一自由度线性中风卧床康复机器人的可行性研究

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2021-09-01 DOI:10.1115/1.4050454
N. Berezny, D. Dowlatshahi, M. Ahmadi
{"title":"一自由度线性中风卧床康复机器人的可行性研究","authors":"N. Berezny, D. Dowlatshahi, M. Ahmadi","doi":"10.1115/1.4050454","DOIUrl":null,"url":null,"abstract":"\n A 1DOF lower limb rehabilitation robot is presented for delivering leg extension therapy to bed-bound stroke patients. Such a compact and minimal system may be beneficial in terms of compatibility with pre-existing hospital equipment, ease-of-use, safety, and cost. A set of design criteria was created based on the literature and on previous field work at a local hospital. The device uses admittance control to apply assistive or resistive forces, and can also use haptic feedback to increase user engagement. A pilot study on six healthy participants was used to determine the feasibility of such a minimal system in administering assistance or resistance through the leg extension exercise. Results indicate that a single DOF is capable of decreasing trajectory error with assistance and increasing user effort with resistance. Observations confirm that the minimal system is effective; however, extending the robot with additional DOFs so that it can target multiple bed-bound exercises may help to increase therapy duration.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":"126 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Feasibility of a One Degree-of-Freedom Linear Robot for Bed-Bound Stroke Rehabilitation\",\"authors\":\"N. Berezny, D. Dowlatshahi, M. Ahmadi\",\"doi\":\"10.1115/1.4050454\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n A 1DOF lower limb rehabilitation robot is presented for delivering leg extension therapy to bed-bound stroke patients. Such a compact and minimal system may be beneficial in terms of compatibility with pre-existing hospital equipment, ease-of-use, safety, and cost. A set of design criteria was created based on the literature and on previous field work at a local hospital. The device uses admittance control to apply assistive or resistive forces, and can also use haptic feedback to increase user engagement. A pilot study on six healthy participants was used to determine the feasibility of such a minimal system in administering assistance or resistance through the leg extension exercise. Results indicate that a single DOF is capable of decreasing trajectory error with assistance and increasing user effort with resistance. Observations confirm that the minimal system is effective; however, extending the robot with additional DOFs so that it can target multiple bed-bound exercises may help to increase therapy duration.\",\"PeriodicalId\":49305,\"journal\":{\"name\":\"Journal of Medical Devices-Transactions of the Asme\",\"volume\":\"126 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Devices-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4050454\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4050454","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种为卧床中风患者提供腿部伸展治疗的1DOF下肢康复机器人。这样一个紧凑和最小的系统在与现有医院设备的兼容性、易用性、安全性和成本方面可能是有益的。根据文献和以前在当地医院的实地工作,创建了一套设计标准。该设备使用导纳控制来施加辅助或阻力,也可以使用触觉反馈来增加用户参与度。对六名健康参与者进行了试点研究,以确定这种最小系统通过腿部伸展运动给予辅助或阻力的可行性。结果表明,单自由度在辅助的情况下可以减小轨迹误差,在阻力的情况下可以增加操作难度。观测证实最小系统是有效的;然而,给机器人增加额外的自由度,这样它就可以针对多次卧床锻炼,这可能有助于延长治疗时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of a One Degree-of-Freedom Linear Robot for Bed-Bound Stroke Rehabilitation
A 1DOF lower limb rehabilitation robot is presented for delivering leg extension therapy to bed-bound stroke patients. Such a compact and minimal system may be beneficial in terms of compatibility with pre-existing hospital equipment, ease-of-use, safety, and cost. A set of design criteria was created based on the literature and on previous field work at a local hospital. The device uses admittance control to apply assistive or resistive forces, and can also use haptic feedback to increase user engagement. A pilot study on six healthy participants was used to determine the feasibility of such a minimal system in administering assistance or resistance through the leg extension exercise. Results indicate that a single DOF is capable of decreasing trajectory error with assistance and increasing user effort with resistance. Observations confirm that the minimal system is effective; however, extending the robot with additional DOFs so that it can target multiple bed-bound exercises may help to increase therapy duration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
Mechanical Viability and Functionality Assessment of a New Sutureless Endoluminal Microvascular Device: A Preliminary In Vivo Rabbit Study. Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator. Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles. A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1