压阻膜式表面应力传感器阵列布置,通过呼吸分析诊断癌症

F. Loizeau, Hans Peter Lang, Terunobu Akiyama, S. Gautsch, P. Vettiger, A. Tonin, Genki Yoshikawa, C. Gerber, N. D. Rooij
{"title":"压阻膜式表面应力传感器阵列布置,通过呼吸分析诊断癌症","authors":"F. Loizeau, Hans Peter Lang, Terunobu Akiyama, S. Gautsch, P. Vettiger, A. Tonin, Genki Yoshikawa, C. Gerber, N. D. Rooij","doi":"10.1109/MEMSYS.2013.6474318","DOIUrl":null,"url":null,"abstract":"We present the fabrication, characterization and successful medical application of a membrane-type surface stress sensor (MSS), arranged in arrays for molecular detection in gaseous phase. Made out of SOI substrate, a round membrane with a diameter of 500 μm and a thickness of 2.5 μm is suspended by four sensing beams with integrated p-type piezoresistors, composing a full Wheatstone bridge. The membrane is coated with a thin polymer layer, which reacts with volatile molecules and produces a deflection of the membrane. The membranes were functionalized with various polymers and characterized as humidity sensors with a sensitivity of 87 mV/%RH and a time constant (Tau63%) of 1.3 s. Finally, through breath analysis and the use of principal component analysis (PCA), we were able, in a double blind trial, to distinguish cancer patients and healthy persons.","PeriodicalId":92162,"journal":{"name":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Piezoresistive membrane-type surface stress sensor arranged in arrays for cancer diagnosis through breath analysis\",\"authors\":\"F. Loizeau, Hans Peter Lang, Terunobu Akiyama, S. Gautsch, P. Vettiger, A. Tonin, Genki Yoshikawa, C. Gerber, N. D. Rooij\",\"doi\":\"10.1109/MEMSYS.2013.6474318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present the fabrication, characterization and successful medical application of a membrane-type surface stress sensor (MSS), arranged in arrays for molecular detection in gaseous phase. Made out of SOI substrate, a round membrane with a diameter of 500 μm and a thickness of 2.5 μm is suspended by four sensing beams with integrated p-type piezoresistors, composing a full Wheatstone bridge. The membrane is coated with a thin polymer layer, which reacts with volatile molecules and produces a deflection of the membrane. The membranes were functionalized with various polymers and characterized as humidity sensors with a sensitivity of 87 mV/%RH and a time constant (Tau63%) of 1.3 s. Finally, through breath analysis and the use of principal component analysis (PCA), we were able, in a double blind trial, to distinguish cancer patients and healthy persons.\",\"PeriodicalId\":92162,\"journal\":{\"name\":\"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MEMSYS.2013.6474318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS 2013) : Taipei, Taiwan, 20-24 January 2013. IEEE International Conference on Micro Electro Mechanical Systems (26th : 2013 : Taipei, Taiwan)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MEMSYS.2013.6474318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

我们介绍了一种膜型表面应力传感器(MSS)的制造,表征和成功的医学应用,该传感器排列在阵列中用于气相分子检测。由SOI衬底制成直径为500 μm,厚度为2.5 μm的圆形薄膜,由四个集成p型压敏电阻的传感梁悬挂,构成一个完整的惠斯通电桥。膜上涂有一层薄薄的聚合物层,该聚合物层与挥发性分子反应并产生膜的偏转。该膜被各种聚合物功能化,具有87 mV/%RH的灵敏度和1.3 s的时间常数(Tau63%)的湿度传感器特性。最后,通过呼吸分析和主成分分析(PCA)的使用,我们能够在双盲试验中区分癌症患者和健康人。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Piezoresistive membrane-type surface stress sensor arranged in arrays for cancer diagnosis through breath analysis
We present the fabrication, characterization and successful medical application of a membrane-type surface stress sensor (MSS), arranged in arrays for molecular detection in gaseous phase. Made out of SOI substrate, a round membrane with a diameter of 500 μm and a thickness of 2.5 μm is suspended by four sensing beams with integrated p-type piezoresistors, composing a full Wheatstone bridge. The membrane is coated with a thin polymer layer, which reacts with volatile molecules and produces a deflection of the membrane. The membranes were functionalized with various polymers and characterized as humidity sensors with a sensitivity of 87 mV/%RH and a time constant (Tau63%) of 1.3 s. Finally, through breath analysis and the use of principal component analysis (PCA), we were able, in a double blind trial, to distinguish cancer patients and healthy persons.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Characterization of solid UV cross-linked PEGDA for biological applications Neurospheroid array on a flexible substrate for cortical microstimulation Simultaneous ablation and injection by electrically-induced mono-dispersed bubble knife for biomedical applications High power lithium ion microbatteries with lithographically defined 3-D porous electrodes Silicon nanowire and cantilever electromechanical switches with integrated piezoresistive transducers
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1