弥散MRI脉冲序列中b矩阵自动精确计算的一般框架

IF 0.9 4区 医学 Q4 CHEMISTRY, PHYSICAL Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering Pub Date : 2023-04-05 DOI:10.1155/2023/4610812
Lisha Yuan, Dan Wu, Hongjian He, Jianhui Zhong
{"title":"弥散MRI脉冲序列中b矩阵自动精确计算的一般框架","authors":"Lisha Yuan, Dan Wu, Hongjian He, Jianhui Zhong","doi":"10.1155/2023/4610812","DOIUrl":null,"url":null,"abstract":"To derive accurate diffusion metrics, both imaging and diffusion-sensitizing gradient pulses should be accounted for when calculating the diffusion-weighted b-matrix. However, it is complex to derive analytical solutions due to complicated interactions between gradient pulses, including orthogonal directions. This study proposes a general framework to calculate the b-matrix automatically (dubbed as Auto-b). Based on the divide-and-conquer approach, the b-matrix calculation is appropriately segmented, and the symbolic mathematical library is applied to handle integration operations for each interval. If the specifications of all gradient pulses are provided to Auto-b, an accurate b-matrix can be obtained. Three examples are explored to validate the accuracy of Auto-b and to detect b-value errors when using approximate calculations. (1) In the conventional spin-echo example, Auto-b exhibits high accuracy, as indicated by the maximum relative deviation of 1.68‰ between its calculated b-matrices and those obtained from analytical expressions. (2) Auto-b is applied to investigate the contribution of imaging gradients to the b-matrix in an optimized spin-echo echo planar imaging sequence at submillimeter resolution. Specifically, ignoring the contribution of imaging gradients results in a b-value error of 12.16 s/mm2 at the 0.8 × 0.8 × 0.8 mm3 resolution and 22.47 s/mm2 at the 0.6 × 0.6 × 0.8 mm3 resolution, respectively, when nominal b = 0. (3) Auto-b is also utilized to analyze the influence of approximate calculations in the spatiotemporally encoded sequence. The results showed that neglecting the contribution of phase-encoding blips causes large b-value errors up to 11.02 s/mm2. In addition, the rectangularization of trapezoidal waveforms led to a high relative b-value error of 39.91%. This study validates the high accuracy of Auto-b and underscores the importance of accurate b-value calculations in both submillimeter imaging and spatiotemporally encoded sequences. Attributed to its automation, accuracy, and broad applicability, Auto-b is helpful for developers of diffusion sequences.","PeriodicalId":50623,"journal":{"name":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","volume":"45 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2023-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences\",\"authors\":\"Lisha Yuan, Dan Wu, Hongjian He, Jianhui Zhong\",\"doi\":\"10.1155/2023/4610812\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To derive accurate diffusion metrics, both imaging and diffusion-sensitizing gradient pulses should be accounted for when calculating the diffusion-weighted b-matrix. However, it is complex to derive analytical solutions due to complicated interactions between gradient pulses, including orthogonal directions. This study proposes a general framework to calculate the b-matrix automatically (dubbed as Auto-b). Based on the divide-and-conquer approach, the b-matrix calculation is appropriately segmented, and the symbolic mathematical library is applied to handle integration operations for each interval. If the specifications of all gradient pulses are provided to Auto-b, an accurate b-matrix can be obtained. Three examples are explored to validate the accuracy of Auto-b and to detect b-value errors when using approximate calculations. (1) In the conventional spin-echo example, Auto-b exhibits high accuracy, as indicated by the maximum relative deviation of 1.68‰ between its calculated b-matrices and those obtained from analytical expressions. (2) Auto-b is applied to investigate the contribution of imaging gradients to the b-matrix in an optimized spin-echo echo planar imaging sequence at submillimeter resolution. Specifically, ignoring the contribution of imaging gradients results in a b-value error of 12.16 s/mm2 at the 0.8 × 0.8 × 0.8 mm3 resolution and 22.47 s/mm2 at the 0.6 × 0.6 × 0.8 mm3 resolution, respectively, when nominal b = 0. (3) Auto-b is also utilized to analyze the influence of approximate calculations in the spatiotemporally encoded sequence. The results showed that neglecting the contribution of phase-encoding blips causes large b-value errors up to 11.02 s/mm2. In addition, the rectangularization of trapezoidal waveforms led to a high relative b-value error of 39.91%. This study validates the high accuracy of Auto-b and underscores the importance of accurate b-value calculations in both submillimeter imaging and spatiotemporally encoded sequences. Attributed to its automation, accuracy, and broad applicability, Auto-b is helpful for developers of diffusion sequences.\",\"PeriodicalId\":50623,\"journal\":{\"name\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"volume\":\"45 1\",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2023/4610812\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part B-Magnetic Resonance Engineering","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2023/4610812","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

