{"title":"使用“VEB-1”和“VEB-2”装置进行电刺激会导致气体放电可视化参数几乎相同的变化","authors":"N. Babelyuk","doi":"10.25040/ecpb2020.02.005","DOIUrl":null,"url":null,"abstract":"Introduction . In 2015, a generator for electrotherapy and stimulation oh human nerve centers was created, called “VEB-1”. Preliminary observation of volunteers revealed a modulating effect of a four-day course of electrical stimulation on the parameters of electroencephalogram, metabolism, as well as gas-discharge visualization (GDV). Recently designed device \"VEB-2\". This report launches a series of articles on a comparative study of the course effects of the devices \"VEB-1\" and \"VEB-2\" on the human body. GDV was chosen as the first method. Material and research methods. The object of observation were 18 volunteers: 11 women aged 29-62 years (Mean±SD: 51±12) without clinical diagnose but with dysfunction of neuro-endocrine-immune complex and metabolism. In the morning registered kirlianogram by the method of GDV by the device of “GDV Chamber”. After the initial testing, an electrical stimulation session was performed with a VEB-1 or a VEB-2 devices/ The next morning after completing the four-day course, retesting was performed. The reference values of the parameters are taken from the database of our laboratory. the following [17], then the price change of the latter parameters will wait. The effects on the set of GDV parameters are almost equally pronounced in people of both sexes when using both devices. Conclusion. The use of an additional electrode for direct impact on individual organs in the device \"VEB-2\" is excessive, it is enough to affect only the nerve plexuses.","PeriodicalId":12101,"journal":{"name":"Experimental and Clinical Physiology and Biochemistry","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Electrostimulation with the devices «VEB-1» and «VEB-2» causes almost identical changes in the parameters of gas-discharge visualization\",\"authors\":\"N. Babelyuk\",\"doi\":\"10.25040/ecpb2020.02.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction . In 2015, a generator for electrotherapy and stimulation oh human nerve centers was created, called “VEB-1”. Preliminary observation of volunteers revealed a modulating effect of a four-day course of electrical stimulation on the parameters of electroencephalogram, metabolism, as well as gas-discharge visualization (GDV). Recently designed device \\\"VEB-2\\\". This report launches a series of articles on a comparative study of the course effects of the devices \\\"VEB-1\\\" and \\\"VEB-2\\\" on the human body. GDV was chosen as the first method. Material and research methods. The object of observation were 18 volunteers: 11 women aged 29-62 years (Mean±SD: 51±12) without clinical diagnose but with dysfunction of neuro-endocrine-immune complex and metabolism. In the morning registered kirlianogram by the method of GDV by the device of “GDV Chamber”. After the initial testing, an electrical stimulation session was performed with a VEB-1 or a VEB-2 devices/ The next morning after completing the four-day course, retesting was performed. The reference values of the parameters are taken from the database of our laboratory. the following [17], then the price change of the latter parameters will wait. The effects on the set of GDV parameters are almost equally pronounced in people of both sexes when using both devices. Conclusion. The use of an additional electrode for direct impact on individual organs in the device \\\"VEB-2\\\" is excessive, it is enough to affect only the nerve plexuses.\",\"PeriodicalId\":12101,\"journal\":{\"name\":\"Experimental and Clinical Physiology and Biochemistry\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Experimental and Clinical Physiology and Biochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25040/ecpb2020.02.005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental and Clinical Physiology and Biochemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25040/ecpb2020.02.005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electrostimulation with the devices «VEB-1» and «VEB-2» causes almost identical changes in the parameters of gas-discharge visualization
Introduction . In 2015, a generator for electrotherapy and stimulation oh human nerve centers was created, called “VEB-1”. Preliminary observation of volunteers revealed a modulating effect of a four-day course of electrical stimulation on the parameters of electroencephalogram, metabolism, as well as gas-discharge visualization (GDV). Recently designed device "VEB-2". This report launches a series of articles on a comparative study of the course effects of the devices "VEB-1" and "VEB-2" on the human body. GDV was chosen as the first method. Material and research methods. The object of observation were 18 volunteers: 11 women aged 29-62 years (Mean±SD: 51±12) without clinical diagnose but with dysfunction of neuro-endocrine-immune complex and metabolism. In the morning registered kirlianogram by the method of GDV by the device of “GDV Chamber”. After the initial testing, an electrical stimulation session was performed with a VEB-1 or a VEB-2 devices/ The next morning after completing the four-day course, retesting was performed. The reference values of the parameters are taken from the database of our laboratory. the following [17], then the price change of the latter parameters will wait. The effects on the set of GDV parameters are almost equally pronounced in people of both sexes when using both devices. Conclusion. The use of an additional electrode for direct impact on individual organs in the device "VEB-2" is excessive, it is enough to affect only the nerve plexuses.