{"title":"采用双隔离中性点的非对称六相感应电动机提高可靠性","authors":"Elhussien A. Mahmoud","doi":"10.2118/193151-MS","DOIUrl":null,"url":null,"abstract":"\n This work suggested the use of asymmetrical six phase induction motors instead of the conventional three phase motors for safety critical equipment to improve the overall system reliability. The rule of thumb is that a single fault should not be able to draw safety critical equipment out of service. Multi-phase machine in general and six phase machine in particular are able to continue running with one phase or more open circuit. The ability of multi-phase machines even to start under fault is another useful feature. Statistically, the main reason for losing one of the motor phases is the single open gate transistor fault. The defected phase is entirely disregarded, and then the current in the rest of phases which still functioning is optimized. Consequently, if minimum copper loss criterion is applied, the paid penalty is 50% additional losses that leads to motor derating, if not pre-designed with proper safety factor. This paper introduces an alternative post fault control strategy, which allows the usage of the entire healthy power electronic switches. An achievement of reducing the post fault increase in stator copper losses to 25% is realized.","PeriodicalId":11014,"journal":{"name":"Day 1 Mon, November 12, 2018","volume":"50 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Increased Reliability Using Asymmetrical Six Phase Induction Motor with Double Isolated Neutral\",\"authors\":\"Elhussien A. Mahmoud\",\"doi\":\"10.2118/193151-MS\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n This work suggested the use of asymmetrical six phase induction motors instead of the conventional three phase motors for safety critical equipment to improve the overall system reliability. The rule of thumb is that a single fault should not be able to draw safety critical equipment out of service. Multi-phase machine in general and six phase machine in particular are able to continue running with one phase or more open circuit. The ability of multi-phase machines even to start under fault is another useful feature. Statistically, the main reason for losing one of the motor phases is the single open gate transistor fault. The defected phase is entirely disregarded, and then the current in the rest of phases which still functioning is optimized. Consequently, if minimum copper loss criterion is applied, the paid penalty is 50% additional losses that leads to motor derating, if not pre-designed with proper safety factor. This paper introduces an alternative post fault control strategy, which allows the usage of the entire healthy power electronic switches. An achievement of reducing the post fault increase in stator copper losses to 25% is realized.\",\"PeriodicalId\":11014,\"journal\":{\"name\":\"Day 1 Mon, November 12, 2018\",\"volume\":\"50 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 1 Mon, November 12, 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/193151-MS\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, November 12, 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/193151-MS","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

这项工作建议在安全关键设备中使用非对称六相感应电机来代替传统的三相电机,以提高整个系统的可靠性。经验法则是,单个故障不应该能够使安全关键设备停止服务。多相电机,特别是六相电机,一般都能在一相或多相开路情况下继续运行。多相电机甚至在故障情况下启动的能力是另一个有用的特性。据统计,电动机失相的主要原因是单开栅晶体管故障。完全忽略有缺陷的相位,然后优化仍在工作的其余相位中的电流。因此,如果采用最小铜损耗标准,如果没有预先设计适当的安全系数,则支付的罚款是导致电机降额的50%额外损耗。本文介绍了一种可选择的故障后控制策略,该策略允许使用整个健康的电力电子开关。实现了将后故障后定子铜损增量降低到25%的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Increased Reliability Using Asymmetrical Six Phase Induction Motor with Double Isolated Neutral
This work suggested the use of asymmetrical six phase induction motors instead of the conventional three phase motors for safety critical equipment to improve the overall system reliability. The rule of thumb is that a single fault should not be able to draw safety critical equipment out of service. Multi-phase machine in general and six phase machine in particular are able to continue running with one phase or more open circuit. The ability of multi-phase machines even to start under fault is another useful feature. Statistically, the main reason for losing one of the motor phases is the single open gate transistor fault. The defected phase is entirely disregarded, and then the current in the rest of phases which still functioning is optimized. Consequently, if minimum copper loss criterion is applied, the paid penalty is 50% additional losses that leads to motor derating, if not pre-designed with proper safety factor. This paper introduces an alternative post fault control strategy, which allows the usage of the entire healthy power electronic switches. An achievement of reducing the post fault increase in stator copper losses to 25% is realized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Does the kappa number method accurately reflect lignin content in nonwood pulps? Using multistage models to evaluate how pulp washing after the first extraction stage impacts elemental chlorine-free bleach demand Understanding the risks and rewards of using 50% vs. 10% strength peroxide in pulp bleach plants Understanding the pulping and bleaching performances of eucalyptus woods affected by physiological disturbance Measurements of the Inorganic Scale Buildup Rate on Downhole Completion Equipment – Debris Barrier Screens
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1