摘要

为了得到准确的扩散度量,在计算扩散加权b矩阵时,应考虑成像和扩散敏化梯度脉冲。然而,由于梯度脉冲之间复杂的相互作用,包括正交方向,推导解析解是复杂的。本研究提出一个自动计算b矩阵的一般框架(称为Auto-b)。在分治法的基础上,对b矩阵计算进行了适当的分割,并应用符号数学库对每个区间进行积分运算。如果将所有梯度脉冲的规格提供给Auto-b,则可以得到精确的b矩阵。探讨了三个例子来验证Auto-b的准确性,并在使用近似计算时检测b值误差。(1)在常规的自旋回波算例中,Auto-b具有较高的精度,其计算的b-矩阵与解析表达式的最大相对偏差为1.68‰。(2)应用Auto-b研究了优化的亚毫米分辨率自旋回波回波平面成像序列中成像梯度对b矩阵的贡献。具体来说,当标称b = 0时,忽略成像梯度的影响,在0.8 × 0.8 × 0.8 mm3分辨率下的b值误差为12.16 s/mm2,在0.6 × 0.6 × 0.8 mm3分辨率下的误差为22.47 s/mm2。(3) Auto-b还用于分析近似计算对时空编码序列的影响。结果表明,忽略相位编码小点的贡献会导致较大的b值误差,误差可达11.02 s/mm2。此外,梯形波形的矩形化导致相对b值误差高达39.91%。该研究验证了Auto-b的高精度,并强调了精确的b值计算在亚毫米成像和时空编码序列中的重要性。由于其自动化,准确性和广泛的适用性,Auto-b对扩散序列的开发人员很有帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences
To derive accurate diffusion metrics, both imaging and diffusion-sensitizing gradient pulses should be accounted for when calculating the diffusion-weighted b-matrix. However, it is complex to derive analytical solutions due to complicated interactions between gradient pulses, including orthogonal directions. This study proposes a general framework to calculate the b-matrix automatically (dubbed as Auto-b). Based on the divide-and-conquer approach, the b-matrix calculation is appropriately segmented, and the symbolic mathematical library is applied to handle integration operations for each interval. If the specifications of all gradient pulses are provided to Auto-b, an accurate b-matrix can be obtained. Three examples are explored to validate the accuracy of Auto-b and to detect b-value errors when using approximate calculations. (1) In the conventional spin-echo example, Auto-b exhibits high accuracy, as indicated by the maximum relative deviation of 1.68‰ between its calculated b-matrices and those obtained from analytical expressions. (2) Auto-b is applied to investigate the contribution of imaging gradients to the b-matrix in an optimized spin-echo echo planar imaging sequence at submillimeter resolution. Specifically, ignoring the contribution of imaging gradients results in a b-value error of 12.16 s/mm2 at the 0.8 × 0.8 × 0.8 mm3 resolution and 22.47 s/mm2 at the 0.6 × 0.6 × 0.8 mm3 resolution, respectively, when nominal b = 0. (3) Auto-b is also utilized to analyze the influence of approximate calculations in the spatiotemporally encoded sequence. The results showed that neglecting the contribution of phase-encoding blips causes large b-value errors up to 11.02 s/mm2. In addition, the rectangularization of trapezoidal waveforms led to a high relative b-value error of 39.91%. This study validates the high accuracy of Auto-b and underscores the importance of accurate b-value calculations in both submillimeter imaging and spatiotemporally encoded sequences. Attributed to its automation, accuracy, and broad applicability, Auto-b is helpful for developers of diffusion sequences.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
3
审稿时长
>12 weeks
期刊介绍: Concepts in Magnetic Resonance Part B brings together engineers and physicists involved in the design and development of hardware and software employed in magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods. Contributors come from both academia and industry, to report the latest advancements in the development of instrumentation and computer programming to underpin medical, non-medical, and analytical magnetic resonance techniques.
期刊最新文献
Impact of Patient Body Posture on RF-Induced Energy Absorption by Orthopedic Plates Odd-Leg Birdcages for Geometric Decoupling in Multinuclear Imaging and Spectroscopy A General Framework for Automated Accurate Calculation of b-Matrix (Auto-b) in Diffusion MRI Pulse Sequences Development of Electron Paramagnetic Resonance Magnet System for In Vivo Tooth Dosimetry Diagnosis of Alzheimer’s Disease with Extreme Learning Machine on Whole-Brain Functional Connectivity
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1