{"title":"双芯电力变压器:频率响应分析","authors":"C. Rojas, Sigridt García Martínez","doi":"10.35830/CN.VI82.543","DOIUrl":null,"url":null,"abstract":"The Frequency Response Analysis (FRA), is an excellent tool for the diagnosis and detection of internal faults in a transformer, such as: a displacement and winding deformation due to electromagnetic forces as a result of fault currents, the loosening of winding supports as a consequence of electric shocks or when the transformer is transported. These type of faults are mainly involved with the change in the geometry of the transfomer as a whole, a factor that alters the RLC parameters which represent the transformer, and therefore, its resonance points. The standard behavior of the three-phase three limbs transformer can be found in the literature. In this work, an analysis of the tests, which were applied in a double core transformer that is commoly used in arc furnaces, was carried out. The main feature of these transformers is that they feed high currents over a wide range of voltages.","PeriodicalId":100317,"journal":{"name":"Computer Networks and ISDN Systems","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Transformadores de Potencia con Doble Núcleo: Análisis de respuesta a la frecuencia\",\"authors\":\"C. Rojas, Sigridt García Martínez\",\"doi\":\"10.35830/CN.VI82.543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Frequency Response Analysis (FRA), is an excellent tool for the diagnosis and detection of internal faults in a transformer, such as: a displacement and winding deformation due to electromagnetic forces as a result of fault currents, the loosening of winding supports as a consequence of electric shocks or when the transformer is transported. These type of faults are mainly involved with the change in the geometry of the transfomer as a whole, a factor that alters the RLC parameters which represent the transformer, and therefore, its resonance points. The standard behavior of the three-phase three limbs transformer can be found in the literature. In this work, an analysis of the tests, which were applied in a double core transformer that is commoly used in arc furnaces, was carried out. The main feature of these transformers is that they feed high currents over a wide range of voltages.\",\"PeriodicalId\":100317,\"journal\":{\"name\":\"Computer Networks and ISDN Systems\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Networks and ISDN Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35830/CN.VI82.543\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Networks and ISDN Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35830/CN.VI82.543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transformadores de Potencia con Doble Núcleo: Análisis de respuesta a la frecuencia
The Frequency Response Analysis (FRA), is an excellent tool for the diagnosis and detection of internal faults in a transformer, such as: a displacement and winding deformation due to electromagnetic forces as a result of fault currents, the loosening of winding supports as a consequence of electric shocks or when the transformer is transported. These type of faults are mainly involved with the change in the geometry of the transfomer as a whole, a factor that alters the RLC parameters which represent the transformer, and therefore, its resonance points. The standard behavior of the three-phase three limbs transformer can be found in the literature. In this work, an analysis of the tests, which were applied in a double core transformer that is commoly used in arc furnaces, was carried out. The main feature of these transformers is that they feed high currents over a wide range of voltages.