Ragda Mamoun, M. Hadi, Dr. Emtithal Ahmed, Dr. Omer Adam\",\"doi\":\"10.1109/ICCCEEE.2018.8515781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Conventional techniques for monitoring glucose levels are limited by tremendous side effects. Therefore, the noninvasive continuous glucose monitoring system was introduced to provide continuity of check, less side effects with an accuracy of 89%, by calculating the glucose level from the output voltage of the probe pulse oximeter through an equation derived using Microsoft Excel Regression Analysis Tool, allowing its display in a liquid crystal display and further regulation by injecting insulin or glucagon.\",\"PeriodicalId\":6567,\"journal\":{\"name\":\"2018 International Conference on Computer, Control, Electrical, and Electronics Engineering (ICCCEEE)\",\"volume\":\"60 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Computer, Control, Electrical, and Electronics Engineering (ICCCEEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCCEEE.2018.8515781\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Computer, Control, Electrical, and Electronics Engineering (ICCCEEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCCEEE.2018.8515781","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design of Noninvasive Continuous Glucose Monitoring System
Conventional techniques for monitoring glucose levels are limited by tremendous side effects. Therefore, the noninvasive continuous glucose monitoring system was introduced to provide continuity of check, less side effects with an accuracy of 89%, by calculating the glucose level from the output voltage of the probe pulse oximeter through an equation derived using Microsoft Excel Regression Analysis Tool, allowing its display in a liquid crystal display and further regulation by injecting insulin or glucagon.