单区系统负载频率控制:实验方法:第1部分

Anoop Kumar Mohanta, Ritesh Dash, C. Behera, Priyabrata Behera
{"title":"单区系统负载频率控制:实验方法:第1部分","authors":"Anoop Kumar Mohanta, Ritesh Dash, C. Behera, Priyabrata Behera","doi":"10.1109/ICCPCT.2015.7159522","DOIUrl":null,"url":null,"abstract":"Transmission and distribution of power over the tie line depends upon the amount of load connected to it. As the entire power system is a completely non linear network so steady state analysis of the power system is a very difficult task. In order to maintain the system voltage and frequency with that of the change in the loads demand it is require to modify the system suitable controller. If the generation system is considering only one generation unit and one load area it can be treated as a one area network. So for one area network the system frequency can be controlled through the either P or PI controller. This paper tries to identifies the different types of problem occurring in the single area network with their behavior to active and reactive power system.","PeriodicalId":6650,"journal":{"name":"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Load frequency control of a single area system: An experimental approach: Part-1\",\"authors\":\"Anoop Kumar Mohanta, Ritesh Dash, C. Behera, Priyabrata Behera\",\"doi\":\"10.1109/ICCPCT.2015.7159522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transmission and distribution of power over the tie line depends upon the amount of load connected to it. As the entire power system is a completely non linear network so steady state analysis of the power system is a very difficult task. In order to maintain the system voltage and frequency with that of the change in the loads demand it is require to modify the system suitable controller. If the generation system is considering only one generation unit and one load area it can be treated as a one area network. So for one area network the system frequency can be controlled through the either P or PI controller. This paper tries to identifies the different types of problem occurring in the single area network with their behavior to active and reactive power system.\",\"PeriodicalId\":6650,\"journal\":{\"name\":\"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCPCT.2015.7159522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCPCT.2015.7159522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电力在联络线上的传输和分配取决于与之相连的负载量。由于整个电力系统是一个完全非线性的网络,因此电力系统的稳态分析是一项非常困难的任务。为了保持系统电压和频率随负载需求的变化而变化,需要对系统进行适当的控制器修改。如果发电系统只考虑一个发电机组和一个负荷区域,则可以将其视为一个单区网络。因此,对于一个局域网,系统频率可以通过P或PI控制器进行控制。本文试图识别单网中出现的不同类型的问题及其对有功和无功系统的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Load frequency control of a single area system: An experimental approach: Part-1
Transmission and distribution of power over the tie line depends upon the amount of load connected to it. As the entire power system is a completely non linear network so steady state analysis of the power system is a very difficult task. In order to maintain the system voltage and frequency with that of the change in the loads demand it is require to modify the system suitable controller. If the generation system is considering only one generation unit and one load area it can be treated as a one area network. So for one area network the system frequency can be controlled through the either P or PI controller. This paper tries to identifies the different types of problem occurring in the single area network with their behavior to active and reactive power system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Named entity recognition approaches: A study applied to English and Hindi language Design of asynchronous NoC using 3-port asynchronous T-routers Large-scale steganalysis using outlier detection method for image sharing application Neural network based SOM for multispectral image segmentation in RGB and HSV color space Kernel weighted FCM based MR image segmentation for brain tumor detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1