Giulio Giovannetti, Alessandra Flori, Daniele De Marchi, Giuseppe Matarazzo, Francesca Frijia, Silvia Burchielli, Domenico Montanaro, Giovanni Donato Aquaro, Luca Menichetti
{"title":"用于磁共振成像和光谱学的椭圆表面线圈的模拟、设计和测试","authors":"Giulio Giovannetti, Alessandra Flori, Daniele De Marchi, Giuseppe Matarazzo, Francesca Frijia, Silvia Burchielli, Domenico Montanaro, Giovanni Donato Aquaro, Luca Menichetti","doi":"10.1002/cmr.b.21361","DOIUrl":null,"url":null,"abstract":"<p>The simplest design of surface coils for magnetic resonance imaging (MRI) applications is circular and square loops, both producing a magnetic field perpendicular to the coil plane in the central region-of-interest (ROI), with an amplitude that decreases along the coil axis. However, a surface coil constituted by a loop with different geometry could be necessary when particular field-of-views (FOVs) are desired, especially for performing imaging in an elongated region. This can be achieved by using an elliptical loop, which can guarantee a wide longitudinal FOV and a good penetration in deep sample regions. This work proposes the application of a method for elliptical coil Signal-to-Noise Ratio (SNR) estimation previously developed for circular and square loop design, in which coil inductance and resistance are analytically calculated and the magnetic field pattern is estimated using the magnetostatic approach, while the sample-induced resistance is calculated with the vector potential calculation method. In the second part of the paper, we propose the simulation and the design of a transmit/receive elliptical coil for MRI in mice with a 3T clinical scanner. We also evaluated the coil performance in a preliminary magnetic resonance spectroscopy (MRS) study in phantom.</p>","PeriodicalId":50623,"journal":{"name":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","volume":"47B 4","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2018-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/cmr.b.21361","citationCount":"7","resultStr":"{\"title\":\"Simulation, design, and test of an elliptical surface coil for magnetic resonance imaging and spectroscopy\",\"authors\":\"Giulio Giovannetti, Alessandra Flori, Daniele De Marchi, Giuseppe Matarazzo, Francesca Frijia, Silvia Burchielli, Domenico Montanaro, Giovanni Donato Aquaro, Luca Menichetti\",\"doi\":\"10.1002/cmr.b.21361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The simplest design of surface coils for magnetic resonance imaging (MRI) applications is circular and square loops, both producing a magnetic field perpendicular to the coil plane in the central region-of-interest (ROI), with an amplitude that decreases along the coil axis. However, a surface coil constituted by a loop with different geometry could be necessary when particular field-of-views (FOVs) are desired, especially for performing imaging in an elongated region. This can be achieved by using an elliptical loop, which can guarantee a wide longitudinal FOV and a good penetration in deep sample regions. This work proposes the application of a method for elliptical coil Signal-to-Noise Ratio (SNR) estimation previously developed for circular and square loop design, in which coil inductance and resistance are analytically calculated and the magnetic field pattern is estimated using the magnetostatic approach, while the sample-induced resistance is calculated with the vector potential calculation method. In the second part of the paper, we propose the simulation and the design of a transmit/receive elliptical coil for MRI in mice with a 3T clinical scanner. We also evaluated the coil performance in a preliminary magnetic resonance spectroscopy (MRS) study in phantom.</p>\",\"PeriodicalId\":50623,\"journal\":{\"name\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"volume\":\"47B 4\",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2018-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/cmr.b.21361\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21361\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cmr.b.21361","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
Simulation, design, and test of an elliptical surface coil for magnetic resonance imaging and spectroscopy
The simplest design of surface coils for magnetic resonance imaging (MRI) applications is circular and square loops, both producing a magnetic field perpendicular to the coil plane in the central region-of-interest (ROI), with an amplitude that decreases along the coil axis. However, a surface coil constituted by a loop with different geometry could be necessary when particular field-of-views (FOVs) are desired, especially for performing imaging in an elongated region. This can be achieved by using an elliptical loop, which can guarantee a wide longitudinal FOV and a good penetration in deep sample regions. This work proposes the application of a method for elliptical coil Signal-to-Noise Ratio (SNR) estimation previously developed for circular and square loop design, in which coil inductance and resistance are analytically calculated and the magnetic field pattern is estimated using the magnetostatic approach, while the sample-induced resistance is calculated with the vector potential calculation method. In the second part of the paper, we propose the simulation and the design of a transmit/receive elliptical coil for MRI in mice with a 3T clinical scanner. We also evaluated the coil performance in a preliminary magnetic resonance spectroscopy (MRS) study in phantom.
期刊介绍:
Concepts in Magnetic Resonance Part B brings together engineers and physicists involved in the design and development of hardware and software employed in magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods.
Contributors come from both academia and industry, to report the latest advancements in the development of instrumentation and computer programming to underpin medical, non-medical, and analytical magnetic resonance techniques.