基于完全开关状态分析的电压完整性死区补偿策略

Hongtao Fang, Hengdong Cui, Ronggang Ni
{"title":"基于完全开关状态分析的电压完整性死区补偿策略","authors":"Hongtao Fang, Hengdong Cui, Ronggang Ni","doi":"10.1109/ITECAsia-Pacific56316.2022.9942132","DOIUrl":null,"url":null,"abstract":"Three-phase voltage source inverters (VSIs) have been widely used in renewable energy conversion and motor drives, etc. However, dead-time, which is inevitable to prevent shoot-through of VSI in-phase legs, causes output fundamental voltage loss and low-order harmonic increases. In this paper, six short side non-zero voltage base vectors are found beside the six long side non-zero voltage base vectors in conventional space voltage vector plane when dead time is considered, which is not proposed previously. Then, by considering the amplitude and phase angle of twelve non-zero voltage base vectors, a dead time compensation (DTC) strategy for voltage integrity based on a complete switching state is proposed. Finally, both simulations and experiments are carried out based on the open-loop control to verify the effect of the proposed compensation strategy.","PeriodicalId":45126,"journal":{"name":"Asia-Pacific Journal-Japan Focus","volume":"116 1","pages":"1-6"},"PeriodicalIF":0.2000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel Dead-Time Compensation Strategy for Voltage Integrity Based on Complete Switching State Analysis\",\"authors\":\"Hongtao Fang, Hengdong Cui, Ronggang Ni\",\"doi\":\"10.1109/ITECAsia-Pacific56316.2022.9942132\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three-phase voltage source inverters (VSIs) have been widely used in renewable energy conversion and motor drives, etc. However, dead-time, which is inevitable to prevent shoot-through of VSI in-phase legs, causes output fundamental voltage loss and low-order harmonic increases. In this paper, six short side non-zero voltage base vectors are found beside the six long side non-zero voltage base vectors in conventional space voltage vector plane when dead time is considered, which is not proposed previously. Then, by considering the amplitude and phase angle of twelve non-zero voltage base vectors, a dead time compensation (DTC) strategy for voltage integrity based on a complete switching state is proposed. Finally, both simulations and experiments are carried out based on the open-loop control to verify the effect of the proposed compensation strategy.\",\"PeriodicalId\":45126,\"journal\":{\"name\":\"Asia-Pacific Journal-Japan Focus\",\"volume\":\"116 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asia-Pacific Journal-Japan Focus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITECAsia-Pacific56316.2022.9942132\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"AREA STUDIES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia-Pacific Journal-Japan Focus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITECAsia-Pacific56316.2022.9942132","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AREA STUDIES","Score":null,"Total":0}
引用次数: 0

摘要

三相电压源逆变器已广泛应用于可再生能源转换、电机驱动等领域。然而,为了防止VSI同相支路的通断,死区时间不可避免地会导致输出基频电压损失和低次谐波增加。本文在考虑死区时间的情况下,在传统的空间电压矢量平面中,在6个长边非零电压基矢量旁边找到6个短边非零电压基矢量,这是前人没有提出的。然后,考虑12个非零电压基矢量的幅值和相位角,提出了基于完全开关状态的电压完整性死区补偿策略。最后,基于开环控制进行了仿真和实验,验证了所提补偿策略的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel Dead-Time Compensation Strategy for Voltage Integrity Based on Complete Switching State Analysis
Three-phase voltage source inverters (VSIs) have been widely used in renewable energy conversion and motor drives, etc. However, dead-time, which is inevitable to prevent shoot-through of VSI in-phase legs, causes output fundamental voltage loss and low-order harmonic increases. In this paper, six short side non-zero voltage base vectors are found beside the six long side non-zero voltage base vectors in conventional space voltage vector plane when dead time is considered, which is not proposed previously. Then, by considering the amplitude and phase angle of twelve non-zero voltage base vectors, a dead time compensation (DTC) strategy for voltage integrity based on a complete switching state is proposed. Finally, both simulations and experiments are carried out based on the open-loop control to verify the effect of the proposed compensation strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
8
期刊最新文献
An Inertia Adjustment Control Strategy of Grid-Forming Electric Vehicle for V2G Application An Improved Control Strategy of PM-Assisted Synchronous Reluctance Machines Based on an Extended State Observer Comparison and evaluation of the thermal performance between SiC-MOSFET and Si-IGBT Analysis and Design of Passive Damping for LC-Equipped Permanent-Magnet Synchronous Machine Drive System Research on dynamic pricing strategy of electric material distribution vehicle based on master-slave game and multi-hot code
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1