利用RELAP5对RSG-GAS研究堆进行热水力基准测试

E. P. Hastuti, A. S. Ekariansyah, Sudarmono, Sujarwono, S. Wetchagarun
{"title":"利用RELAP5对RSG-GAS研究堆进行热水力基准测试","authors":"E. P. Hastuti, A. S. Ekariansyah, Sudarmono, Sujarwono, S. Wetchagarun","doi":"10.1063/1.5135534","DOIUrl":null,"url":null,"abstract":"RSG-GAS multipurpose reactor was designed to be able to operate with 30 MW power. In order to obtain operation license renewal from Indonesia Nuclear Regulatory Body-BAPETEN, it is required that evaluation or assessment on any systems related RSG-GAS full power operation should be performed. This research has two objectives. The first is to re-evaluate overall RSG-GAS system capability, the second objective is to benchmark RELAP5 model for RSG-GAS based on the input obtained from the experiment results. The results of the experiment on the raising of RSG-GAS power to its full power of 30 MW and power calibration by calorimetric indicate that there is a significant difference between definitive power and measured power, caused by the determination of correction factor. The RELAP5 modeling for RSG-GAS using experimental data input indicates a deviation of 1.77 % to 8.73 % for temperature calculation, while the deviation is 5.6% - 7.66% for flow rate. These figures indicate that this modeling for RSG-GAS is valid. The highest fuel temperature at steady state condition at 30 MW is 87.12°C. The highest temperature limit at the beginning of the cycle is 175°C, which is still in the permitted envelope. It was shown that RSG-GAS could operate at its full power of 30 MW. Key words: RSG-GAS, RELAP5, periodic safety review, benchmarking, thermal-hydraulic","PeriodicalId":22239,"journal":{"name":"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019","volume":"4 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Thermal-hydraulic benchmarking of RSG-GAS research reactor using RELAP5\",\"authors\":\"E. P. Hastuti, A. S. Ekariansyah, Sudarmono, Sujarwono, S. Wetchagarun\",\"doi\":\"10.1063/1.5135534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"RSG-GAS multipurpose reactor was designed to be able to operate with 30 MW power. In order to obtain operation license renewal from Indonesia Nuclear Regulatory Body-BAPETEN, it is required that evaluation or assessment on any systems related RSG-GAS full power operation should be performed. This research has two objectives. The first is to re-evaluate overall RSG-GAS system capability, the second objective is to benchmark RELAP5 model for RSG-GAS based on the input obtained from the experiment results. The results of the experiment on the raising of RSG-GAS power to its full power of 30 MW and power calibration by calorimetric indicate that there is a significant difference between definitive power and measured power, caused by the determination of correction factor. The RELAP5 modeling for RSG-GAS using experimental data input indicates a deviation of 1.77 % to 8.73 % for temperature calculation, while the deviation is 5.6% - 7.66% for flow rate. These figures indicate that this modeling for RSG-GAS is valid. The highest fuel temperature at steady state condition at 30 MW is 87.12°C. The highest temperature limit at the beginning of the cycle is 175°C, which is still in the permitted envelope. It was shown that RSG-GAS could operate at its full power of 30 MW. Key words: RSG-GAS, RELAP5, periodic safety review, benchmarking, thermal-hydraulic\",\"PeriodicalId\":22239,\"journal\":{\"name\":\"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.5135534\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE 4TH BIOMEDICAL ENGINEERING’S RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, HEALTH, AND MEDICAL DEVICES: Proceedings of the International Symposium of Biomedical Engineering (ISBE) 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.5135534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

RSG-GAS多用途反应堆的设计功率为30兆瓦。为了获得印尼核监管机构bapeten的运行许可证更新,需要对任何与RSG-GAS全功率运行相关的系统进行评估或评估。这项研究有两个目的。第一个目标是重新评估RSG-GAS系统的整体能力,第二个目标是根据从实验结果中获得的输入对RSG-GAS的RELAP5模型进行基准测试。将RSG-GAS功率提高到最大功率30mw并进行量热法功率校准的实验结果表明,校正系数的确定导致定标功率与实测功率存在显著差异。利用实验数据输入对RSG-GAS进行RELAP5建模,温度计算偏差为1.77% ~ 8.73%,流量计算偏差为5.6% ~ 7.66%。这些数据表明,RSG-GAS模型是有效的。30 MW稳态条件下的最高燃料温度为87.12℃。循环开始时的最高温度限制为175°C,仍在允许的范围内。结果表明,RSG-GAS可以在30mw的全功率下运行。关键词:RSG-GAS, RELAP5,定期安全评审,对标,热液
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Thermal-hydraulic benchmarking of RSG-GAS research reactor using RELAP5
RSG-GAS multipurpose reactor was designed to be able to operate with 30 MW power. In order to obtain operation license renewal from Indonesia Nuclear Regulatory Body-BAPETEN, it is required that evaluation or assessment on any systems related RSG-GAS full power operation should be performed. This research has two objectives. The first is to re-evaluate overall RSG-GAS system capability, the second objective is to benchmark RELAP5 model for RSG-GAS based on the input obtained from the experiment results. The results of the experiment on the raising of RSG-GAS power to its full power of 30 MW and power calibration by calorimetric indicate that there is a significant difference between definitive power and measured power, caused by the determination of correction factor. The RELAP5 modeling for RSG-GAS using experimental data input indicates a deviation of 1.77 % to 8.73 % for temperature calculation, while the deviation is 5.6% - 7.66% for flow rate. These figures indicate that this modeling for RSG-GAS is valid. The highest fuel temperature at steady state condition at 30 MW is 87.12°C. The highest temperature limit at the beginning of the cycle is 175°C, which is still in the permitted envelope. It was shown that RSG-GAS could operate at its full power of 30 MW. Key words: RSG-GAS, RELAP5, periodic safety review, benchmarking, thermal-hydraulic
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of tools utilization monitoring system on labor-intensive manufacturing industries Topology optimization on geometry of 3D printed “Impulse RC Alien 4 Inch” racing quadcopter frame with polylactic acid material Design and analysis of regenerative shock absorber using ball screw mechanism for vehicle suspension Effect of Sundanese music on daytime sleep quality based on EEG signal Static analysis of an energy storage and return (ESAR) prosthetic foot
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1