获取PPG信号诊断心脏相关参数

Rutuja Laulkar, Nivedita Daimiwal
{"title":"获取PPG信号诊断心脏相关参数","authors":"Rutuja Laulkar, Nivedita Daimiwal","doi":"10.1109/ISPTS.2012.6260945","DOIUrl":null,"url":null,"abstract":"Optical sensors that use photons as sensing elements are increasingly becoming important and relevant in the field of non-invasive diagnostics. The reason is that they are simple in construction, easy to use and relatively inexpensive in comparison with tools such as EEG, MRI and FMRI that can be used for research purposes without much investment. Among the various optical sensors available, the photoplethysmographic sensors that are capable of measuring the blood volumetric changes in subcutaneous vessels are used in present study. Objective is to diagnose different parameters like heart rate, blood pressure, respiratory rate, with the help of reflectance type PPG sensor. Real time PPG signal is captured from the sensor and with the help of microcontroller and RS 232 serial communication, the real time acquisition of PPG signal is observed on MATLAB. Detailed analysis of frequency spectrum of PPG signal shows a cardiac peak around 1Hz corresponding to 60 pulsations a minute and respiratory peak around 0.25 Hz corresponding to 15 inspiration/expiration cycles per minute. After the analysis of PPG signal, all the parameters are calculated and with the help of graphic user interface (GUI), all the parameters can simultaneously be seen on GUI window.","PeriodicalId":6431,"journal":{"name":"2012 1st International Symposium on Physics and Technology of Sensors (ISPTS-1)","volume":"52 1","pages":"274-277"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Acquisition of PPG signal for diagnosis of parameters related to heart\",\"authors\":\"Rutuja Laulkar, Nivedita Daimiwal\",\"doi\":\"10.1109/ISPTS.2012.6260945\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Optical sensors that use photons as sensing elements are increasingly becoming important and relevant in the field of non-invasive diagnostics. The reason is that they are simple in construction, easy to use and relatively inexpensive in comparison with tools such as EEG, MRI and FMRI that can be used for research purposes without much investment. Among the various optical sensors available, the photoplethysmographic sensors that are capable of measuring the blood volumetric changes in subcutaneous vessels are used in present study. Objective is to diagnose different parameters like heart rate, blood pressure, respiratory rate, with the help of reflectance type PPG sensor. Real time PPG signal is captured from the sensor and with the help of microcontroller and RS 232 serial communication, the real time acquisition of PPG signal is observed on MATLAB. Detailed analysis of frequency spectrum of PPG signal shows a cardiac peak around 1Hz corresponding to 60 pulsations a minute and respiratory peak around 0.25 Hz corresponding to 15 inspiration/expiration cycles per minute. After the analysis of PPG signal, all the parameters are calculated and with the help of graphic user interface (GUI), all the parameters can simultaneously be seen on GUI window.\",\"PeriodicalId\":6431,\"journal\":{\"name\":\"2012 1st International Symposium on Physics and Technology of Sensors (ISPTS-1)\",\"volume\":\"52 1\",\"pages\":\"274-277\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-03-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 1st International Symposium on Physics and Technology of Sensors (ISPTS-1)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISPTS.2012.6260945\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 1st International Symposium on Physics and Technology of Sensors (ISPTS-1)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPTS.2012.6260945","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

利用光子作为传感元件的光学传感器在非侵入性诊断领域越来越重要和相关。原因在于,与EEG、MRI和FMRI等工具相比,它们结构简单,使用方便,价格相对便宜,无需太多投资即可用于研究目的。在现有的各种光学传感器中,本研究使用的是能够测量皮下血管血容量变化的光容积脉搏波传感器。目的是利用反射式PPG传感器对心率、血压、呼吸频率等参数进行诊断。从传感器实时采集PPG信号,借助单片机和rs232串行通信,在MATLAB上观察PPG信号的实时采集。对PPG信号频谱的详细分析表明,心脏峰值在1Hz左右,对应每分钟60次脉动,呼吸峰值在0.25 Hz左右,对应每分钟15次吸气/呼气周期。对PPG信号进行分析后,计算出所有参数,并借助图形用户界面(GUI)在GUI窗口上同时显示所有参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Acquisition of PPG signal for diagnosis of parameters related to heart
Optical sensors that use photons as sensing elements are increasingly becoming important and relevant in the field of non-invasive diagnostics. The reason is that they are simple in construction, easy to use and relatively inexpensive in comparison with tools such as EEG, MRI and FMRI that can be used for research purposes without much investment. Among the various optical sensors available, the photoplethysmographic sensors that are capable of measuring the blood volumetric changes in subcutaneous vessels are used in present study. Objective is to diagnose different parameters like heart rate, blood pressure, respiratory rate, with the help of reflectance type PPG sensor. Real time PPG signal is captured from the sensor and with the help of microcontroller and RS 232 serial communication, the real time acquisition of PPG signal is observed on MATLAB. Detailed analysis of frequency spectrum of PPG signal shows a cardiac peak around 1Hz corresponding to 60 pulsations a minute and respiratory peak around 0.25 Hz corresponding to 15 inspiration/expiration cycles per minute. After the analysis of PPG signal, all the parameters are calculated and with the help of graphic user interface (GUI), all the parameters can simultaneously be seen on GUI window.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Gas sensing properties of the fluorine-doped tin oxide thin films Prepared by advanced spray pyrolysis Tailoring of optical band gap, morphology and surface wettability of bath deposited nanocrystalline ZnxCd(1−x)S thin films with incorporation of Zn for solar cell application Comparison of micro fabricated C and S bend shape SU-8 polymer waveguide of different bending diameters for maximum sensitivity A theoretical approach to study the temperature dependent performance of a SiC MESFET in sensor application. Effect of RE3+ (RE = Eu, Sm) ion doping on dielectric properties of nano-wollastonite synthesized by combustion method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1