Junyi Li, Hong Wang, Huiying Wang, Z. Zhang, P. Cheng, G. Ding
{"title":"Cu-TSV单轴微拉伸试验独立试样的设计与制作","authors":"Junyi Li, Hong Wang, Huiying Wang, Z. Zhang, P. Cheng, G. Ding","doi":"10.1109/ISAPM.2011.6105725","DOIUrl":null,"url":null,"abstract":"A novel test sample with a micro scale free-standing specimen of Cu-TSV used for uniaxial micro-tensile test is presented in this paper. Design of a deformation-buffer reticular supporting frame of the test sample effectively reduces the deformation of Cu-TSV thin film during clamping operation. The stress resulting from electrodepositon process is minimized by fabricating Cu-TSV thin film on surface-treated titanium seed layer. The process of titanium seed layer avoids alkali corrosion and simplifies fabrication procedure compared with that of the traditional Cr/Cu seed layer. Both finite-element method (FEM) simulation and experimental results indicates the advantages of this new design. The test sample fabricated by the optimized process well coordinates with our micro-tensile system. The Young's modulus and the ultimate tensile strength of tested Cu-TSV thin film measured by our micro-tensile system are 25.4∼32.9GPa and 574∼764MPa, respectively.","PeriodicalId":6440,"journal":{"name":"2011 International Symposium on Advanced Packaging Materials (APM)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Design and fabrication of Cu-TSV free-standing specimen for uniaxial micro-tensile test\",\"authors\":\"Junyi Li, Hong Wang, Huiying Wang, Z. Zhang, P. Cheng, G. Ding\",\"doi\":\"10.1109/ISAPM.2011.6105725\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel test sample with a micro scale free-standing specimen of Cu-TSV used for uniaxial micro-tensile test is presented in this paper. Design of a deformation-buffer reticular supporting frame of the test sample effectively reduces the deformation of Cu-TSV thin film during clamping operation. The stress resulting from electrodepositon process is minimized by fabricating Cu-TSV thin film on surface-treated titanium seed layer. The process of titanium seed layer avoids alkali corrosion and simplifies fabrication procedure compared with that of the traditional Cr/Cu seed layer. Both finite-element method (FEM) simulation and experimental results indicates the advantages of this new design. The test sample fabricated by the optimized process well coordinates with our micro-tensile system. The Young's modulus and the ultimate tensile strength of tested Cu-TSV thin film measured by our micro-tensile system are 25.4∼32.9GPa and 574∼764MPa, respectively.\",\"PeriodicalId\":6440,\"journal\":{\"name\":\"2011 International Symposium on Advanced Packaging Materials (APM)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Symposium on Advanced Packaging Materials (APM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISAPM.2011.6105725\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Symposium on Advanced Packaging Materials (APM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAPM.2011.6105725","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and fabrication of Cu-TSV free-standing specimen for uniaxial micro-tensile test
A novel test sample with a micro scale free-standing specimen of Cu-TSV used for uniaxial micro-tensile test is presented in this paper. Design of a deformation-buffer reticular supporting frame of the test sample effectively reduces the deformation of Cu-TSV thin film during clamping operation. The stress resulting from electrodepositon process is minimized by fabricating Cu-TSV thin film on surface-treated titanium seed layer. The process of titanium seed layer avoids alkali corrosion and simplifies fabrication procedure compared with that of the traditional Cr/Cu seed layer. Both finite-element method (FEM) simulation and experimental results indicates the advantages of this new design. The test sample fabricated by the optimized process well coordinates with our micro-tensile system. The Young's modulus and the ultimate tensile strength of tested Cu-TSV thin film measured by our micro-tensile system are 25.4∼32.9GPa and 574∼764MPa, respectively.