{"title":"新型蒸汽室的性能测试","authors":"K. Hsieh, S. Wong","doi":"10.1109/IMPACT.2009.5382249","DOIUrl":null,"url":null,"abstract":"The performance of a novel vapor chamber is tested in this study. In this vapor chamber, parallel grooves are made on the inner surface of the top plate, with inter-groove openings, to replace the conventional porous wick. To the inner surface of the bottom plate is sintered a layer of porous wick as the evaporator. The peaks of the groove walls directly contact with the wick so that the grooves function as vapor path, condenser and structural supporters simultaneously. The corrugated groove walls provide not only an enlarged condensation area, but also a direct shortcut for a portion of the liquid condensed on the groove surface to be absorbed back to the wick. Thus, smaller liquid-flow resistance and hence high anti-dryout capability are achieved. The test module includes a copper plate-fin heat sink in combination with a top fan. In this study, the evaporator wick was made of sintered multi-layer copper screens and the footprint of the vapor chamber was 10 cm × 8.9 cm. With a 2.1 cm × 2.1 cm or a 1.1 cm × 1.1 cm heating area, the vapor chamber resistances were measured for heat load increasing from 80 W to beyond 300 W. Good performances with low vapor chamber resistance and large heat load limit were obtained under different orientations.","PeriodicalId":6410,"journal":{"name":"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference","volume":"44 1","pages":"573-576"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"62","resultStr":"{\"title\":\"Performance tests on a novel vapor chamber\",\"authors\":\"K. Hsieh, S. Wong\",\"doi\":\"10.1109/IMPACT.2009.5382249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of a novel vapor chamber is tested in this study. In this vapor chamber, parallel grooves are made on the inner surface of the top plate, with inter-groove openings, to replace the conventional porous wick. To the inner surface of the bottom plate is sintered a layer of porous wick as the evaporator. The peaks of the groove walls directly contact with the wick so that the grooves function as vapor path, condenser and structural supporters simultaneously. The corrugated groove walls provide not only an enlarged condensation area, but also a direct shortcut for a portion of the liquid condensed on the groove surface to be absorbed back to the wick. Thus, smaller liquid-flow resistance and hence high anti-dryout capability are achieved. The test module includes a copper plate-fin heat sink in combination with a top fan. In this study, the evaporator wick was made of sintered multi-layer copper screens and the footprint of the vapor chamber was 10 cm × 8.9 cm. With a 2.1 cm × 2.1 cm or a 1.1 cm × 1.1 cm heating area, the vapor chamber resistances were measured for heat load increasing from 80 W to beyond 300 W. Good performances with low vapor chamber resistance and large heat load limit were obtained under different orientations.\",\"PeriodicalId\":6410,\"journal\":{\"name\":\"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference\",\"volume\":\"44 1\",\"pages\":\"573-576\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"62\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMPACT.2009.5382249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 4th International Microsystems, Packaging, Assembly and Circuits Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMPACT.2009.5382249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 62

摘要

本文对一种新型蒸汽室进行了性能测试。在该蒸汽室中,在顶板的内表面上制作平行凹槽,凹槽间有开口,以取代传统的多孔灯芯。在底板的内表面烧结一层多孔灯芯作为蒸发器。槽壁的峰值与芯直接接触,使槽同时起蒸汽通道、冷凝器和结构支撑的作用。波纹槽壁不仅提供了一个扩大的冷凝面积,而且还提供了一个直接的捷径,使在槽表面冷凝的一部分液体被吸收回芯。因此,液体流动阻力较小,因此具有较高的抗干性。测试模块包括一个铜板翅散热器和一个顶部风扇。在本研究中,蒸发器芯芯由烧结多层铜网制成,蒸汽室占地面积为10 cm × 8.9 cm。在2.1 cm × 2.1 cm或1.1 cm × 1.1 cm的加热区域,测量了热负荷从80w增加到300w以上时的蒸汽室阻力。在不同取向下均获得了较低的气室阻力和较大的热负荷极限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Performance tests on a novel vapor chamber
The performance of a novel vapor chamber is tested in this study. In this vapor chamber, parallel grooves are made on the inner surface of the top plate, with inter-groove openings, to replace the conventional porous wick. To the inner surface of the bottom plate is sintered a layer of porous wick as the evaporator. The peaks of the groove walls directly contact with the wick so that the grooves function as vapor path, condenser and structural supporters simultaneously. The corrugated groove walls provide not only an enlarged condensation area, but also a direct shortcut for a portion of the liquid condensed on the groove surface to be absorbed back to the wick. Thus, smaller liquid-flow resistance and hence high anti-dryout capability are achieved. The test module includes a copper plate-fin heat sink in combination with a top fan. In this study, the evaporator wick was made of sintered multi-layer copper screens and the footprint of the vapor chamber was 10 cm × 8.9 cm. With a 2.1 cm × 2.1 cm or a 1.1 cm × 1.1 cm heating area, the vapor chamber resistances were measured for heat load increasing from 80 W to beyond 300 W. Good performances with low vapor chamber resistance and large heat load limit were obtained under different orientations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Estimation design of MEMS-based inertial navigation systems with noise coupling input saturation: Robust approach Experimental investigation and finite element analysis of bump wafer probing Optimum design of contact springs used in registered jack connectors Optimization design of cup-shaped copper heat spreaders for high-power InGaN/sapphire LEDs The high performance electrodeposited copper foil for next generation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1